中文
相关论文

相关论文: Intrinsic backgrounds from Rn and Kr in the XENON1…

200 篇论文

The NEXT-100 detector at the LSC aims at the first competitive search for the \bbnonu decay using a high-pressure \Xe{136} electroluminescent time projection chamber. The first low-background run of NEXT-100 at 3.95 bar has been devoted to…

高能物理 - 实验 · 物理学 2026-04-23 NEXT Collaboration , C. Cortes-Parra , P. Novella , G. Martínez-Lema , H. Almazán , V. Álvarez , L. Arazi , I. J. Arnquist , F. Auria-Luna , S. Ayet , Y. Ayyad , C. D. R. Azevedo , F. Ballester , J. E. Barcelon , M. del Barrio-Torregrosa , J. M. Benlloch-Rodríguez , F. I. G. M. Borges , A. Brodoline , N. Byrnes , A. Castillo , E. Church , M. Cid , X. Cid , C. A. N. Conde , F. P. Cossío , R. Coupe , E. Dey , P. Dietz , C. Echeverria , M. Elorza , R. Esteve , R. Felkai , L. M. P. Fernandes , P. Ferrario , P. Ferrero Mancheño , F. W. Foss , Z. Freixa , J. García-Barrena , J. J. Gómez-Cadenas , J. W. R. Grocott , R. Guenette , J. Hauptman , C. A. O. Henriques , J. A. Hernando Morata , P. Herrero-Gómez , V. Herrero , C. Hervés Carrete , Y. Ifergan , A. F. B. Isabel , B. J. P. Jones , F. Kellerer , L. Larizgoitia , A. Larumbe , P. Lebrun , F. Lopez , N. López-March , R. Madigan , R. D. P. Mano , A. Marauri , A. P. Marques , J. Martín-Albo , A. Martínez , M. Martínez-Vara , R. L. Miller , K. Mistry , J. Molina-Canteras , F. Monrabal , C. M. B. Monteiro , F. J. Mora , K. E. Navarro , D. R. Nygren , E. Oblak , I. Osborne , J. Palacio , B. Palmeiro , A. Para , I. Parmaksiz , A. Pazos , J. Pelegrin , M. Pérez Maneiro , M. Querol , J. Renner , I. Rivilla , C. Rogero , L. Rogers , B. Romeo , C. Romo-Luque , E. Ruiz-Chóliz , P. Saharia , F. P. Santos , J. M. F. dos Santos , M. Seemann , I. Shomroni , A. L. M. Silva , P. A. O. C. Silva , A. Simón , S. R. Soleti , M. Sorel , J. Soto-Oton , J. M. R. Teixeira , S. Teruel-Pardo , J. F. Toledo , C. Tonnelé , S. Torelli , J. Torrent , A. Trettin , P. R. G. Valle , M. Vanga , P. Vázquez Cabaleiro , J. F. C. A. Veloso , J. D. Villamil , L. M. Villar Padruno , J. Waiton , A. Yubero-Navarro

We discuss an in-situ evaluation of the $^{85}$Kr, $^{222}$Rn, and $^{220}$Rn background in PandaX-I, a 120-kg liquid xenon dark matter direct detection experiment. Combining with a simulation, their contributions to the low energy…

天体物理仪器与方法 · 物理学 2017-03-08 Shaoli Li , Xun Chen , Xiangyi Cui , Changbo Fu , Xiangdong Ji , Qing Lin , Jianglai Liu , Xiang Liu , Andi Tan , Xuming Wang , Mengjiao Xiao , Pengwei Xie

The radioactive daughters isotope of 222Rn are one of the highest risk contaminants in liquid xenon detectors aiming for a small signal rate. The noble gas is permanently emanated from the detector surfaces and mixed with the xenon target.…

仪器与探测器 · 物理学 2018-03-14 Natascha Rupp

The selection of low-radioactive construction materials is of the utmost importance for rare-event searches and thus critical to the XENONnT experiment. Results of an extensive radioassay program are reported, in which material samples have…

