相关论文: Algorithm To Calculate Pulse from PPG Signal After…

200 篇论文

In this paper, we propose a system that enables photoplethysmogram (PPG)-based authentication by using a smartphone camera. PPG signals are obtained by recording a video from the camera as users are resting their finger on top of the camera…

计算机视觉与模式识别 · 计算机科学 2020-11-06 Giulio Lovisotto , Henry Turner , Simon Eberz , Ivan Martinovic

In recent years, research about monitoring vital signs by smartphones grows significantly. There are some special sensors like Electrocardiogram (ECG) and Photoplethysmographic (PPG) to detect heart rate (HR) and respiration rate (RR).…

图像与视频处理 · 电气工程与系统科学 2021-06-08 Jafar Pourbemany , Almabrok Essa , Ye Zhu

Smartphone-based heart rate (HR) monitoring apps using finger-over-camera photoplethysmography (PPG) face significant challenges in performance evaluation and device compatibility due to device variability and fragmentation. Manual testing…

计算机视觉与模式识别 · 计算机科学 2025-07-01 Ming-Zher Poh , Jonathan Wang , Jonathan Hsu , Lawrence Cai , Eric Teasley , James A. Taylor , Jameson K. Rogers , Anupam Pathak , Shwetak Patel

Background: A smartphone is a promising tool for daily cardiovascular measurement and mental stress monitoring. A smartphone camera-based PhotoPlethysmoGraphy (PPG) and a low-cost thermal camera can be used to create cheap, convenient and…

医学物理 · 物理学 2019-01-03 Youngjun Cho , Simon J. Julier , Nadia Bianchi-Berthouze

Camera-based monitoring of vital signs, also known as imaging photoplethysmography (iPPG), has seen applications in driver-monitoring, perfusion assessment in surgical settings, affective computing, and more. iPPG involves sensing the…

计算机视觉与模式识别 · 计算机科学 2025-03-24 Vineet R Shenoy , Suhas Lohit , Hassan Mansour , Rama Chellappa , Tim K. Marks

This work proposes a smartphone video-based approach for the estimation of blood glucose in a non-invasive way. Videos using smartphone camera are collected from the tip of the subjects finger and the frames are subsequently converted into…

信号处理 · 电气工程与系统科学 2019-12-02 Tauseef Tasin Chowdhury , Tahmin Mishma , Md. Saeem Osman , Tanzilur Rahman

The electrocardiogram (ECG) signal is one of the most vital signals that can be used to investigate the performance of heart. Based on the ECG graph, we can identify different disorders and diseases. Therefore, monitoring this signal is of…

信号处理 · 电气工程与系统科学 2023-02-22 Soheil Khooyooz , Mohammad Ali Ahmadi-Pajouh , Kamyab Azizi

Cardiac abnormalities affecting heart rate and rhythm are commonly observed in both healthy and acutely unwell people. Although many of these are benign, they can sometimes indicate a serious health risk. ECG monitors are typically used to…

信号处理 · 电气工程与系统科学 2018-07-12 Stewart Whiting , Samuel Moreland , Jason Costello , Glen Colopy , Christopher McCann

Goal: A new method for heart rate monitoring using photoplethysmography (PPG) during physical activities is proposed. Methods: It jointly estimates spectra of PPG signals and simultaneous acceleration signals, utilizing the multiple…

其他计算机科学 · 计算机科学 2015-07-22 Zhilin Zhang

Smart watches and other wearable devices are equipped with photoplethysmography (PPG) sensors for monitoring heart rate and other aspects of cardiovascular health. However, PPG signals collected from such devices are susceptible to…

信号处理 · 电气工程与系统科学 2023-07-12 Pranay Jain , Cheng Ding , Cynthia Rudin , Xiao Hu

Objective: to establish an algorithmic framework and a benchmark dataset for comparing methods of pulse rate estimation using imaging photoplethysmography (iPPG). Approach: first we reveal essential steps of pulse rate estimation from…

图像与视频处理 · 电气工程与系统科学 2018-05-01 Anton M. Unakafov

Biometric authentication prospered because of its convenient use and security. Early generations of biometric mechanisms suffer from spoofing attacks. Recently, unobservable physiological signals (e.g., Electroencephalogram,…

密码学与安全 · 计算机科学 2024-01-29 Lin Li , Chao Chen , Lei Pan , Leo Yu Zhang , Zhifeng Wang , Jun Zhang , Yang Xiang

The use of observed wearable sensor data (e.g., photoplethysmograms [PPG]) to infer health measures (e.g., glucose level or blood pressure) is a very active area of research. Such technology can have a significant impact on health…

信号处理 · 电气工程与系统科学 2023-05-01 Suril Mehta , Nipun Kwatra , Mohit Jain , Daniel McDuff

In this paper, we propose an algorithm denoted as HeartBEAT that tracks heart rate from wrist-type photoplethysmography (PPG) signals and simultaneously recorded three-axis acceleration data. HeartBEAT contains three major parts: spectrum…

信号处理 · 电气工程与系统科学 2018-11-14 Huijie Pan , Dogancan Temel , Ghassan AlRegib

Despite the population of the noninvasive, economic, comfortable, and easy-to-install photoplethysmography (PPG), it is still lacking a mathematically rigorous and stable algorithm which is able to simultaneously extract from a…

神经元与认知 · 定量生物学 2017-09-05 Antonio Cicone , Hau-Tieng Wu

Utilizing mobile phone cameras for continuous blood pressure (BP) monitoring presents a cost-effective and accessible approach, yet it is challenged by limitations in accuracy and interpretability. This study introduces four innovative…

信号处理 · 电气工程与系统科学 2024-07-25 Ivan Liu , Fangyuan Liu , Qi Zhong , Shiguang Ni

Smartwatches have become popular for monitoring physiological parameters outside clinical settings. Using reflective photoplethysmography (PPG) sensors, such watches can non-invasively estimate heart rate (HR) in everyday environments and…

信号处理 · 电气工程与系统科学 2024-12-24 Manuel Meier , Christian Holz

This paper considers the problem of casual heart rate tracking during intensive physical exercise using simultaneous 2 channel photoplethysmographic (PPG) and 3 dimensional (3D) acceleration signals recorded from wrist. This is a…

信息论 · 计算机科学 2016-09-13 Mahdi Boloursaz Mashhadi , Ehsan Asadi , Mohsen Eskandari , Shahrzad Kiani , Farrokh Marvasti

Photoplethysmography (PPG) is one of the most widely captured biosignals for clinical prediction tasks, yet PPG-based algorithms are typically trained on small-scale datasets of uncertain quality, which hinders meaningful algorithm…

机器学习 · 计算机科学 2026-03-24 Mohammad Moulaeifard , Philip J. Aston , Peter H. Charlton , Nils Strodthoff

Electrocardiogram (ECG) is the electrical measurement of cardiac activity, whereas Photoplethysmogram (PPG) is the optical measurement of volumetric changes in blood circulation. While both signals are used for heart rate monitoring, from a…

机器学习 · 计算机科学 2020-12-16 Pritam Sarkar , Ali Etemad