相关论文: Metal Artifact Reduction in Cone-Beam X-Ray CT via…

200 篇论文

The presence of metallic implants often introduces severe metal artifacts in the X-ray CT images, which could adversely influence clinical diagnosis or dose calculation in radiation therapy. In this work, we present a novel…

图像与视频处理 · 电气工程与系统科学 2021-09-29 Lequan Yu , Zhicheng Zhang , Xiaomeng Li , Hongyi Ren , Wei Zhao , Lei Xing

During X-ray computed tomography (CT) scanning, metallic implants carrying with patients often lead to adverse artifacts in the captured CT images and then impair the clinical treatment. Against this metal artifact reduction (MAR) task, the…

图像与视频处理 · 电气工程与系统科学 2022-12-27 Hong Wang , Qi Xie , Yuexiang Li , Yawen Huang , Deyu Meng , Yefeng Zheng

Metal artifact reduction (MAR) in computed tomography (CT) is a notoriously challenging task because the artifacts are structured and non-local in the image domain. However, they are inherently local in the sinogram domain. Thus, one…

图像与视频处理 · 电气工程与系统科学 2021-03-09 Yuanyuan Lyu , Wei-An Lin , Haofu Liao , Jingjing Lu , S. Kevin Zhou

Metallic implants introduce severe artifacts in CT images, which degrades the image quality. It is an effective method to reduce metal artifacts by replacing the metal affected projection with the forward projection of a prior image. How to…

医学物理 · 物理学 2014-09-05 Yanbo Zhang , Xuanqian Mou

The presence of metal implants within CT imaging causes severe attenuation of the X-ray beam. Due to the incomplete information recorded by CT detectors, artifacts in the form of streaks and dark bands would appear in the resulting CT…

In the presence of metal implants, metal artifacts are introduced to x-ray CT images. Although a large number of metal artifact reduction (MAR) methods have been proposed in the past decades, MAR is still one of the major problems in…

医学物理 · 物理学 2018-04-23 Yanbo Zhang , Hengyong Yu

Since the invention of modern CT systems, metal artifacts have been a persistent problem. Due to increased scattering, amplified noise, and insufficient data collection, it is more difficult to suppress metal artifacts in cone-beam CT,…

医学物理 · 物理学 2023-10-27 Tianling Lyu , Zhan Wu , Gege Ma , Chen Jiang , Xinyun Zhong , Yan Xi , Yang Chen , Wentao Zhu

Computed tomography (CT) has been widely used for medical diagnosis, assessment, and therapy planning and guidance. In reality, CT images may be affected adversely in the presence of metallic objects, which could lead to severe metal…

图像与视频处理 · 电气工程与系统科学 2020-09-17 Lequan Yu , Zhicheng Zhang , Xiaomeng Li , Lei Xing

Metal artifact correction is a challenging problem in cone beam computed tomography (CBCT) scanning. Metal implants inserted into the anatomy cause severe artifacts in reconstructed images. Widely used inpainting-based metal artifact…

图像与视频处理 · 电气工程与系统科学 2023-10-10 Harshit Agrawal , Ari Hietanen , Simo Särkkä

Computed tomography (CT) is an imaging modality widely used for medical diagnosis and treatment. CT images are often corrupted by undesirable artifacts when metallic implants are carried by patients, which creates the problem of metal…

图像与视频处理 · 电气工程与系统科学 2019-07-02 Wei-An Lin , Haofu Liao , Cheng Peng , Xiaohang Sun , Jingdan Zhang , Jiebo Luo , Rama Chellappa , Shaohua Kevin Zhou

Metal implants can heavily attenuate X-rays in computed tomography (CT) scans, leading to severe artifacts in reconstructed images, which significantly jeopardize image quality and negatively impact subsequent diagnoses and treatment…

医学物理 · 物理学 2021-08-11 Tao Wang , Wenjun Xia , Yongqiang Huang , Huaiqiang Sun , Yan Liu , Hu Chen , Jiliu Zhou , Yi Zhang

An X-ray computed tomography (CT), metal artifact reduction (MAR) remains a major challenge because metallic implants violate standard CT forward-model assumptions, producing severe streaking and shadowing artifacts that degrade diagnostic…

图像与视频处理 · 电气工程与系统科学 2026-03-17 Hyoung Suk Park , Kiwan Jeon

CT images have been used to generate radiation therapy treatment plans for more than two decades. Dual-energy CT (DECT) has shown high accuracy in estimating electronic density or proton stopping-power maps used in treatment planning.…

图像与视频处理 · 电气工程与系统科学 2022-02-02 Tao Ge , Maria Medrano , Rui Liao , Jeffrey F. Williamson , David G. Politte , Bruce R. Whiting , Joseph A. O'Sullivan

This study introduces a novel reconstruction method for dental cone-beam computed tomography (CBCT), focusing on effectively reducing metal-induced artifacts commonly encountered in the presence of prevalent metallic implants. Despite…

计算机视觉与模式识别 · 计算机科学 2023-07-28 Hyoung Suk Park , Kiwan Jeon , Jin Keun Seo

Metal artefact reduction (MAR) techniques aim at removing metal-induced noise from clinical images. In Computed Tomography (CT), supervised deep learning approaches have been shown effective but limited in generalisability, as they mostly…

计算机视觉与模式识别 · 计算机科学 2020-04-21 Marta B. M. Ranzini , Irme Groothuis , Kerstin Kläser , M. Jorge Cardoso , Johann Henckel , Sébastien Ourselin , Alister Hart , Marc Modat

In computed tomography (CT), the presence of metallic implants in patients often leads to disruptive artifacts in the reconstructed images, hindering accurate diagnosis. Recently, a large amount of supervised deep learning-based approaches…

图像与视频处理 · 电气工程与系统科学 2024-06-21 Xinquan Yang , Guanqun Zhou , Wei Sun , Youjian Zhang , Zhongya Wang , Jiahui He , Zhicheng Zhang

Computed tomography (CT) images are often severely corrupted by artifacts in the presence of metals. Existing supervised metal artifact reduction (MAR) approaches suffer from performance instability on known data due to their reliance on…

计算机视觉与模式识别 · 计算机科学 2025-12-11 Jie Wen , Chenhe Du , Xiao Wang , Yuyao Zhang

Filtered back projection (FBP) is the most widely used method for image reconstruction in X-ray computed tomography (CT) scanners. The presence of hyper-dense materials in a scene, such as metals, can strongly attenuate X-rays, producing…

计算机视觉与模式识别 · 计算机科学 2019-08-02 Muhammad Usman Ghani , W. Clem Karl

A conventional approach to computed tomography (CT) or cone beam CT (CBCT) metal artifact reduction is to replace the X-ray projection data within the metal trace with synthesized data. However, existing projection or sinogram completion…

图像与视频处理 · 电气工程与系统科学 2022-03-24 Haofu Liao , Wei-An Lin , Zhimin Huo , Levon Vogelsang , William J. Sehnert , S. Kevin Zhou , Jiebo Luo

Computed tomography (CT) images containing metallic objects commonly show severe streaking and shadow artifacts. Metal artifacts are caused by nonlinear beam-hardening effects combined with other factors such as scatter and Poisson noise.…

医学物理 · 物理学 2017-08-02 Hyung Suk Park , Sung Min Lee , Hwa Pyung Kim , Jin Keun Seo