中文
相关论文

相关论文: Krypton assay in xenon at the ppq level using a ga…

200 篇论文

We extend our technique for observing very small concentrations of impurities in xenon gas to the problem of krypton detection. We use a conventional mass spectrometer to identify the krypton content of the xenon, but we improve the…

天体物理仪器与方法 · 物理学 2015-03-19 A. Dobi , C. G. Davis , C. Hall , T. Langford , S. Slutsky , Y. R. Yen

A new method for measuring trace amounts of krypton in xenon using a cold trap with a residual gas analyzer has been developed, which achieves an increased sensitivity by temporarily reducing the pumping speed while expending a minimal…

仪器与探测器 · 物理学 2015-06-12 Ethan Brown , Stephan Rosendahl , Christian Huhmann , Christian Weinheimer , Hans Kettling

The XENON1T experiment aims for the direct detection of dark matter in a cryostat filled with 3.3 tons of liquid xenon. In order to achieve the desired sensitivity, the background induced by radioactive decays inside the detector has to be…

仪器与探测器 · 物理学 2017-05-09 XENON Collaboration , E. Aprile , J. Aalbers , F. Agostini , M. Alfonsi , F. D. Amaro , M. Anthony , F. Arneodo , P. Barrow , L. Baudis , B. Bauermeister , M. L. Benabderrahmane , T. Berger , P. A. Breur , A. Brown , E. Brown , S. Bruenner , G. Bruno , R. Budnik , L. Bütikofer , J. Calvén , J. M. R. Cardoso , M. Cervantes , D. Cichon , D. Coderre , A. P. Colijn , J. Conrad , J. P. Cussonneau , M. P. Decowski , P. de Perio , P. Di Gangi , A. Di Giovanni , S. Diglio , E. Duchovni , G. Eurin , J. Fei , A. D. Ferella , A. Fieguth , D. Franco , W. Fulgione , A. Gallo Rosso , M. Galloway , F. Gao , M. Garbini , C. Geis , L. W. Goetzke , L. Grandi , Z. Greene , C. Grignon , C. Hasterok , E. Hogenbirk , R. Itay , B. Kaminsky , G. Kessler , A. Kish , H. Landsman , R. F. Lang , D. Lellouch , L. Levinson , M. Le Calloch , Q. Lin , S. Lindemann , M. Lindner , J. A. M. Lopes A. Manfredini , I. Maris , T. Marrodán Undagoitia , J. Masbou , F. V. Massoli , D. Masson , D. Mayani , Y. Meng , M. Messina , K. Micheneau , B. Miguez , A. Molinario , M. Murra , J. Naganoma , K. Ni , U. Oberlack , S. E. A. Orrigo , P. Pakarha , B. Pelssers , R. Persiani , F. Piastra , J. Pienaar , M. -C. Piro , V. Pizzella , G. Plante , N. Priel , L. Rauch , S. Reichard , C. Reuter , A. Rizzo , S. Rosendahl , N. Rupp , R. Saldanha , J. M. F. dos Santos , G. Sartorelli , M. Scheibelhut , S. Schindler , J. Schreiner , M. Schumann , L. Scotto Lavina , M. Selvi , P. Shagin , E. Shockley , M. Silva , H. Simgen , M. v. Sivers , A. Stein , D. Thers , A. Tiseni , G. Trinchero , C. Tunnell , N. Upole , H. Wang , Y. Wei , C. Weinheimer , J. Wulf , J. Ye , Y. Zhang , I. Cristescu

A novel online distillation technique was developed for the XENON1T dark matter experiment to reduce intrinsic background components more volatile than xenon, such as krypton or argon, while the detector was operating. The method is based…

