中文
相关论文

相关论文: A Large Area Timing RPC

200 篇论文

The HARP system of resistive plate chambers (RPCs) was designed to perform particle identification by the measurement of the difference in the time-of-flight of different particles. In previous papers an apparent discrepancy was shown…

In the new era of HL-LHC experiments, fast-timing detectors are emerging as critical tools for background rejection. Typical requirements include a temporal hit resolution of about 50 ps, a spatial resolution of around 12 $\mu$m, and…

Timing-pick up detectors with excellent timing resolutions are essential in many modern nuclear physics experiments. Aiming to develop a Time-Of-Flight system with precision down to about 10 ps, we have made a systematic study of the timing…

Numerical calculations have been performed to understand the reason for the observed non-uniform response of a Resistive Plate Chamber (RPC) in a few critical regions such as near edge spacers and corners of the device. In this context, the…

仪器与探测器 · 物理学 2016-09-23 Abhik Jash , Nayana Majumdar , Supratik Mukhopadhyay , Satyajit Saha , Subhasis Chattopadhyay

Resistive Plate Chambers (RPCs) are essential active media of large-scale experiments as part of the muon systems and (semi-)digital hadron calorimeters. Among the several outstanding issues associated with the RPCs, the loss of efficiency…

仪器与探测器 · 物理学 2023-07-19 Mehmet Tosun , Burak Bilki , Kutlu Kagan Sahbaz

The low cost and high resolution Multi-gap Resistive Plate Chamber (MRPC) opens up a new possibility to find an efficient alternative detector for the Time of Flight (TOF) based Positron Emission Tomography, where the sensitivity of the…

仪器与探测器 · 物理学 2015-06-22 A. Banerjee , A. Roy , S. Biswas , S. Chattopadhyay , G. Das , S. Pal

The Resistive Plate Chamber is a widely used detector in high energy physics. The operating potential of this chamber is determined by the optimisation of the efficiency and noise rate of the device. This optimisation is based on the…

仪器与探测器 · 物理学 2022-04-05 S. Pethuraj , G. Majumder , K. C. Ravindran , B. Satyanarayana , Umesh L

Optimization of spacer and gas distribution inside glass resistive plate chamber (RPC) is reported. Simulation studies demonstrate improvements on the gas flow velocity homogeneity and lower vorticity inside the gas chamber. The optimized…

仪器与探测器 · 物理学 2022-01-05 L. Mao , F. Lagarde , J. Guo , X. Wang , J. Li , Q. Shen , J. Zhu , H. Yang

Multi-gap Resistive Plate Chambers (MRPCs) with multi-strip readout are considered to be the optimal detector candidate for the Time-of-Flight (ToF) wall in the Compressed Baryonic Matter (CBM) experiment. In the R&D phase MRPCs with…

仪器与探测器 · 物理学 2016-11-23 I. Deppner , N. Herrmann , J. Frühauf , M. Kiš , P. Lyu , P. -A. Loizeau , L. Shi , C. Simon , Y. Wang , B. Xie

First of its kind, the barrel section of the MIP Timing Detector is a large area timing detector based on LYSO:Ce crystals and SiPMs which are required to operate in an unprecedentedly harsh radiation environment (up to an integrated…

仪器与探测器 · 物理学 2025-08-14 F. Addesa , P. Akrap , A. Albert , B. Allmond , T. Anderson , J. Babbar , D. Baranyai , P. Barria , C. Basile , A. Benaglia , A. Benato , M. Benettoni , M. Besancon , N. Bez , S. Bhattacharya , R. Bianco , D. Blend , A. Boletti , A. Bornheim , R. Bugalho , A. Bulla , B. Cardwell , R. Carlin , M. Casarsa , F. Cetorelli , F. Cossutti , B. Cox , G. Da Molin , F. De Guio , K. De Leo , F. De Riggi , P. Debbins , D. Del Re , R. Delli Gatti , J. Dervan , P. Devouge , K. Dreimanis , O. M. Eberlins , F. Errico , E. Fernandez , W. Funk , A. Gaile , M. Gallinaro , R. Gargiulo , R. Gerosa , A. Ghezzi , B. Gyongyosi , Z. Hao , A. H. Heering , Z. Hu , R. Isocrate , M. Jose , A. Karneyeu , M. S. Kim , A. Krishna , B. Kronheim , O. K. Köseyan , A. Ledovskoy , L. Li , Z. Li , V. Lohezic , F. Lombardi , M. T. Lucchini , M. Malberti , Y. Mao , Y. Maravin , B. Marzocchi , D. Mazzaro , R. Menon Raghunandanan , P. Meridiani , C. Munoz Diaz , Y. Musienko , S. Nargelas , L. L. Narváez , C. Neu , G. Organtini , T. Orimoto , D. Osite , M. Paganoni , S. Palluotto , C. Palmer , N. Palmeri , F. Pandolfi , R. Paramatti , T. Pauletto , A. Perego , G. Pikurs , G. Pizzati , R. Plese , C. Quaranta , G. Reales Gutiérrez , N. Redaelli , S. Ronchi , R. Rossin , M. Ö. Sahin , F. Santanastasio , I. Schmidt , D. Sidiropoulos Kontos , T. Sievert , R. Silva , P. Simmerling , L. Soffi , P. Solanki , G. Sorrentino , M. Spiropulu , N. R. Strautnieks , X. Sun , D. D. Szabo , T. Tabarelli de Fatis , G. Tamulaitis , R. Taylor , M. Titov , M. Tosi , G. Trabucco , A. Tsirou , C. Tully , M. Turcato , B. Ujvari , J. Varela , F. Veronese , V. Vladimirov , J. Wang , M. Wayne , S. White , Z. Wu , J. W. Wulff , R. A. Wynne , L. Zhang , M. Zhang , G. Zilizi

