中文
相关论文

相关论文: Inexpensive and Portable System for Dexterous High…

200 篇论文

Electromyography (EMG) is a measure of muscular electrical activity and is used in many clinical/biomedical disciplines and modern human computer interaction. Myo-electric prosthetics analyze and classify the electrical signals recorded…

机器人学 · 计算机科学 2024-11-26 Mosab Diab , Ashraf Mohammed , Yinlai Jiang

Affordable upper-limb prostheses often lack intuitive control systems, limiting functionality and accessibility for amputees in low-resource settings. This project presents a low-cost, dual-mode neuro-muscular control system integrating…

机器学习 · 计算机科学 2025-12-22 Pranesh Sathish Kumar

Many amputees throughout the world are left with limited options to personally own a prosthetic arm due to the expensive cost, mechanical system complexity, and lack of availability. The three main control methods of prosthetic hands are:…

人工智能 · 计算机科学 2021-03-04 Alishba Imran , William Escobar , Freidoon Barez

The creation of unique control methods for a hand prosthesis is still a problem that has to be addressed. The best choice of a human-machine interface (HMI) that should be used to enable natural control is still a challenge. Surface…

Currently, individuals with arm mobility impairments (referred to as "patients") face limited technological solutions due to two key challenges: (1) non-invasive prosthetic devices are often prohibitively expensive and costly to maintain,…

人工智能 · 计算机科学 2025-01-28 Maha Nawaz , Abdul Basit , Muhammad Shafique

Surface electromyography (sEMG) is a popular bio-signal used for controlling prostheses and finger gesture recognition mechanisms. Myoelectric prostheses are costly, and most commercially available sEMG acquisition systems are not suitable…

Consumer-grade biosensors offer a cost-effective alternative to medical-grade electromyography (EMG) systems, reducing hardware costs from thousands of dollars to approximately $13. However, these low-cost sensors introduce significant…

人机交互 · 计算机科学 2026-01-13 Carl Vincent Ladres Kho

The dexterity of conventional myoelectric prostheses is limited in part by the small datasets used to train the control algorithms. Variations in surface electrode positioning make it difficult to collect consistent data and to estimate…

机器人学 · 计算机科学 2020-03-03 Jacob A. George , Anna Neibling , Michael D. Paskett , Gregory A. Clark

Sonomyography (SMG) is a novel human-machine interface that controls upper-limb prostheses by monitoring forearm muscle activity using ultrasonic imaging. SMG has been investigated for controlling upper-limb prostheses during the last two…

系统与控制 · 电气工程与系统科学 2024-07-30 Vaheh Nazari , Yong-Ping Zheng

Noninvasive human-machine interfaces such as surface electromyography (sEMG) have long been employed for controlling robotic prostheses. However, classical controllers are limited to few degrees of freedom (DoF). More recently, machine…

Prosthetic hands can be used to support upper-body amputees. Myoelectric prosthesis, one of the externally-powered active prosthesis categories, requires proper processing units in addition to recording electrodes and instrumentation…

Electromyography (EMG) signal analysis is a popular method for controlling prosthetic and gesture control equipment. For portable systems, such as prosthetic limbs, real-time low-power operation on embedded processors is critical, but to…

信号处理 · 电气工程与系统科学 2019-05-10 Sumit Raurale , John McAllister , Jesus Martinez del Rincon

Brain Computer Interfaces (BCI) provide the opportunity to control external devices using the brain ElectroEncephaloGram (EEG) signals. In this paper we propose two software framework in order to control a 5 degree of freedom robotic and…

人机交互 · 计算机科学 2016-03-10 Daniel Elstob , Emanuele Lindo Secco

One of the most elusive goals in myographic prosthesis control is the ability to reliably decode continuous positions simultaneously across multiple degrees-of-freedom. Goal: To demonstrate dexterous, natural, biomimetic finger and wrist…

Natural muscles provide mobility in response to nerve impulses. Electromyography (EMG) measures the electrical activity of muscles in response to a nerve's stimulation. In the past few decades, EMG signals have been used extensively in the…

信号处理 · 电气工程与系统科学 2020-01-15 Mohsen Jafarzadeh , Daniel Curtiss Hussey , Yonas Tadesse

Electrocardiogram (EMG) signals play a significant role in decoding muscle contraction information for robotic hand prosthesis controllers. Widely applied decoders require large amount of EMG signals sensors, resulting in complicated…

最优化与控制 · 数学 2022-11-30 Jin Ren , Guohui Song , Lucia Tabacu , Yuesheng Xu

Limb loss affects millions globally, impairing physical function and reducing quality of life. Most traditional surface electromyographic (sEMG) and semi-autonomous methods require users to generate myoelectric signals for each control,…

机器人学 · 计算机科学 2025-06-11 Kaijie Shi , Wanglong Lu , Hanli Zhao , Vinicius Prado da Fonseca , Ting Zou , Xianta Jiang

The electromyography (EMG) signal is the electrical manifestation of a neuromuscular activation that provides access to physiological processes which cause the muscle to generate force and produce movement. Non invasive prostheses use such…

机器学习 · 计算机科学 2015-11-20 Mara Graziani

Background: Multi-articulate prostheses are capable of performing dexterous hand movements. However, clinically available control strategies fail to provide users with intuitive, independent and proportional control over multiple degrees of…

神经元与认知 · 定量生物学 2019-10-11 Jacob A. George , Tyler S. Davis , Mark R. Brinton , Gregory A. Clark

Building robotic prostheses requires a sensor-based interface designed to provide the robotic hand with the control required to perform hand gestures. Traditional Electromyography (EMG) based prosthetics and emerging alternatives often face…

机器人学 · 计算机科学 2025-07-15 Dean Zadok , Oren Salzman , Alon Wolf , Alex M. Bronstein
‹ 上一页 1 2 3 10 下一页 ›