中文
相关论文

相关论文: Calibration of Plastic Phoswich Detectors for Char…

200 篇论文

In order to understand the performance of the PARIS (Photon Array for the studies with Radioactive Ion and Stable beams) detector, detailed characterization of two individual phoswich (LaBr$_3$(Ce)-NaI(Tl)) elements has been carried out.…

A large 4$\pi$ array of charged particle detectors has been developed at Variable Energy Cyclotron Centre to facilitate high resolution charged particle reaction and spectroscopy studies by detecting event-by-event the charged reaction…

We have studied neutron response of PARIS phoswich [LaBr$_3$(Ce)-NaI(Tl)] detector which is being developed for measuring the high energy (E$_{\gamma}$ = 5 - 30 MeV) $\gamma$ rays emitted from the decay of highly collective states in atomic…

仪器与探测器 · 物理学 2017-08-23 Balaram Dey , C Ghosh , S. Pal , V. Nanal , R. G. Pillay , K. V. Anoop , M. S. Pose

Plastic scintillators are widely used in high-energy and medical physics, often for measuring the energy of ionizing radiation. Their main disadvantage is their non-linear response to highly ionizing radiation, called ionization quenching.…

仪器与探测器 · 物理学 2021-02-03 Thomas Pöschl , Daniel Greenwald , Martin Jan Losekamm , Stephan Paul

New calibrations of CR39 and Makrofol nuclear track detectors have been obtained using 158 A GeV Pb (82+) and In (49+) ions; a new method for the bulk etch rate determination, using both cone height and base diameter measurements was…

A 0.93 gram $1{\times}1{\times}0.4$ cm$^3$ SuperCDMS silicon HVeV detector operated at 30 mK was illuminated by 1.91 eV photons using a room temperature pulsed laser coupled to the cryostat via fiber optic. The detector's response under a…

The proton analyzing power in carbon has been measured for energies of 82 to 217 MeV and proton scattering angles of 5 to 41 degrees. The measurements were carried out using polarized protons from the elastic scattering H(pol. e, pol. p)…

A new type of gaseous micropattern particle detector based on a closed-cell microcavity plasma panel sensor is reported. The first device was fabricated with 1 x 1 x 2 mm cells. It has shown very clean signals of 0.6 to 2.5 volt amplitude,…

The results of the study of the multiwire porous dielectric detector and microstrip porous dielectric detector filled with porous CsI are presented. Detectors were exposed to $\alpha $-particles with energy of 5.46 MeV and X-rays with…

仪器与探测器 · 物理学 2015-06-26 M. P. Lorikyan

Silicon carbide (SiC) Schottky diodes 21 mum thick with small surfaces and high N-dopant concentration have been used to detect alpha particles and low energy light ions. In particular 12C and 16O beams at incident energies between 5 and 18…

核实验 · 物理学 2009-11-11 M. De Napoli , G. Raciti , E. Rapisarda , C. Sfienti

The response of a CdWO4 crystal scintillator to protons, alpha particles, Li, C, O and Ti ions with energies in the range 1 - 10 MeV was measured. The non-proportionality of CdWO4 for low energy electrons (4 - 110 keV) was studied with the…

A multi-detector array has been constructed for the simultaneous measurement of energy- and angular correlation of electron-positron pairs produced in internal pair conversion (IPC) of nuclear transitions up to 18 MeV. The response…

The linear response of CsI(Tl) crystals to $\gamma$-rays plays a crucial role in their calibration, as any deviation from linearity can introduce systematic errors not negligible in the measurement of $\gamma$ energy spectra, particularly…

仪器与探测器 · 物理学 2025-07-08 Junhuai Xu , Dawei Si , Yuhao Qin , Mengke Xu , Kaijie Chen , Zirui Hao , Gongtao Fan , Hongwei Wang , Yijie Wang , Zhigang Xiao

A novel graphene-optimized silicon carbide PIN detector was fabricated. Its electrical properties, charge collection performance and signal rise time were evaluated under non-irradiated conditions and under X-ray irradiation with an energy…

仪器与探测器 · 物理学 2026-05-07 Yingjie Huang , Congcong Wang , Jingxuan He , Yi Zhan , Zhenyu Jiang , Xiyuan Zhang , Xin Shi

The fine-sampling electromagnetic calorimeter prototype has been experimentally tested using the 1-19 GeV/c tagged beams of negatively charged particles at the U70 accelerator at IHEP, Protvino. The energy resolution measured by electrons…

A prototype Silicon-Tungsten electromagnetic calorimeter (ECAL) for an International Linear Collider (ILC) detector was installed and tested during summer and autumn 2006 at CERN. The detector had 6480 silicon pads of dimension 1x1 cm^2.…

仪器与探测器 · 物理学 2017-07-24 CALICE Collaboration

We present a method to measure the relative spectral response of the Pierre Auger Observatory Fluorescence Detector. The calibration was done at wavelengths of 320, 337, 355, 380 and 405 nm using an end-to-end technique in which the…

天体物理学 · 物理学 2019-08-13 A. C. Rovero , P. Bauleo , J. T. Brack , J. L. Harton , R. Knapik

This paper presents the results of a study of the response of a test CMOS sensor with a radiation tolerant pixel cell design to 80 keV and 100 keV electrons. The point spread function is measured to be (13.0+/- 1.7) microns at 100 keV and…

仪器与探测器 · 物理学 2009-06-25 Marco Battaglia , Devis Contarato , Peter Denes , Dionisio Doering , Velimir Radmilovic

The microhexcavity plasma panel detector is a type of gaseous particle detector consisting of a close-packed array of millimeter-size hexagonal cells. The cells are biased to operate in Geiger mode where each cell functions as an…