仪器与探测器 · 物理学 2023-01-27 E. Aprile , K. Abe , F. Agostini , S. Ahmed Maouloud , M. Alfonsi , L. Althueser , E. Angelino , J. R. Angevaare , V. C. Antochi , D. Antón Martin , F. Arneodo , L. Baudis , A. L. Baxter , L. Bellagamba , R. Biondi , A. Bismark , A. Brown , S. Bruenner , G. Bruno , R. Budnik , C. Capelli , J. M. R. Cardoso , D. Cichon , B. Cimmino , M. Clark , A. P. Colijn , J. Conrad , J. J. Cuenca-García , J. P. Cussonneau , V. D'Andrea , M. P. Decowski , P. Di Gangi , S. Di Pede , A. Di Giovanni , R. Di Stefano , S. Diglio , A. Elykov , S. Farrell , A. D. Ferella , H. Fischer , W. Fulgione , P. Gaemers , R. Gaior , M. Galloway , F. Gao , R. Glade-Beucke , L. Grandi , J. Grigat , A. Higuera , C. Hils , K. Hiraide , L. Hoetzsch , J. Howlett , M. Iacovacci , Y. Itow , J. Jakob , F. Joerg , N. Kato , P. Kavrigin , S. Kazama , M. Kobayashi , G. Koltman , A. Kopec , H. Landsman , R. F. Lang , L. Levinson , I. Li , S. Liang , S. Lindemann , M. Lindner , K. Liu , F. Lombardi , J. Long , J. A. M. Lopes , Y. Ma , C. Macolino , J. Mahlstedt , A. Mancuso , L. Manenti , A. Manfredini , F. Marignetti , T. Marrodán Undagoitia , K. Martens , J. Masbou , D. Masson , E. Masson , S. Mastroianni , M. Messina , K. Miuchi , K. Mizukoshi , A. Molinario , S. Moriyama , K. Morå , Y. Mosbacher , M. Murra , K. Ni , U. Oberlack , J. Palacio , R. Peres , J. Pienaar , M. Pierre , V. Pizzella , G. Plante , J. Qi , J. Qin , D. Ramírez García , S. Reichard , A. Rocchetti , N. Rupp , L. Sanchez , J. M. F. dos Santos , G. Sartorelli , J. Schreiner , D. Schulte , H. Schulze Eißing , M. Schumann , L. Scotto Lavina , M. Selvi , F. Semeria , P. Shagin , E. Shockley , M. Silva , H. Simgen , A. Takeda , P. -L. Tan , A. Terliuk , C. Therreau , D. Thers , F. Toschi , G. Trinchero , C. Tunnell , F. Tönnies , K. Valerius , G. Volta , Y. Wei , C. Weinheimer , M. Weiss , D. Wenz , J. Westermann , C. Wittweg , T. Wolf , Z. Xu , M. Yamashita , L. Yang , J. Ye , L. Yuan , G. Zavattini , Y. Zhang , M. Zhong , T. Zhu , J. P. Zopounidis , M. Laubenstein , S. Nisi

The LZ dark matter detector, like many other rare-event searches, will suffer from backgrounds due to the radioactive decay of radon daughters. In order to achieve its science goals, the concentration of radon within the xenon should not…

仪器与探测器 · 物理学 2018-01-17 E. H. Miller , J. Busenitz , T. K. Edberg , C. Ghag , C. Hall , R. Leonard , K. Lesko , X. Liu , Yue Meng , A. Piepke , R. W. Schnee

The XENONnT experiment has achieved an exceptionally low $^\text{222}$Rn activity concentration within its inner 5.9$\,$tonne liquid xenon detector of (0.90$\,\pm\,$0.01$\,$stat.$\,\pm\,$0.07 sys.)$\,\mu$Bq/kg, equivalent to about 430…

