相关论文: Characterization of Spurious Charge in SENSEI Skip…
A Resistive Plate Chamber using Diamond-Like Carbon electrodes (DLC-RPC) has been developed as a background tagging detector in the MEG$~$II experiment. The DLC-RPC is planned to be installed in a high-intensity and low-momentum muon beam.…
Recent progress in the development of superconducting nanowire single-photon detectors (SNSPD) has delivered ex-cellent performance, and their increased adoption has had a great impact on a range of applications. One of the key…
Measuring single-electron charge is one of the most fundamental quantum technologies. Charge sensing, which is an ingredient for the measurement of single spins or single photons, has been already developed for semiconductor gate-defined…
Recent experiments searching for sub-GeV/$c^2$ dark matter have observed event excesses close to their respective energy thresholds. Although specific to the individual technologies, the measured excess event rates have been consistently…
We have measured for the first time the charge-changing cross sections ($\sigma_{\text{CC}}$) of $^{12-16}$C on a $^{12}$C target at energies below $100A$ MeV. To analyze these low-energy data, we have developed a finite-range Glauber model…
The XENON100 dark matter experiment uses liquid xenon in a time projection chamber (TPC) to measure xenon nuclear recoils resulting from the scattering of dark matter Weakly Interacting Massive Particles (WIMPs). In this paper, we report…
Spin-based applications of the negatively charged nitrogen-vacancy (NV) center in diamonds require efficient spin readout. One approach is the spin-to-charge conversion (SCC), relying on mapping the spin states onto the neutral (NV$^0$) and…
Charge-coupled devices (CCDs) are a leading technology in direct dark matter searches because of their eV-scale energy threshold and high spatial resolution. The sensitivity of future CCD experiments could be enhanced by distinguishing…
Spherical Proportional Counters (SPCs) are a novel gaseous detector technology employed by the NEWS-G low-mass dark matter search experiment for their high sensitivity to single electrons from ionization. In this paper, we report on the…
The increase in the number of counterfeit and recycled microelectronic chips in recent years has created significant security and safety concerns in various applications. Hence, detecting such counterfeit chips in electronic systems is…
We report on broadband dielectric spectroscopy on the one-dimensional semiconductor (NbSe4)3I. Below the structural phase transition close to 270 K we observe colossal dielectric constants with a frequency and temperature dependence very…
Numerous applications at the photon-starved regime require a free-space coupling singlephoton detector with a large active area, low dark count rate (DCR), and superior time resolutions. Here,we developed a superconducting microstrip…
The purpose of this project is to investigate the use of charge couple devices (CCDs) to detect electrons directly. This can be done in transmission electron microscopy (TEM) for electrons over 100 KeV, but for space plasma instruments,…
Conventional readout of a superconducting nanowire single-photon detector (SNSPD) sets an upper bound on the output voltage to be the product of the bias current and the load impedance, $I_\mathrm{B}\times Z_\mathrm{load}$, where…
We present a concept to improve the spatial resolution of silicon pixel-detectors via the implementation of a sub-pixel cross-coupling, which introduces directional charge sharing between pixels. The charge-collection electrode is segmented…
Using multi-channel time-resolved current measurements (multi TCT), the charge collection of p+n silicon strip sensors for electron-hole pairs produced close to the Si-SiO2 interface by a focussed sub-nanosecond laser with a wavelength of…
Dark matter (DM) detectors employing a Spherical Proportional Counter (SPC) have demonstrated a single-electron detection threshold and are projected to have small background rates. We explore the sensitivity to DM-electron scattering with…
Charge-Coupled Device (CCD) detectors, widely used to obtain digital imaging, can be damaged by high energy radiation. Degraded images appear blurred, because of an effect known as Charge Transfer Inefficiency (CTI), which trails bright…
The STAR Silicon Strip Detector (SSD) completes the three layers of the Silicon Vertex Tracker (SVT) to make an inner tracking system located inside the Time Projection Chamber (TPC). This additional fourth layer provides two dimensional…
Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their high spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived…