相关论文: Reducing CT Metal Artifacts by Learning Latent Spa…

200 篇论文

Metallic implants introduce severe artifacts in CT images, which degrades the image quality. It is an effective method to reduce metal artifacts by replacing the metal affected projection with the forward projection of a prior image. How to…

医学物理 · 物理学 2014-09-05 Yanbo Zhang , Xuanqian Mou

Metal artifacts from high-attenuation implants severely degrade CT image quality, obscuring critical anatomical structures and posing a challenge for standard deep learning methods that require extensive paired training data. We propose a…

计算机视觉与模式识别 · 计算机科学 2026-04-08 Ahmet Rasim Emirdagi , Süleyman Aslan , Mısra Yavuz , Görkay Aydemir , Yunus Bilge Kurt , Nasrin Rahimi , Burak Can Biner , M. Akın Yılmaz

In computed tomography (CT), metal implants increase the inconsistencies between the measured data and the linear attenuation assumption made by analytic CT reconstruction algorithms. The inconsistencies give rise to dark and bright bands…

计算机视觉与模式识别 · 计算机科学 2018-08-07 Sungsoo Ha , Klaus Mueller

During X-ray computed tomography (CT) scanning, metallic implants carrying with patients often lead to adverse artifacts in the captured CT images and then impair the clinical treatment. Against this metal artifact reduction (MAR) task, the…

图像与视频处理 · 电气工程与系统科学 2022-12-27 Hong Wang , Qi Xie , Yuexiang Li , Yawen Huang , Deyu Meng , Yefeng Zheng

Metal Artifacts creates often difficulties for a high quality visual assessment of post-operative imaging in {c}omputed {t}omography (CT). A vast body of methods have been proposed to tackle this issue, but {these} methods were designed for…

计算机视觉与模式识别 · 计算机科学 2021-04-27 Wang Zihao , Vandersteen Clair , Demarcy Thomas , Gnansia Dan , Raffaelli Charles , Guevara Nicolas , Delingette Herve

A conventional approach to computed tomography (CT) or cone beam CT (CBCT) metal artifact reduction is to replace the X-ray projection data within the metal trace with synthesized data. However, existing projection or sinogram completion…

图像与视频处理 · 电气工程与系统科学 2022-03-24 Haofu Liao , Wei-An Lin , Zhimin Huo , Levon Vogelsang , William J. Sehnert , S. Kevin Zhou , Jiebo Luo

The presence of metallic implants often introduces severe metal artifacts in the X-ray CT images, which could adversely influence clinical diagnosis or dose calculation in radiation therapy. In this work, we present a novel…

图像与视频处理 · 电气工程与系统科学 2021-09-29 Lequan Yu , Zhicheng Zhang , Xiaomeng Li , Hongyi Ren , Wei Zhao , Lei Xing

Computed tomography (CT) has been widely used for medical diagnosis, assessment, and therapy planning and guidance. In reality, CT images may be affected adversely in the presence of metallic objects, which could lead to severe metal…

图像与视频处理 · 电气工程与系统科学 2020-09-17 Lequan Yu , Zhicheng Zhang , Xiaomeng Li , Lei Xing

CT images have been used to generate radiation therapy treatment plans for more than two decades. Dual-energy CT (DECT) has shown high accuracy in estimating electronic density or proton stopping-power maps used in treatment planning.…

图像与视频处理 · 电气工程与系统科学 2022-02-02 Tao Ge , Maria Medrano , Rui Liao , Jeffrey F. Williamson , David G. Politte , Bruce R. Whiting , Joseph A. O'Sullivan

Metal artifacts, caused by high-density metallic implants in computed tomography (CT) imaging, severely degrade image quality, complicating diagnosis and treatment planning. While existing deep learning algorithms have achieved notable…

计算机视觉与模式识别 · 计算机科学 2025-08-15 Farid Tasharofi , Fuxin Fan , Melika Qahqaie , Mareike Thies , Andreas Maier

The presence of metal implants within CT imaging causes severe attenuation of the X-ray beam. Due to the incomplete information recorded by CT detectors, artifacts in the form of streaks and dark bands would appear in the resulting CT…

High density implants such as metals often lead to serious artifacts in the reconstructed CT images which hampers the accuracy of image based diagnosis and treatment planning. In this paper, we propose a novel wavelet frame based CT image…

医学物理 · 物理学 2017-11-21 Haimiao Zhang , Bin Dong , Baodong Liu

Metal artifact reduction (MAR) in computed tomography (CT) is a notoriously challenging task because the artifacts are structured and non-local in the image domain. However, they are inherently local in the sinogram domain. Thus, one…

图像与视频处理 · 电气工程与系统科学 2021-03-09 Yuanyuan Lyu , Wei-An Lin , Haofu Liao , Jingjing Lu , S. Kevin Zhou

For extending CT field-of-view to perform non-destructive testing, the Symmetric Multi-Linear trajectory Computed Tomography (SMLCT) has been developed as a successful example of non-standard CT scanning modes. However, inevitable geometric…

计算机视觉与模式识别 · 计算机科学 2024-08-28 Zhisheng Wang , Yanxu Sun , Shangyu Li , Legeng Lin , Shunli Wang , Junning Cui

Purpose: This study presents a variable resolution (VR) sampling and deep learning reconstruction approach for multi-spectral MRI near metal implants, aiming to reduce scan times while maintaining image quality. Background: The rising use…

图像与视频处理 · 电气工程与系统科学 2024-11-01 Azadeh Sharafi , Nikolai J. Mickevicius , Mehran Baboli , Andrew S. Nencka , Kevin M. Koch

Computed tomography (CT) is an imaging modality widely used for medical diagnosis and treatment. CT images are often corrupted by undesirable artifacts when metallic implants are carried by patients, which creates the problem of metal…

图像与视频处理 · 电气工程与系统科学 2019-07-02 Wei-An Lin , Haofu Liao , Cheng Peng , Xiaohang Sun , Jingdan Zhang , Jiebo Luo , Rama Chellappa , Shaohua Kevin Zhou

Computed tomography (CT) metal artifact reduction (MAR) aims to reduce the severe streaking artifacts induced by metallic implants and other high-density objects. Effective MAR generally requires both accurate artifact localization and…

计算机视觉与模式识别 · 计算机科学 2026-05-19 Zilong Li , Chenglong Ma , Yiming Lei , Yuanlin Li , Jing Han , Jiannan Liu , Huidong Xie , Junping Zhang , Yi Zhang , Hongming Shan

Metal artifacts is a major challenge in computed tomography (CT) imaging, significantly degrading image quality and making accurate diagnosis difficult. However, previous methods either require prior knowledge of the location of metal…

图像与视频处理 · 电气工程与系统科学 2023-06-21 Jiandong Su , Ce Wang , Yinsheng Li , Kun Shang , Dong Liang

Computed tomography (CT) images are often severely corrupted by artifacts in the presence of metals. Existing supervised metal artifact reduction (MAR) approaches suffer from performance instability on known data due to their reliance on…

计算机视觉与模式识别 · 计算机科学 2025-12-11 Jie Wen , Chenhe Du , Xiao Wang , Yuyao Zhang

Computed tomography (CT) images are frequently degraded by acquisition artifacts, including noise, blur, streaking, aliasing, and metal artifacts. Yet CT enhancement is still largely evaluated using image quality metrics with limited…