仪器与探测器 · 物理学 2025-04-28 E. Aprile , J. Aalbers , K. Abe , S. Ahmed Maouloud , L. Althueser , B. Andrieu , E. Angelino , D. Antón Martin , F. Arneodo , L. Baudis , M. Bazyk , L. Bellagamba , R. Biondi , A. Bismark , K. Boese , A. Brown , G. Bruno , R. Budnik , C. Cai , C. Capelli , J. M. R. Cardoso , A. P. Cimental Chávez , A. P. Colijn , J. Conrad , J. J. Cuenca-García , V. D'Andrea , L. C. Daniel Garcia , M. P. Decowski , A. Deisting , C. Di Donato , P. Di Gangi , S. Diglio , K. Eitel , S. el Morabit , A. Elykov , A. D. Ferella , C. Ferrari , H. Fischer , T. Flehmke , M. Flierman , W. Fulgione , C. Fuselli , P. Gaemers , R. Gaior , M. Galloway , F. Gao , S. Ghosh , R. Giacomobono , R. Glade-Beucke , L. Grandi , J. Grigat , H. Guan , M. Guida , P. Gyorgy , R. Hammann , A. Higuera , C. Hils , L. Hoetzsch , N. F. Hood , M. Iacovacci , Y. Itow , J. Jakob , F. Joerg , Y. Kaminaga , M. Kara , P. Kavrigin , S. Kazama , P. Kharbanda , M. Kobayashi , D. Koke , A. Kopec , H. Landsman , R. F. Lang , L. Levinson , I. Li , S. Li , S. Liang , Z. Liang , Y. -T. Lin , S. Lindemann , M. Lindner , K. Liu , M. Liu , J. Loizeau , F. Lombardi , J. Long , J. A. M. Lopes , T. Luce , Y. Ma , C. Macolino , J. Mahlstedt , A. Mancuso , L. Manenti , F. Marignetti , T. Marrodán Undagoitia , K. Martens , J. Masbou , E. Masson , S. Mastroianni , A. Melchiorre , J. Merz , M. Messina , A. Michael , K. Miuchi , A. Molinario , S. Moriyama , K. Morå , Y. Mosbacher , M. Murra , J. Müller , K. Ni , U. Oberlack , B. Paetsch , Y. Pan , Q. Pellegrini , R. Peres , C. Peters , J. Pienaar , M. Pierre , G. Plante , T. R. Pollmann , L. Principe , J. Qi , J. Qin , D. Ramírez García , M. Rajado , R. Singh , L. Sanchez , J. M. F. dos Santos , I. Sarnoff , G. Sartorelli , J. Schreiner , D. Schulte , P. Schulte , H. Schulze Eißing , M. Schumann , L. Scotto Lavina , M. Selvi , F. Semeria , P. Shagin , S. Shi , J. Shi , M. Silva , H. Simgen , C. Szyszka , A. Takeda , Y. Takeuchi , P. -L. Tan , D. Thers , F. Toschi , G. Trinchero , C. D. Tunnell , F. Tönnies , K. Valerius , S. Vecchi , S. Vetter , F. I. Villazon Solar , G. Volta , C. Weinheimer , M. Weiss , D. Wenz , C. Wittweg , V. H. S. Wu , Y. Xing , D. Xu , Z. Xu , M. Yamashita , L. Yang , J. Ye , L. Yuan , G. Zavattini , M. Zhong

The measurement of the internal $^{222}$Rn activity in the NEXT-White detector during the so-called Run-II period with $^{136}$Xe-depleted xenon is discussed in detail, together with its implications for double beta decay searches in NEXT.…

A Rn-220 source is deployed on the XENON100 dark matter detector in order to address the challenges in calibration of tonne-scale liquid noble element detectors. We show that the Pb-212 beta emission can be used for low-energy electronic…

仪器与探测器 · 物理学 2017-04-27 The XENON Collaboration , E. Aprile , J. Aalbers , F. Agostini , M. Alfonsi , F. D. Amaro , M. Anthony , F. Arneodo , P. Barrow , L. Baudis , B. Bauermeister , M. L. Benabderrahmane , T. Berger , P. A. Breur , A. Brown , E. Brown , S. Bruenner , G. Bruno , R. Budnik , L. Butikofer , J. Calven , J. M. R. Cardoso , M. Cervantes , D. Cichon , D. Coderre , A. P. Colijn , J. Conrad , J. P. Cussonneau , M. P. Decowski , P. dePerio , P. DiGangi , A. DiGiovanni , S. Diglio , E. Duchovni , G. Eurin , J. Fei , A. D. Ferella , A. Fieguth , D. Franco , W. Fulgione , A. Gallo Rosso , M. Galloway , F. Gao , M. Garbini , C. Geis , L. W. Goetzke , L. Grandi , Z. Greene , C. Grignon , C. Hasterok , E. Hogenbirk , R. Itay , B. Kaminsky , G. Kessler , A. Kish , H. Landsman , R. F. Lang , D. Lellouch , L. Levinson , M. LeCalloch , Q. Lin , S. Lindemann , M. Lindner , J. A. M. Lopes , A. Manfredini , I. Maris , T. Marrodan Undagoitia , J. Masbou , F. V. Massoli , D. Masson , D. Mayani , Y. Meng , M. Messina , K. Micheneau , B. Miguez , A. Molinario , M. Murra , J. Naganoma , K. Ni , U. Oberlack , S. E. A. Orrigo , P. Pakarha , B. Pelssers , R. Persiani , F. Piastra , J. Pienaar , M. -C. Piro , G. P lante , N. Priel , L. Rauch , S. Reichard , C. Reuter , A. Rizzo , S. Rosendahl , N. Rupp , R. Saldanha , J. M. F. dosSantos , G. Sartorelli , M. Scheibelhut , S. Schindler , J. Schreiner , M. Schumann , L. Scotto Lavina , M. Selvi , P. Shagin , E. Shockley , M. Silva , H. Simgen , M. v. Sivers , A. Stein , D. Thers , A. Tiseni , G. Trinchero , C. Tunnell , N. Upole , H. Wang , Y. Wei , C. Weinheimer , J. Wulf , J. Ye , Y. Zhang