The Multi-gap Resistive Plate Chamber (MRPC) is an advanced form of Resistive Plate Chamber (RPC) detector where the gas gap is divided into sub-gaps. MRPCs are known for their good time resolution and detection efficiency for charged…

仪器与探测器 · 物理学 2018-08-15 Rajesh Ganai , Mitali Mondal , Shaifali Mehta , Zubayer Ahammed , Subhasis Chattopadhyay

The multi-gap resistive plate chambers (MRPCs) will be used as the Time-of-Flight (ToF) system in the Solenoidal Large Intensity Device (SoLID). The time resolution required by the experiment for the MRPC system is 20 ps in order to make a…

仪器与探测器 · 物理学 2020-05-11 Fuyue Wang , Dong Han , Yi Wang

The time resolution of Multigap Resistive Plate Counters (MRPCs) to $511$ keV gamma rays has been investigated using a $^{22}$Na source and four detectors. The MRPCs time resolution has been derived from the Time-of-Flight information,…

仪器与探测器 · 物理学 2015-12-09 G. Belli , M. Gabusi , G. Musitelli , R. Nardò , S. P. Ratti , A. Tamborini , P. Vitulo

This paper reports on detailed measurements of the performance of Resistive Plate Chambers in a proton beam with variable intensity. Short term effects, such as dead time, are studied using consecutive events. On larger time scales, for…

仪器与探测器 · 物理学 2009-06-25 B. Bilki , J. Butler , E. May , G. Mavromanolakis , E. Norbeck , J. Repond , D. Underwood , L. Xia , Q. Zhang

We have systematically studied the transmission of electrical signals along several 2-strip Resistive Plate Chambers (RPCs) in the frequency range $f=0.1-3.5$GHz. Such a range was chosen to fully cover the bandwidth associated to the very…

仪器与探测器 · 物理学 2015-03-18 Diego Gonzalez-Diaz , Huangshan Chen , Yi Wang

We have demonstrated that small gap (0.1 to 0.4 mm) RPCs made of low resistivity materials (less than 1E8 Ohm.cm) can operate at counting rates of up to 1E5 Hz/mm2 with position resolutions better than 50 micrometer. Results of preliminary…

仪器与探测器 · 物理学 2009-11-07 T. Francke , P. Fonte , V. Peskov , J. Rantanen

Most of the time-of-flight systems as well as the fast interaction trigger detectors have large surfaces and the principal requirements for the above mentioned detectors is a good time resolution of the order 100-200ps. The easiest solution…

仪器与探测器 · 物理学 2024-01-18 Varlen Grabski

This paper has the purpose to study the rate capability of the Resistive Plate Chamber, RPC, starting from the basic physics of this detector. The effect of different working parameters determining the rate capability is analysed in detail,…

An X-ray detector will be presented that is the combination of a segmented ionization chamber featuring one-dimensional spatial resolution integrated with an intelligent ADC front-end, multi DSP processing and embedded PC platform. This…

仪器与探测器 · 物理学 2010-01-26 Francesco Voltolina , Ralf H. Menk , Sergio Carrato

A pico-second timing (PIST) front-end electronic chip has been developed using $55~\mathrm{nm}$ CMOS technology for future electron-positron collider experiments (namely Higgs factories). Extensive tests have been performed to evaluate the…

仪器与探测器 · 物理学 2024-02-06 Xin Xia , Dejing Du , Xiaoshan Jiang , Yong Liu , Bo Lu , Junguang Lyu , Baohua Qi , Manqi Ruan , Xiongbo Yan