我们给出了在 CERN Gamma Irradiation Facility 对两个为 LHCb Muon System 开发的单气隙 RPC 原型进行广泛老化测试的最新结果。基于描述高粒子通量条件下 RPC 行为的模型方法,我们在三年间周期性测量了两个 RPC 原型的电极电阻 R:观察到 R 随时间自发大幅增长,从约 2 MOhm 初始值增至超过 250 MOhm。同时也发现相应的 RPC 速率能力退化,从超过 3 kHz/cm2 降至低于 0.15 kHz/cm2。

关键词

引用

@article{arxiv.physics/0302077,
  title  = {New results from an extensive aging test on bakelite Resistive Plate Chambers},
  author = {Giovanni Carboni and Gianmaria Collazuol and Stefano De Capua and Danilo Domenici and Gerardo Ganis and Roberto Messi and Giovanni Passaleva and Emanuele Santovetti and Michele Veltri},
  journal= {arXiv preprint arXiv:physics/0302077},
  year   = {2009}
}

备注

6 pages, 7 figures, presented at Siena 2002, 8th Topical Seminar on Innovative Particle and Radiation Detectors 21-24 October 2002, Siena, Italy