ALICE缪子鉴别器由72个单气隙胶木阻性板室组成,自2009年以来一直在最大雪崩模式下运行(甄别阈值:7 mV,无放大),使用四氟乙烷/异丁烷/六氟化硫混合气体,承受的计数率约为数十Hz/cm^2。本次报告将讨论该RPC系统的长期性能和稳定性,包括效率、暗电流和暗计数率。将介绍对探测器上观察到的潜在老化迹象的评估,并总结遇到的最常见硬件问题。