仪器与探测器 · 物理学 2022-06-15 E. Aprile , K. Abe , F. Agostini , S. Ahmed Maouloud , M. Alfonsi , L. Althueser , E. Angelino , J. R. Angevaare , V. C. Antochi , D. Antón Martin , F. Arneodo , L. Baudis , A. L. Baxter , L. Bellagamba , A. Bernard , R. Biondi , A. Bismark , A. Brown , S. Bruenner , G. Bruno , R. Budnik , C. Capelli , J. M. R. Cardoso , D. Cichon , B. Cimmino , M. Clark , A. P. Colijn , J. Conrad , J. J. Cuenca-García , J. P. Cussonneau , V. D'Andrea , M. P. Decowski , P. Di Gangi , S. Di Pede , A. Di Giovanni , R. Di Stefano , S. Diglio , A. Elykov , S. Farrell , A. D. Ferella , H. Fischer , S. Form , W. Fulgione , P. Gaemers , R. Gaior , M. Galloway , F. Gao , R. Glade-Beucke , L. Grandi , J. Grigat , A. Higuera , C. Hils , K. Hiraide , L. Hoetzsch , J. Howlett , C. Huhmann , M. Iacovacci , Y. Itow , J. Jakob , F. Joerg , N. Kato , P. Kavrigin , S. Kazama , M. Kobayashi , G. Koltman , A. Kopec , H. Landsman , R. F. Lang , L. Levinson , I. Li , S. Liang , S. Lindemann , M. Lindner , K. Liu , F. Lombardi , J. Long , J. A. M. Lopes , Y. Ma , C. Macolino , J. Mahlstedt , A. Mancuso , L. Manenti , A. Manfredini , F. Marignetti , T. Marrodán Undagoitia , K. Martens , J. Masbou , D. Masson , E. Masson , S. Mastroianni , M. Messina , K. Miuchi , K. Mizukoshi , A. Molinario , S. Moriyama , K. Morå , Y. Mosbacher , M. Murra , K. Ni , U. Oberlack , J. Palacio , R. Peres , J. Pienaar , M. Pierre , V. Pizzella , G. Plante , J. Qi , J. Qin , D. Ramírez García , S. Reichard , A. Rocchetti , N. Rupp , L. Sanchez , J. M. F. dos Santos , G. Sartorelli , J. Schreiner , D. Schulte , H. Schulze Eißing , M. Schumann , L. Scotto Lavina , M. Selvi , F. Semeria , P. Shagin , E. Shockley , M. Silva , H. Simgen , A. Takeda , P. -L. Tan , A. Terliuk , C. Therreau , D. Thers , F. Toschi , G. Trinchero , C. Tunnell , F. Tönnies , K. Valerius , G. Volta , Y. Wei , C. Weinheimer , M. Weiss , D. Wenz , J. Westermann , C. Wittweg , T. Wolf , Z. Xu , M. Yamashita , L. Yang , J. Ye , L. Yuan , G. Zavattini , Y. Zhang , M. Zhong , T. Zhu , J. P. Zopounidis

A high performance distillation system to remove krypton from xenon was constructed, and a purity level of Kr/Xe = $\sim 3 \times 10^{-12}$ was achieved. This development is crucial in facilitating high sensitivity low background…

An efficient cryogenic distillation system was designed and constructed for PandaX-4T dark matter detector based on the McCabe-Thiele (M-T) method and the conservation of mass and energy. This distillation system is designed to reduce the…

Krypton-85 is an anthropogenic beta-decaying isotope which produces low energy backgrounds in dark matter and neutrino experiments, especially those based upon liquid xenon. Several technologies have been developed to reduce the Kr…

仪器与探测器 · 物理学 2017-04-26 D. Yu. Akimov , A. I. Bolozdynya , A. A. Burenkov , C. Hall , A. G. Kovalenko , V. V. Kuzminov , G. E. Simakov

The Large Underground Xenon (LUX) experiment operates at the Sanford Underground Research Facility to detect nuclear recoils from the hypothetical Weakly Interacting Massive Particles (WIMPs) on a liquid xenon target. Liquid xenon typically…

Ultra-sensitive quantification of trace radioactive krypton-85 is essential for low-background experiments, particularly for next-generation searches of galactic dark matter and neutrino physics using xenon-based time projection chambers…