We describe the purification of xenon from traces of the radioactive noble gas radon using a cryogenic distillation column. The distillation column is integrated into the gas purification loop of the XENON100 detector for online radon…

仪器与探测器 · 物理学 2017-06-05 XENON Collaboration , E. Aprile , J. Aalbers , F. Agostini , M. Alfonsi , F. D. Amaro , M. Anthony , F. Arneodo , P. Barrow , L. Baudis , B. Bauermeister , M. L. Benabderrahmane , T. Berger , P. A. Breur , A. Brown , E. Brown , S. Bruenner , G. Bruno , R. Budnik , L. Bütikofer , J. Calvén , J. M. R. Cardoso , M. Cervantes , D. Cichon , D. Coderre , A. P. Colijn , J. Conrad , J. P. Cussonneau , M. P. Decowski , P. de Perio , P. Di Gangi , A. Di Giovanni , S. Diglio , E. Duchovni , G. Eurin , J. Fei , A. D. Ferella , A. Fieguth , D. Franco , W. Fulgione , A. Gallo Rosso , M. Galloway , F. Gao , M. Garbini , C. Geis , L. W. Goetzke , L. Grandi , Z. Greene , C. Grignon , C. Hasterok , E. Hogenbirk , R. Itay , B. Kaminsky , G. Kessler , A. Kish , H. Landsman , R. F. Lang , D. Lellouch , L. Levinson , M. Le Calloch , Q. Lin , S. Lindemann , M. Lindner , J. A. M. Lopes A. Manfredini , I. Maris , T. Marrodán Undagoitia , J. Masbou , F. V. Massoli , D. Masson , D. Mayani , Y. Meng , M. Messina , K. Micheneau , B. Miguez , A. Molinario , M. Murra , J. Naganoma , K. Ni , U. Oberlack , S. E. A. Orrigo , P. Pakarha , B. Pelssers , R. Persiani , F. Piastra , J. Pienaar , M. -C. Piro , V. Pizzella , G. Plante , N. Priel , L. Rauch , S. Reichard , C. Reuter , A. Rizzo , S. Rosendahl , N. Rupp , R. Saldanha , J. M. F. dos Santos , G. Sartorelli , M. Scheibelhut , S. Schindler , J. Schreiner , M. Schumann , L. Scotto Lavina , M. Selvi , P. Shagin , E. Shockley , M. Silva , H. Simgen , M. v. Sivers , A. Stein , D. Thers , A. Tiseni , G. Trinchero , C. Tunnell , N. Upole , H. Wang , Y. Wei , C. Weinheimer , J. Wulf , J. Ye , Y. Zhang , I. Cristescu

The selection of low-radioactive construction materials is of utmost importance for the success of low-energy rare event search experiments. Besides radioactive contaminants in the bulk, the emanation of radioactive radon atoms from…

