相关论文: Off-resonance artifact correction for magnetic res…
Off-resonance artifacts in magnetic resonance imaging (MRI) are visual distortions that occur when the actual resonant frequencies of spins within the imaging volume differ from the expected frequencies used to encode spatial information.…
Magnetic Resonance Imaging (MRI) suffers from several artifacts, the most common of which are motion artifacts. These artifacts often yield images that are of non-diagnostic quality. To detect such artifacts, images are prospectively…
Increasing the static magnetic field strength into the realm of ultrahigh fields (7 T and higher) is the central trend in modern magnetic resonance (MR) imaging. The use of ultrahigh fields in MR-imaging leads to numerous effects some of…
Magnetic resonance (MR) imaging relies on conventional electronics that is increasingly challenged by the push for stronger magnetic fields and higher channel count. These problems can be avoided by utilizing optical technologies. As a…
The main disadvantage of Magnetic Resonance Imaging (MRI) are its long scan times and, in consequence, its sensitivity to motion. Exploiting the complementary information from multiple receive coils, parallel imaging is able to recover…
Optically detected magnetic resonance (ODMR) provides ultrasensitive means to detect and image a small number of electron and nuclear spins, down to the single spin level with nanoscale resolution. Despite the significant recent progress in…
Magnetic resonance imaging (MRI) is the cornerstone technique for diagnostic medicine, biology, and neuroscience. This imaging method is highly innovative, noninvasive and its impact continues to grow. It can be used for measuring changes…
Magnetic resonance (MR) imaging is commonly used in the clinical setting to non-invasively monitor the body. There exists a large variability in MR imaging due to differences in scanner hardware, software, and protocol design. Ideally, a…
For several years, numerous attempts have been made to reduce noise and artifacts in MRI. Although there have been many successful methods to address these problems, practical implementation for clinical images is still challenging because…
Magnetic resonance imaging (MRI) has greatly advanced neuroscience research and clinical diagnostics. However, imaging data collected across different scanners, acquisition protocols, or imaging sites often exhibit substantial…
The spatial resolution of magnetic resonance imaging (MRI) is fundamentally limited by the width of Lorentzian point spread functions (PSF) associated with the exponential decay rate of transverse magnetization (1/T2*). Here we show a…
Presently, Magnetic Resonance Imaging (MRI) magnets must deliver excellent magnetic field (B0) uniformity to achieve optimum image quality. Long magnets can satisfy the homogeneity requirements but require considerable superconducting…
Image corruption by motion artifacts is an ingrained problem in Magnetic Resonance Imaging (MRI). In this work, we propose a neural network-based regularization term to enhance Autofocusing, a classic optimization-based method to remove…
Motion is one of the main sources for artifacts in magnetic resonance (MR) images. It can have significant consequences on the diagnostic quality of the resultant scans. Previously, supervised adversarial approaches have been suggested for…
Motion represents one of the major challenges in magnetic resonance imaging (MRI). Since the MR signal is acquired in frequency space, any motion of the imaged object leads to complex artefacts in the reconstructed image in addition to…
Recent innovations in Magnetic Resonance Imaging (MRI) hardware and software have reignited interest in low-field ($<1\,\mathrm{T}$) and ultra-low-field MRI ($<0.1\,\mathrm{T}$). These technologies offer advantages such as lower power…
Purpose: Off-resonance artifact correction by deep-learning, to facilitate rapid pediatric body imaging with a scan time efficient 3D cones trajectory. Methods: A residual convolutional neural network to correct off-resonance artifacts…
Neural Radiance Field (NeRF), capable of synthesizing high-quality novel viewpoint images, suffers from issues like artifact occurrence due to its fixed sampling points during rendering. This study proposes a method that optimizes sampling…
Magnetic Resonance Imaging (MRI) has become one of the most important tools to screen humans in medicine, virtually every modern hospital is equipped with an NMR tomograph. The potential of NMR in 3D imaging tasks is by far greater, but…
Magnetic Resonance Imaging (MRI) is highly susceptible to motion artifacts due to the extended acquisition times required for k-space sampling. These artifacts can compromise diagnostic utility, particularly for dynamic imaging. We propose…