相关论文: Low-signal limit of X-ray single particle imaging
Single molecule X-ray scattering experiments using free electron lasers hold the potential to resolve both single structures and structural ensembles of biomolecules. However, molecular electron density determination has so far not been…
Single-particle imaging experiments of biomolecules at x-ray free-electron lasers (XFELs) require processing of hundreds of thousands (or more) of images that contain very few x-rays. Each low-flux image of the diffraction pattern is…
Schemes for X-ray imaging single protein molecules using new x-ray sources, like x-ray free electron lasers (XFELs), require processing many frames of data that are obtained by taking temporally short snapshots of identical molecules, each…
The number of photons available by coherent X-ray scattering from a single biomolecule is considerably less because of the extremely small elastic-scattering cross-section and low damage threshold. Even with a high X-ray flux of 3 x 10to 12…
The advent of X-ray Free Electron Lasers promises the possibility to determine the structure of individual particles such as microcrystallites, viruses and biomolecules from single-shot diffraction snapshots obtained before the particle is…
X-ray Free Electron Lasers (XFEL) are revolutionary photons sources, whose ultrashort, brilliant pulses are expected to allow single molecule diffraction experiments providing structural information on the atomic length scale. This ultimate…
The routine atomic-resolution structure determination of single particles is expected to have profound implications for probing the structure-function relationship in systems ranging from energy materials to biological molecules.…
Detecting the photons emitted from single quantum objects is highly desired to diagnose nano-scale devices. It has been, however, believed very difficult to sense single atoms in optical spectroscopy due to the inferior detection…
The emergence of high repetition-rate X-ray free-electron lasers (XFELs) powered by superconducting accelerator technology enables the measurement of significantly more experimental data per day than was previously possible. The European…
Single-pixel imaging, originally developed in light optics, facilitates fast three-dimensional sample reconstruction, as well as probing with light wavelengths undetectable by conventional multi-pixel detectors. However, the spatial…
Single molecule X-ray scattering experiments with free electron lasers have opened a new route to the structure determination of biomolecules. Because typically only very few photons per scattering image are recorded and thus the…
The Single Particles, Clusters and Biomolecules (SPB) instrument at the European XFEL is located behind the SASE1 undulator, and aims to support imaging and structure determination of biological specimen between about 0.1 micrometer and 1…
X-ray is a ubiquitous imaging modality in clinical diagnostics and industrial inspections, thanks to its high penetration power. Conventional x-ray imaging system, equipped with energy-integrating detectors, collects approximately 1000 to…
Single biomolecular imaging using XFEL radiation is an emerging method for protein structure determination using the "diffraction before destruction" method at near atomic resolution. Crucial parameters for such bio-imaging experiments are…
X-ray free-electron lasers (XFELs) are the only sources currently able to produce bright few-fs pulses with tunable photon energies from 100 eV to more than 10 keV. Due to the stochastic SASE operating principles and other technical issues…
X-ray emission spectroscopy is a well-established technique used to study continuum lowering in dense plasmas. It relies on accurate atomic physics models to robustly reproduce high-resolution emission spectra, and depends on our ability to…
Single particle diffraction imaging experiments at free-electron lasers (FEL) have a great potential for structure determination of reproducible biological specimens that can not be crystallized. One of the challenges in processing the data…
The lateral resolution of an X-ray photoelectron spectroscopy instrument, which is equipped with a focused X-ray beam, is limited by the nominal X-ray beam diameter and the long tail intensity distri-bution of the X-ray beam. The long tail…
Feynman once asked physicists to build better electron microscopes to be able to watch biology at work. While electron microscopes can now provide atomic resolution, electron beam induced specimen damage precludes high resolution imaging of…
An improved analysis for single particle imaging (SPI) experiments, using the limited data, is presented here. Results are based on a study of bacteriophage PR772 performed at the AMO instrument at the Linac Coherent Light Source (LCLS) as…