中文
相关论文

相关论文: A Motion Compensation Approach for Oral and Maxill…

200 篇论文

Purpose: The long scan times of quantitative MRI techniques make motion artifacts more likely. For MR-Fingerprinting-like approaches, this problem can be addressed with self-navigated retrospective motion correction based on reconstructions…

医学物理 · 物理学 2025-06-18 Elisa Marchetto , Sebastian Flassbeck , Andrew Mao , Jakob Assländer

Intravital X-ray microscopy (XRM) in preclinical mouse models is of vital importance for the identification of microscopic structural pathological changes in the bone which are characteristic of osteoporosis. The complexity of this method…

Motion free reconstruction of compressively sampled cardiac perfusion MR images is a challenging problem. It is due to the aliasing artifacts and the rapid contrast changes in the reconstructed perfusion images. In addition to the…

图像与视频处理 · 电气工程与系统科学 2019-04-11 Abdul Haseeb Ahmed , Ijaz M. Qureshi

Objective. Motion artifacts in brain MRI, mainly from rigid head motion, degrade image quality and hinder downstream applications. Conventional methods to mitigate these artifacts, including repeated acquisitions or motion tracking, impose…

计算机视觉与模式识别 · 计算机科学 2026-01-16 Mojtaba Safari , Shansong Wang , Qiang Li , Zach Eidex , Richard L. J. Qiu , Chih-Wei Chang , Hui Mao , Xiaofeng Yang

Magnetic Resonance Imaging (MRI) is highly susceptible to motion artifacts due to the extended acquisition times required for k-space sampling. These artifacts can compromise diagnostic utility, particularly for dynamic imaging. We propose…

图像与视频处理 · 电气工程与系统科学 2025-07-04 Frederic Wang , Jonathan I. Tamir

Motion artefacts created by patient motion during an MRI scan occur frequently in practice, often rendering the scans clinically unusable and requiring a re-scan. While many methods have been employed to ameliorate the effects of patient…

图像与视频处理 · 电气工程与系统科学 2020-06-30 Michael Rotman , Rafi Brada , Israel Beniaminy , Sangtae Ahn , Christopher J. Hardy , Lior Wolf

Metallic implants introduce severe artifacts in CT images, which degrades the image quality. It is an effective method to reduce metal artifacts by replacing the metal affected projection with the forward projection of a prior image. How to…

医学物理 · 物理学 2014-09-05 Yanbo Zhang , Xuanqian Mou

Low-dose dental cone beam computed tomography (CBCT) has been increasingly used for maxillofacial modeling. However, the presence of metallic inserts, such as implants, crowns, and dental filling, causes severe streaking and shading…

图像与视频处理 · 电气工程与系统科学 2022-02-09 Chang Min Hyun , Taigyntuya Bayaraa , Hye Sun Yun , Tae Jun Jang , Hyoung Suk Park , Jin Keun Seo

The presence of motion artifacts in magnetic resonance imaging (MRI) scans poses a significant challenge, where even minor patient movements can lead to artifacts that may compromise the scan's utility.This paper introduces MAsked MOtion…

图像与视频处理 · 电气工程与系统科学 2024-11-05 Lennart Alexander Van der Goten , Jingyu Guo , Kevin Smith

We address the problem of reconstructing high quality images from undersampled MRI data. This is a challenging task due to the highly ill-posed nature of the problem. In particular, in dynamic MRI scans, the interaction between the target…

计算机视觉与模式识别 · 计算机科学 2020-04-10 Angelica I. Aviles-Rivero , Noémie Debroux , Guy Williams , Martin J. Graves , Carola-Bibiane Schonlieb

Motion artifacts are a primary source of magnetic resonance (MR) image quality deterioration with strong repercussions on diagnostic performance. Currently, MR motion correction is carried out either prospectively, with the help of motion…

计算机视觉与模式识别 · 计算机科学 2019-11-26 Karim Armanious , Sergios Gatidis , Konstantin Nikolaou , Bin Yang , Thomas Küstner

Purpose: To develop a computationally viable autofocus method for estimating 3D rigid motion in MR imaging. Theory and Methods: The proposed method, REACT, assumes a piecewise-constant motion trajectory and estimates the rigid motion…

图像与视频处理 · 电气工程与系统科学 2026-03-25 Kwang Eun Jang , Dwight G. Nishimura

Purpose: To improve upon Extreme MRI, a recently proposed method by Ong Et al. for reconstructing high spatiotemporal resolution, 3D non-Cartesian acquisitions by incorporating motion compensation into these reconstructions using an…

医学物理 · 物理学 2022-05-03 Zachary Miller , Luis Torres , Sean Fain , Kevin Johnson

X-ray computed tomography (CT) reconstructs the internal morphology of a three dimensional object from a collection of projection images, most commonly using a single rotation axis. However, for objects containing dense materials like…

图像与视频处理 · 电气工程与系统科学 2024-06-27 Diyu Yang , Craig A. J. Kemp , Soumendu Majee , Gregery T. Buzzard , Charles A. Bouman

Motion artifacts in Magnetic Resonance Imaging (MRI) are one of the frequently occurring artifacts due to patient movements during scanning. Motion is estimated to be present in approximately 30% of clinical MRI scans; however, motion has…

图像与视频处理 · 电气工程与系统科学 2024-05-29 Zhifeng Chen , Kamlesh Pawar , Kh Tohidul Islam , Himashi Peiris , Gary Egan , Zhaolin Chen

We propose a novel scene-segmentation-based exposure compensation method for multi-exposure image fusion (MEF) based tone mapping. The aim of MEF-based tone mapping is to display high dynamic range (HDR) images on devices with limited…

计算机视觉与模式识别 · 计算机科学 2024-10-29 Yuma Kinoshita , Hitoshi Kiya

Respiratory motion can cause strong blurring artifacts in the reconstructed image during MR acquisition. These artifacts become more prominent when use in the presence of undersampled data. Recently, compressed sensing (CS) is developed as…

图像与视频处理 · 电气工程与系统科学 2019-04-10 Abdul Haseeb Ahmed , Ijaz M. Qureshi , Jawad Ali Shah , Hammad Omer

Efficient compression of 360-degree video content requires the application of advanced motion models for interframe prediction. The Motion Plane Adaptive (MPA) motion model projects the frames on multiple perspective planes in the 3D space.…

图像与视频处理 · 电气工程与系统科学 2025-04-01 Marina Ritthaler , Andy Regensky , André Kaup

Motion artifacts present in magnetic resonance imaging (MRI) can seriously interfere with clinical diagnosis. Removing motion artifacts is a straightforward solution and has been extensively studied. However, paired data are still heavily…

图像与视频处理 · 电气工程与系统科学 2024-12-12 Jiahua Xu , Dawei Zhou , Lei Hu , Jianfeng Guo , Feng Yang , Zaiyi Liu , Nannan Wang , Xinbo Gao

Motion-related artifacts are inevitable in Magnetic Resonance Imaging (MRI) and can bias automated neuroanatomical metrics such as cortical thickness. These biases can interfere with statistical analysis which is a major concern as motion…

图像与视频处理 · 电气工程与系统科学 2025-06-11 Charles Bricout , Samira Ebrahimi Kahou , Sylvain Bouix