相关论文: Characterization of a Single Crystal Diamond Pixel…
At the n\_TOF experiment at CERN a dedicated single-crystal chemical vapor deposition (sCVD) Diamond Mosaic-Detector has been developed for (n,$\alpha$) cross-section measurements. The detector, characterized by an excellent time and energy…
A novel graphene-optimized silicon carbide PIN detector was fabricated. Its electrical properties, charge collection performance and signal rise time were evaluated under non-irradiated conditions and under X-ray irradiation with an energy…
We describe a robust and reliable fluorescence detector for single atoms that is fully integrated into an atom chip. The detector allows spectrally and spatially selective detection of atoms, reaching a single atom detection efficiency of…
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget…
In order to fully exploit the physics potential of the future high energy e+ e- linear collider, a Vertex Tracker providing high resolution track reconstruction is required. Hybrid pixel sensors are an attractive technology due to their…
We have developed a large CdTe pixel detector with dimensions of 23.7 x 13.0 mm and a pixel size of 448 x 448 um^2. The detector is based on recent technologies of an uniform CdTe single crystal, a two-dimensional ASIC, and stud…
This paper presents the results of the characterisation of a pixel sensor manufactured in OKI 0.2 micron SOI technology integrated on a high-resistivity substrate, and featuring several pixel cell layouts for charge collection optimisation.…
In order to evaluate the charge collection efficiency (CCE) profile of single-crystal diamond devices based on a p type/intrinsic/metal configuration, a lateral Ion Beam Induced Charge (IBIC) analysis was performed over their cleaved cross…
The extremely low dark current of silicon carbide (SiC) detectors, even after high-fluence irradiation, was utilized to develop a beam monitoring system for a wide range of particle rates, i.e., from the kHz to the GHz regime. The system is…
In order to achieve the challenging requirements on the CLIC vertex detector, a range of technology options have been considered in recent years. One prominent idea is the use of active sensors implemented in a commercial high-voltage CMOS…
A graphene-optimized silicon carbide PIN detector was fabricated and its radiation tolerance under X-ray irradiation of 160 keV was evaluated. Its electrical properties, charge collection performance and time resolution of beta-particles…
Monolithic Active Pixel Sensors (MAPS) have been developed since the late 1990s employing silicon substrate with a thin epitaxial layer in which deposited charge is collected by disordered diffusion rather than by drift in an electric…
We have developed a non-destructive readout system that uses a floating-gate amplifier on a thick, fully depleted charge coupled device (CCD) to achieve ultra-low readout noise of 0.068 e- rms/pix. This is the first time that discrete…
Further development of quantum emitter based communication and sensing applications intrinsically depends on the availability of robust single-photon detectors. Here, we demonstrate a new generation of superconducting single-photon…
The PICOSEC detection concept consists in a "two-stage" Micromegas detector coupled to a Cherenkov radiator and equipped with a photocathode. A proof of concept has already been tested: a single-photoelectron response of 76 ps has been…
The Large Hadron Collider (LHC) experiments ATLAS and CMS have established hybrid pixel detectors as the instrument of choice for particle tracking and vertexing in high rate and radiation environments, as they operate close to the LHC…
We discuss a new class of Micro Pattern Gas Detectors, the Gas Pixel Detector (GPD), in which a complete integration between the gas amplification structure and the read-out electronics has been reached. An Application-Specific Integrated…
We report on the systematic study of a single-gas-electron-multiplication (GEM) loaded gaseous detector developed for precision measurements of high-energy particle beams and dose-verification measurements. In the present study, a…
We evaluate the performances of a 100 um-thick silicon strip detector (SSD) with a 300 MeV proton beam and a 90Sr beta-ray source. Signals from the SSD have been read out using a VLSI chip. Common-mode noise, signal separation efficiency…
The escalating demand for ultraviolet (UV) sensing in space exploration, environmental monitoring, and agricultural productivity necessitates detectors that are both environmentally and mechanically resilient. Diamond, featuring its high…