相关论文: An Efficient Nonlinear Beamformer Based on P^{th} …
Photoacoustic imaging (PAI) is an emerging biomedical imaging modality capable of providing both high contrast and high resolution of optical and UltraSound (US) imaging. When a short duration laser pulse illuminates the tissue as a target…
Linear-array based photoacoustic images are reconstructed using the conventional delay-and-sum (DAS) beamforming method. Although the DAS beamformer is well suited for PA image formation, reconstructed images are often afflicted by noises,…
In Photoacoustic imaging (PA), Delay-and-Sum (DAS) beamformer is a common beamforming algorithm having a simple implementation. However, it results in a poor resolution and high sidelobes. To address these challenges, a new algorithm namely…
Photoacoustic imaging (PAI) is an emerging medical imaging modality capable of providing high spatial resolution of Ultrasound (US) imaging and high contrast of optical imaging. Delay-and-Sum (DAS) is the most common beamforming algorithm…
Delay-and-Sum (DAS) beamformer is the most common beamforming algorithm in Photoacoustic imaging (PAI) due to its simple implementation and real time imaging. However, it provides poor resolution and high levels of sidelobe. A new algorithm…
A new development in photoacoustic (PA) imaging has been the use of compact, portable and low-cost laser diodes (LDs), but LD-based PA imaging suffers from low signal intensity recorded by the conventional transducers. A common method to…
Delay and sum (DAS) is the most common beamforming algorithm in linear-array photoacoustic imaging (PAI) as a result of its simple implementation. However, it leads to a low resolution and high sidelobes. Delay multiply and sum (DMAS) was…
Delay-and-Sum (DAS) is the most common algorithm used in photoacoustic (PA) image formation. However, this algorithm results in a reconstructed image with a wide mainlobe and high level of sidelobes. Minimum variance (MV), as an adaptive…
In Photoacoustic imaging (PAI), the most prevalent beamforming algorithm is delay-and-sum (DAS) due to its simple implementation. However, it results in a low quality image affected by the high level of sidelobes. Coherence factor (CF) can…
Typically, an ultrasound flow imaging system employs the conventional delay and sum (DAS) beamformer due to its inherent low complexity. But the conventional DAS technique offers poor contrast, low imaging resolution, and limited…
In Photoacoustic imaging, Delay-and-Sum (DAS) algorithm is the most commonly used beamformer. However, it leads to a low resolution and high level of sidelobes. Delay-Multiply-and-Sum (DMAS) was introduced to provide lower sidelobes…
One of the common algorithms used to reconstruct photoacoustic (PA) images is the non-adaptive Delay-and-Sum (DAS) beamformer. However, the quality of the reconstructed PA images obtained by DAS is not satisfying due to its high level of…
Photoacoustic imaging (PAI) has been applied to many biomedical applications over the past decades. However, the received PA signal usually suffers from poor signal-to-noise ratio (SNR). Conventional solution of employing higher-power…
Photoacoustic imaging (PAI) is a promising medical imaging modality providing the spatial resolution of ultrasound (US) imaging and the contrast of pure optical imaging. For linear-array PAI, a beamformer has to be used as the…
Delay-and-sum (DAS) algorithms are widely used for beamforming in linear array photoacoustic imaging systems and are characterized by fast execution. However, these algorithms suffer from various drawbacks like low resolution, low contrast,…
Photoacoustic imaging (PAI), is a promising medical imaging technique that provides the high contrast of the optical imaging and the resolution of ultrasound (US) imaging. Among all the methods, Three-dimensional (3D) PAI provides a high…
In Ultrasound (US) imaging, Delay and Sum (DAS) is the most common beamformer, but it leads to low quality images. Delay Multiply and Sum (DMAS) was introduced to address this problem. However, the reconstructed images using DMAS still…
The quality of the reconstructed photoacoustic image largely depends on the amount of photoacoustic (PA) boundary data available, which in turn is proportional to the number of detectors employed. In case of limited data (owing to less…
Power Doppler ultrasound is in widespread clinical use for non-invasive vascular imaging but the most common current method - Delay and Sum (DAS) beamforming - suffers from limited resolution and high side-lobes. Here we propose the…
This paper aims to facilitate more practical NLOS imaging by reducing the number of samplings and scan areas. To this end, we introduce a phasor-based enhancement network that is capable of predicting clean and full measurements from noisy…