相关论文: CMOS Pixel Sensor Response to Low Energy Electrons…
The elastic and inelastic high--energy small--angle electron--positron scattering is considered. All radiative corrections to the cross--section with the relative accuracy $\delta\sigma/ \sigma = 0.1 \% $ are explicitly taken into account.…
Analogue test structures were fabricated using the Tower Partners Semiconductor Co. CMOS 65 nm ISC process. The purpose was to characterise and qualify this process and to optimise the sensor for the next generation of Monolithic Active…
The next generation of MAPS for future tracking detectors will have to meet stringent requirements placed on them. One such detector is the ALICE ITS3 that aims to be very light at 0.07% X/X$_{0}$ per layer and have a low power consumption…
We present the results of an extensive evaluation of strip and pixel AC-LGAD sensors tested with a 120 GeV proton beam, focusing on the influence of design parameters on the sensor temporal and spatial resolutions. Results show that…
The upcoming Mu3e experiment will search for the charged lepton flavour violating decay of a muon at rest into three electrons. The maximal energy of the electrons is 53 MeV, hence a low material budget is a key performance requirement for…
This paper presents the design and results of detailed tests of a CMOS active pixel chip for charged particle detection with in-pixel charge storage for correlated double sampling and readout in rolling shutter mode at frequencies up to 25…
Transition Edge Sensors (TESs) are amongst the most sensitive cryogenic detectors and can be easily optimized for the detection of massive particles or photons ranging from X-rays all the way down to millimetre radiation. Furthermore, TESs…
The use of highly sensitive pixelated direct detectors has dramatically improved the performance of high energy instrumentation such as transmission electron microscopy. Here, we describe a recently developed monolithic active pixel sensor…
This paper reports on the characterisation with Transient Current Technique measurements of the charge collection and depletion depth of a radiation-hard high-voltage CMOS pixel sensor produced at ams AG. Several substrate resistivities…
The determination of the neutrino mass is an open issue in modern particle physics and astrophysics. The direct mass measurement is the only theory-unrelated experimental tool capable to probe such quantity. The HOLMES experiment aims to…
Previous cryogenic electronics studies are most above 4.2K. In this paper we present the cryogenic characterization of a 0.18{\mu}m standard bulk CMOS technology(1.8V and 5V) at sub-kelvin temperature around 270mK. PMOS and NMOS devices…
Designed as a high-sensitivity gamma-ray observatory, the Fermi Large Area Telescope is also an electron detector with a large acceptance exceeding 2 sq-mt sr at 300 GeV. Building on the gamma-ray analysis, we have developed an efficient…
We have fabricated a custom cryogenic Complementary Metal-Oxide-Semiconductor (CMOS) integrated circuit that has a higher measurement bandwidth compared with conventional room temperature electronics. This allowed implementing single shot…
Future space-based X-ray telescope missions are likely to have significantly increased demands on detector read out rates due to increased collection area, and there will be a desire to minimize radiation damage in the interests of…
In order to achieve the challenging requirements on the CLIC vertex detector, a range of technology options have been considered in recent years. One prominent idea is the use of active sensors implemented in a commercial high-voltage CMOS…
We present a detailed characterization of a new generation of athermal-phonon single-charge sensitive Si HVeV detectors, the best of which achieved 612 meV $\pm$ 4 meV baseline resolution. Our sub-eV energy resolution enables precise…
Images of resolved 5.9 keV electron tracks produced from $^{55}$Fe X-ray interactions are presented for the first time using an optical readout time projection chamber (TPC). The corresponding energy spectra are also shown, with the FWHM…
This paper deals with an analytical modeling of heat transfers simulating a new radiation calorimeter operating in a temperature range from -50 {\deg}C to 150 {\deg}C. The aim of this modeling is the evaluation of the feasibility and…
In recent years, complementary metal-oxide-semiconductor (CMOS) sensors have been demonstrated to have significant potential in X-ray astronomy, where long-term reliability is crucial for space X-ray telescopes. This study examines the…
We report on measurements performed on silicon pixel sensor prototypes exposed to a 200 MeV proton beam at the Indiana University Cyclotron Facility. The sensors are of n+/n/p+ type with multi-guard ring structures on the p+-side and p-stop…