相关论文: Achieving ultra-low and -uniform residual magnetic…
An increasing number of measurements in fundamental and applied physics rely on magnetically shielded environments with sub nano-Tesla residual magnetic fields. State of the art magnetically shielded rooms (MSRs) consist of up to seven…
We present the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute which features an interior cubic volume with each side of length 2.92m, thus providing an accessible space of 25m3. The MSR has 87…
We present a coil system designed to generate a highly uniform magnetic field for the n2EDM experiment at the Paul Scherrer Institute. It consists of a main $B_0$ coil and a set of auxiliary coils mounted on a cubic structure with a side…
The n2EDM experiment at the Paul Scherrer Institute aims to conduct a high-sensitivity search for the electric dipole moment of the neutron. Magnetic stability and control are achieved through a combination of passive shielding, provided by…
A versatile and portable magnetically shielded room with a field of (700 \pm 200) pT within a central volume of 1m x 1m x 1m and a field gradient less than 300 pT/m is described. This performance represents more than a hundred-fold…
We present a novel Active Magnetic Shield (AMS), designed and implemented for the n2EDM experiment at the Paul Scherrer Institute. The experiment will perform a high-sensitivity search for the electric dipole moment of the neutron.…
A magnetic coil operated at cryogenic temperatures is used to produce spatial, relative field gradients below 6 ppm/cm, stable for several hours. The apparatus is a prototype of the magnetic components for a neutron electric dipole moment…
We present a novel method for extracting the energy spectrum of ultracold neutrons from magnetically induced spin depolarization measurements using the n2EDM apparatus. This method is also sensitive to the storage properties of the…
We report on the performance of a Magnetically Shielded Room (MSR) intended for next level $^3$He/$^{129}$Xe co-magnetometer experiments which require improved magnetic conditions. The MSR consists of three layers of Mu-metal with a…
We report on the strategy used to optimize the sensitivity of our search for a neutron electric dipole moment at the Paul Scherrer Institute. Measurements were made upon ultracold neutrons stored within a single chamber at the heart of our…
We present the new spectrometer for the neutron electric dipole moment (nEDM) search at the Paul Scherrer Institute (PSI), called n2EDM. The setup is at room temperature in vacuum using ultracold neutrons. n2EDM features a large UCN double…
Magnetic field uniformity is of the utmost importance in experiments to measure the electric dipole moment of the neutron. A general parametrization of the magnetic field in terms of harmonic polynomial modes is proposed, going beyond the…
The TRIUMF Ultracold Advanced Neutron (TUCAN) collaboration has commissioned a large magnetically shielded room to be used for measuring the neutron electric dipole moment (nEDM) to a precision of $10^{-27}~e\mathrm{cm}$. The room is…
Experiments dedicated to the measurement of the electric dipole moment of the neutron require outstanding control of the magnetic field uniformity. The neutron electric dipole moment (nEDM) experiment at the Paul Scherrer Institute uses a…
The quest for a non-zero electric dipole moment (EDM) of simple systems such as the electron, the neutron or atoms / molecules is a pow- erful way to search for physics beyond the standard model (SM) in par- ticular for new sources of CP…
New sources of CP violation beyond the Standard Model of particle physics could be revealed in the laboratory by measuring a non-zero electric dipole moment (EDM) of a spin 1/2 particle such as the neutron. Despite the great sensitivity…
Future experiments seeking to measure the neutron electric dipole moment (nEDM) require stable and homogeneous magnetic fields. Normally these experiments use a coil internal to a passively magnetically shielded volume to generate the…
Ultra-low noise magnetic field is essential for many branches of scientific research. Examplesinclude experiments conducted on ultra-cold atoms, quantum simulations, as well as precisionmeasurements. In ultra-cold atom experiments…
An array of sixteen laser-pumped scalar Cs magnetometers was part of the neutron electric dipole moment (nEDM) experiment taking data at the Paul Scherrer Institute in 2015 and 2016. It was deployed to measure the gradients of the…
We present the result of an experiment to measure the electric dipole moment (EDM) of the neutron at the Paul Scherrer Institute using Ramsey's method of separated oscillating magnetic fields with ultracold neutrons (UCN). Our measurement…