中文
相关论文

相关论文: A Large Area Timing RPC

200 篇论文

Resistive Plate Chambers (RPCs) featuring 1 mm gas volumes combined with high-pressure phenolic laminate (HPL) electrodes provide excellent timing resolution down to a few hundred picoseconds, along with spatial resolution on the order of a…

This paper reports on the performance of Resistive Plate Chambers (RPCs) as function of the gas flow rate through the chambers and of environmental conditions, such as atmospheric pressure, ambient temperature and air humidity. The chambers…

Single gap (gas gap 2 mm) bakelite Resistive Plate Chamber (RPC) modules of various sizes from 10 cm \times 10 cm to 1 m \times 1 m have been fabricated, characterized and optimized for efficiency and time resolution. Thin layers of…

仪器与探测器 · 物理学 2015-06-05 K. K. Meghna , A. Banerjee , S. Biswas , S. Bhattacharya , S. Bose , S. Chattopadhyay , G. Das , C. Marick , S. Saha , Y. P. Viyogi

Nowadays, commonly used Resistive Plate Chambers (RPCs) have counting rate capabilities of ~10E4Hz/cm2 and position resolutions of ~1cm. We have developed small prototypes of RPCs (5x5 and 10x10cm2) having rate capabilities of up to…

仪器与探测器 · 物理学 2015-06-26 C. Iacobaeus , P. Fonte , T. Francke , J. Ostling , V. Peskov , J. Rantanen , I. Rodionov

The Multigap Resistive Plate Chambers (MRPCs) are gas ionization detectors with multiple gas sub-gaps made of resistive electrodes. The high voltage (HV) is applied on the outer surfaces of outermost resistive plates only, while the…

仪器与探测器 · 物理学 2016-12-16 Moon Moon Devi , Naba K. Mondal , B. Satyanarayana , R. R. Shinde

A four-gap glass RPC with 0.3mm gap size was tested with hadron beam as a time-of-flight detector having a time resolution of ~ 100ps. A thickness of the detector together with front-end electronics is ~ 12mm. Results on time resolution…

高能物理 - 实验 · 物理学 2007-05-23 V. Ammosov , V. Gapienko , A. Semak , V. Senko , Yu. Sviridov , V. Zaets , E. Usenko

Resistive Plate Chambers (RPCs) exhibit a significant loss of efficiency for the detection of particles, when subjected to high particle fluxes. This rate limitation is related to the usually high resistivity of the resistive plates used in…

仪器与探测器 · 物理学 2015-09-08 M. Affatigato , U. Akgun , B. Bilki , F. Corriveau , B. Freund , N. Johnson , C. Neubueser , Y. Onel , J. Repond , L. Xia

Time of flight of a minimum ionizing particle along a fixed base has been measured with a 100 ps accuracy by means of a Dielectric Resistive Plate Chamber (DRPC) with 4 x 0.3 mm gas gaps. DRPC timing characteristics have been studied with…

仪器与探测器 · 物理学 2007-05-23 A. Akindinov , V. Golovin , A. Martemiyanov , V. Petrov , V. Plotnikov , A. Smirnitsky , K. Voloshin

A challenging goal of 20 ps for the total time resolution of the Multi-gap Resistive Plate Chambers (MRPCs) system has been recently addressed by high energy physics experiments. In order to meet this requirement, one should have a deeper…

仪器与探测器 · 物理学 2019-10-15 Fuyue Wang , Dong Han , Yi Wang , Pengfei Lyu , Yuanjing Li

A novel Resistive Plate Chamber (RPC) was designed with Diamond-Like Carbon (DLC) electrodes and performance studies were carried out for 384$\,\mathrm{\mu m}$ gap configuration with a $2\,\mathrm{cm}\times2\,\mathrm{cm}$ prototype. The use…

仪器与探测器 · 物理学 2024-01-25 Kei Ieki , Weiyuan Li , Atsuhiko Ochi , Rina Onda , Wataru Ootani , Atsushi Oya , Masato Takahashi , Kensuke Yamamoto

In the CBM (Compressed Baryonic Matter) experiment constructed at the Facility for Anti-proton and Ion Research (Fair) at GSI, Darmstadt, Germany, MRPC(Multi-gap Resistive Plate Chamber) is adopted to construct the large TOF…

In this study an array of eight 6 mm x 6 mm area SiPMs was coupled to the end of a long plastic scintillator counter which was exposed to a 2.5 GeV/c muon beam at the CERN PS. Timing characteristics of bars with dimensions 150 cm x 6 cm x 1…

This work reports a cost-effective, multi-parameter readout and data-acquisition system for a muon scattering tomography system based on Resistive Plate Chambers (RPCs). Initial test measurements with a prototype Resistive Plate Chamber…

仪器与探测器 · 物理学 2022-06-01 Subhendu Das , Sridhar Tripathy , Sandip Sarkar , Nayana Majumdar , Supratik Mukhopadhyay

An optimized design of a neutron detector based on timing RPCs (Resistive Plate Chambers) with boron-10 neutron converters is presented. The detector is composed of a stack of ten double gap RPCs with aluminium cathode plates coated on both…

仪器与探测器 · 物理学 2023-05-03 L. M. S. Margato , G. Canezin , A. Morozov , A. Blanco , J. Saraiva , L. Lopes , P. Fonte

A micro time-projection-chamber (micro-TPC) with a detection volume of 23*28*31 cm^3 was developed, and its fundamental performance was examined. The micro-TPC consists of a micro pixel chamber with a detection area of 31*31 cm^2 as a…

The Reactions with Relativistic Radioactive Beams (R$^3$B) collaboration of the Facility for Antiproton and Ion Research (FAIR) in Darmstadt, Germany, has constructed an experimental setup to perform fundamental studies of nuclear matter,…

The analog front-end electronics based on the constant fraction discrimination method is designed and optimized for the Multigap Resistive Plate Chamber (MRPC) timing measurements. The total time resolution of 40 ps has been obtained for 10…

仪器与探测器 · 物理学 2025-05-29 L. L. Kurchaninov , E. A. Ladygin , V. P. Ladygin , A. A. Semak

The Multigap Resistive Plate Chambers (MRPCs) provide excellent timing as well as position resolutions at relatively low cost. Therefore, they can be used in medical imaging applications such as PET where precise timing is a crucial…

仪器与探测器 · 物理学 2019-07-23 M. Nizam , B. Satyanarayana , R. R. Shinde , G. Majumder

Principles of operation, construction and first test results of a Dielectric Resistive Plate Chamber (DRPC) are described. The detector has shown stability of operation in the avalanche mode of gas amplfication within a wide range of…

仪器与探测器 · 物理学 2007-05-23 A. Akindinov , V. Golovin , A. Martemiyanov , V. Petrov , A. Smirnitskiy , K. Voloshin

As part of the Compact Muon Solenoid experiment Phase-II upgrade program, new Resistive Plate Chambers will be installed in the forward region. High background conditions are expected in this region during the high-luminosity phase of the…

仪器与探测器 · 物理学 2020-06-02 Sabino Meola