仪器与探测器 · 物理学 2025-09-17 Matteo Guida , Ying-Ting Lin , Hardy Simgen

We have developed an atom trap trace analysis (ATTA) system to measure Kr in Xe at the part per trillion (ppt) level, a prerequisite for the sensitivity achievable with liquid xenon dark matter detectors beyond the current generation. Since…

原子物理 · 物理学 2013-09-30 Elena Aprile , Taehyun Yoon , Andre Loose , Luke W. Goetzke , Tanya Zelevinsky

An online cryogenic distillation system for the removal of krypton and radon from xenon was designed and constructed for PandaX-4T, a highly sensitive dark matter detection experiment. The krypton content in a commercial xenon product is…

We report on the development and performance of a high-sensitivity purity-analysis technique for gaseous xenon. The gas is sampled at macroscopic pressure from the system of interest using a UHV leak valve. The xenon present in the sample…

仪器与探测器 · 物理学 2011-05-09 D. S. Leonard , A. Dobi , C. Hall , L. Kaufman , T. Langford , S. Slutsky , Y. R. Yen

Acrylic is a popular structural material in experiments requiring low background because of its radio-purity, machinability, and mechanical strength. However, its porosity may cause significant gas absorption and influence the detector…

仪器与探测器 · 物理学 2022-06-01 Heng Lin , Kaixiang Ni , Haiyan Du , Ke Han , Xiangdong Ji , Tao Li , Lingyin Luo , Shaobo Wang , Xiyv Yan , Xinning Zeng , Wenming Zhang

The krypton electroluminescence yield was studied, at room temperature, as a function of electric field in the gas scintillation gap. A large area avalanche photodiode has been used to allow the simultaneous detection of the…

仪器与探测器 · 物理学 2021-02-02 R. D. P. Mano , C. A. O. Henriques , F. D. Amaro , C. M. B. Monteiro

We have developed an efficient cryogenic system with heat exchange and associated gas purification system, as a prototype for the XENON1T experiment. The XENON1T detector will use about 3 ton of liquid xenon (LXe) at a temperature of 175K…

We report a demonstration of the scalability of optically transparent xenon in the solid phase for use as a particle detector above a kilogram scale. We employed a cryostat cooled by liquid nitrogen combined with a xenon purification and…

仪器与探测器 · 物理学 2015-09-02 J. Yoo , H. Cease , W. F. Jaskierny , D. Markley , R. B. Pahlka , D. Balakishiyeva , T. Saab , M. Filipenko

We propose a new concept for a very low background multi-ton liquid xenon Dark Matter experiment. The detector consists of two concentric spheres and a charge readout device in the centre. Xenon between the two spheres forms a self-shield…

Measuring the argon purity is critical for all Ar-based rare event research experiments. Mass spectrometry is typically used to assess the uranium and thorium contamination in samples of the materials used to build low-background detectors;…

仪器与探测器 · 物理学 2023-03-03 R. Santorelli , A. I. Barrado Olmedo , E. Conde Vilda , M. Fernandez Diaz , V. Pesudo , L. Romero

The radioactive isomer $^{83\mathrm{m}}$Kr has many properties that make it very useful for various applications. Its low energy decay products, like conversion, shake-off and Auger electrons as well as X- and $\gamma$-rays are used for…

天体物理仪器与方法 · 物理学 2014-12-24 S. Rosendahl , K. Bokeloh , E. Brown , I. Cristescu , A. Fieguth , C. Huhmann , O. Lebeda , C. Levy , M. Murra , S. Schneider , D. Vénos , C. Weinheimer

The possibility of measuring the 85Kr activity with a liquid scintillation spectrometer (LSS) by registering the scintillations in krypton was investigated. It was found that at partial pressure of krypton less than atmospheric, the…

仪器与探测器 · 物理学 2015-10-13 E. G. Tertyshnik , V. N. Ivanov , E. S. Abduragimov
‹ 上一页 1 2 3 10 下一页 ›