中文
相关论文

相关论文: A Large Area Timing RPC

200 篇论文

High-time-resolution counters based on plastic scintillator with silicon photomultiplier (SiPM) readout have been developed for applications to high energy physics experiments for which relatively large-sized counters are required. We have…

The HL-LHC phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. To achieve this goal in a reasonable time scale the instantaneous luminosity would also increase by an order of…

仪器与探测器 · 物理学 2016-09-21 F. Lagarde , M. Gouzevitch , I. Laktineh , V. Buridon , X. Chen , C. Combaret , A. Eynard , L. Germani , G. Grenier , H. Mathez , L. Mirabito , A. Petrukhin , A. Steen , W. Tromeuraa , Y. Wang , A. Gongab , N. Moreau , C. de la Taille , F. Dulucqac , A. Cimmino , S. Crucy , A. Fagot , M. Gul , A. A. O. Rios , M. Tytgat , N. Zaganidisb , S. Aly , Y. Assran , A. Radi , A. Sayedc , G. Singhd , M. Abbrescia , G. Iaselli , M. Maggi , G. Pugliese , P. Verwilligene , W. Van Doninck , S. Colafranceschi , A. Sharmag , L. Benussi , S. Bianco , D. Piccolo , F. Primaverah , V. Bhatnagar , R. Kumari , A. Mehta , J. Singhi , A. Ahmad , W. Ahmed , H. M. I. Asghar , I. M. Awan , R. Hoorani , S. Muhammad , H. Shahzad , M. A. Shah , S. W. Cho , S. Y. Choi , B. Hong , M. H. Kang , K. S. Lee , J. H. Lim , S. K. Parkk , M. S. Kiml , S. Carpinteyro Bernardino , I. Pedraza , C. Uribe Estradam , S. Carrillo Moreno , F. Vazquez Valencian , L. M. Panto , S. Buontempo , N. Cavallo , M. Esposito , F. Fabozzi , G. Lanza , I. Orso , L. Lista , S. Meola , M. Merola , P. Paolucci , F. Thyssen , A. Braghieri , A. Magnani , P. Montagna , C. Riccardi , P. Salvini , I. Vai , P. Vituloq , Y. Ban , S. J. Qianr , M. Choi , Y. Choi , J. Goh , D. Kimt , A. Aleksandrov , R. Hadjiiska , P. Iaydjiev , M. Rodozov , S. Stoykova , G. Sultanov , M. Vutovau , A. Dimitrov , L. Litov , B. Pavlov , P. Petkovv , I. Bagaturia , D. Lomidzew , C. Avila , A. Cabrera , J. C. Sanabria , I. Crottyy , J. Vaitkusz

A plastic scintillator bar with dimensions 300 cm x 2.5 cm x 11 cm was exposed to a focused muon beam to study its light yield and timing characteristics as a function of position and angle of incidence. The scintillating light was read out…

仪器与探测器 · 物理学 2017-08-07 A. Blondel , D. Breton , A. Dubreuil , A. Khotyantsev , A. Korzenev , J. Maalmi , A. Mefodev , P. Mermod , E. Noah

A new-concept time projection chamber (TPC) using a commercial resistive sheet, sheet-resistor micro-TPC SR-microPIC, was developed and its performance was measured. SR-microTPC has the potential to create a more uniform electric field than…

The light yield, the time resolution and the efficiency of different types of scintillating tiles with direct Silicon Photomultiplier readout and instrumented with a customised front-end electronics have been measured at the Beam Test…

A new particle detector with sub-nanosecond time resolution capable of working in high-rate environment (rate capability of the order of $MHz/ cm^2$) is under developmnet. Semiconductive electrodes with resistivity $\rho$ up to $10^8…

A new type of resistive plate chamber (RPC) is under development using thin-film resistive electrodes based on diamond-like carbon (DLC). Planned to be put on the path of high-intensity low-momentum muon beam of the MEG II experiment, this…

仪器与探测器 · 物理学 2022-12-21 Atsushi Oya , Kei Ieki , Atsuhiko Ochi , Rina Onda , Wataru Ootani , Kensuke Yamamoto

The STAR Time Projection Chamber (TPC) is used to record collisions at the Relativistic Heavy Ion Collider (RHIC). The TPC is the central element in a suite of detectors that surrounds the interaction vertex. The TPC provides complete…

The intrinsic rate capability and the ageing properties of the Resistive Plate Chambers are closely related to the electrodes material and to the front-end electronics threshold. The development of a low noise pre-amplifier led us to…

The construction and characteristics of the cylindrical ion pulse ionization chamber (CIPIC) with a working volume of 3.2 L are described. The chamber is intended to register alpha-particles from the $^{222}$Rn and its daughter's decays in…

This paper proposes and evaluates a novel architecture for a low-power Time-to-Digital Converter with high resolution, optimized for both integration in multichannel chips and high rate operation (40 Mconversion/s/channel). This converter…

信号处理 · 电气工程与系统科学 2023-06-02 Florent Bouyjou

Resistive Plate Chamber (RPC) is one of the most commonly used detectors in high energy physics experiments for triggering and tracking because of its good efficiency ($\textgreater$~90\%) and time resolution ($\sim$~1-2~ns). Generally,…

仪器与探测器 · 物理学 2025-03-21 A. Sen , S. Mandal , S. Chatterjee , S. Gope , S. Das , S. Biswas

The limitation of the detection rate of standard bakelite resistive plate chambers (RPC) used as muon detectors in the LHC experiments has prevented the use of such detectors in the high rate regions in both CMS and ATLAS detectors. One…

仪器与探测器 · 物理学 2015-06-12 Y. Haddad , G. Grenier , I. Laktineh , N. Lumb , S. Cauwenbergh

Timing characteristics of two multigap RPCs were compared. One had four subgaps 0.3 mm wide and the other - two subgaps 0.6 mm wide. Specially developed electronics was used. Electronics resolution convoluted with measured charge spectra at…

高能物理 - 实验 · 物理学 2007-05-23 V. Ammosov , V. Gapienko , A. Ivanilov , A. Semak , Yu. Sviridov , E. Usenko , V. Zaets

We present recent results of an extensive aging test, performed at the CERN Gamma Irradiation Facility on two single--gap RPC prototypes, developed for the LHCb Muon System. With a method based on a model describing the behaviour of an RPC…

A muon telescope equipped with four Resistive Plate Chambers of 2 m$^{2}$ per plane was tested with the muon scattering tomography technique. The telescope was operated during several hours with high atomic number materials located at its…

A novel design of Resistive Plate Chambers (RPCs), using only a single resistive plate, is being proposed. Based on this design, two large size prototype chambers were constructed and were tested with cosmic rays and in particle beams. The…

仪器与探测器 · 物理学 2015-05-20 B. Bilki , F. Corriveau , B. Freund , C. Neubüser , Y. Onel , J. Repond , J. Schlereth , L. Xia

We address the determination of the time resolution for the $\rm 100~\mu m$ 4H-SiC PIN detectors fabricated by Nanjing University (NJU). The time response to $\rm \beta$ particles from a $\rm ^{90}$Sr source is investigated for the…

Performances of several single gap (gas gap 2 mm) prototype Resistive Plate Chambers (RPC) made of high resistive ({\rho} \sim 1010 - 1012 {\Omega} cm) bakelite, commercially available in India have been studied in recent times. To make the…