仪器与探测器 · 物理学 2022-02-04 E. Aprile , J. Aalbers , F. Agostini , M. Alfonsi , L. Althueser , F. D. Amaro , V. C. Antochi , E. Angelino , J. R. Angevaare , F. Arneodo , D. Barge , L. Baudis , B. Bauermeister , L. Bellagamba , M. L. Benabderrahmane , T. Berger , P. A. Breur , A. Brown , E. Brown , S. Bruenner , G. Bruno , R. Budnik , C. Capelli , J. M. R. Cardoso , D. Cichon , B. Cimmino , M. Clark , D. Coderre , A. P. Colijn , J. Conrad , J. P. Cussonneau , M. P. Decowski , A. Depoian , P. Di Gangi , A. Di Giovanni , R. Di Stefano , S. Diglio , A. Elykov , G. Eurin , A. D. Ferella , W. Fulgione , P. Gaemers , R. Gaior , A. Gallo Rosso , M. Galloway , F. Gao , L. Grandi , M. Garbini , C. Hasterok , C. Hils , K. Hiraide , L. Hoetzsch , E. Hogenbirk , J. Howlett , M. Iacovacci , Y. Itow , F. Joerg , N. Kato , S. Kazama , M. Kobayashi , G. Koltman , A. Kopec , H. Landsman , R. F. Lang , L. Levinson , Q. Lin , S. Lindemann , M. Lindner , F. Lombardi , J. A. M. Lopes , E. López Fune , C. Macolino , J. Mahlstedt , L. Manenti , A. Manfredini , F. Marignetti , T. Marrodán Undagoitia , K. Martens , J. Masbou , D. Masson , S. Mastroianni , M. Messina , K. Miuchi , A. Molinario , K. Morå , S. Moriyama , Y. Mosbacher , M. Murra , J. Naganoma , K. Ni , U. Oberlack , K. Odgers , J. Palacio , B. Pelssers , R. Peres , J. Pienaar , V. Pizzella , G. Plante , J. Qin , H. Qiu , D. Ramírez García , S. Reichard , A. Rocchetti , N. Rupp , J. M. F. dos Santos , G. Sartorelli , N. Šarčević , M. Scheibelhut , S. Schindler , J. Schreiner , D. Schulte , M. Schumann , L. Scotto Lavina , M. Selvi , F. Semeria , P. Shagin , E. Shockley , M. Silva , H. Simgen , A. Takeda , C. Therreau , D. Thers , F. Toschi , G. Trinchero , C. Tunnell , M. Vargas , G. Volta , O. Wack , H. Wang , Y. Wei , C. Weinheimer , M. Weiss , D. Wenz , J. Westermann , C. Wittweg , J. Wulf , Z. Xu , M. Yamashita , J. Ye , G. Zavattini , Y. Zhang , T. Zhu , J. P. Zopounidis

The Karlsruhe Tritium Neutrino (KATRIN) experiment investigating tritium beta-decay close to the endpoint with unprecedented precision has stringent requirements on the background level of less than 10^(-2) counts per second. Electron…

仪器与探测器 · 物理学 2015-06-15 N. Wandkowsky , G. Drexlin , F. M. Fränkle , F. Glück , S. Groh , S. Mertens

The activity of $^{222}$Rn and its daughter isotopes was measured in the air of several underground laboratories of the Baksan Neutrino Observatory at various distances from the entrance. The measurements were carried out with the help of…

Experiments searching for weakly interacting massive particle dark matter are now detecting background events from solar neutrino-electron scattering. However, the dominant background in state-of-the-art experiments such as LZ and XENONnT…

高能物理 - 实验 · 物理学 2023-12-27 H. Chen , R. Gibbons , S. J. Haselschwardt , S. Kravitz , Q. Xia , P. Sorensen

The KATRIN experiment is designed to measure the absolute neutrino mass scale with a sensitivity of 200 meV at 90% C.L. by high resolution tritium beta-spectroscopy. A low background level of 10 mHz at the beta-decay endpoint is required in…

The decay of common radioactive gases, such as radon, produces stable isotopes by a sequence of daughter particles with varied half-lives. These daughter particles are a significant source of gamma, neutron, and alpha particle backgrounds…

仪器与探测器 · 物理学 2015-09-02 M. Bruemmer , M. Nakib , R. Calkins , J. Cooley , S. Sekula

Radioactive radon atoms originating from the long-lived primordial $^{238}\mathrm{U}$ and $^{232}\mathrm{Th}$ decay chains are constantly emanated from the surfaces of most materials. The radon atoms and their radioactive daughter isotopes…

仪器与探测器 · 物理学 2024-01-30 D. Wiebe , S. Lindemann , M. Schumann

Krypton-85 is an anthropogenic beta-decaying isotope which produces low energy backgrounds in dark matter and neutrino experiments, especially those based upon liquid xenon. Several technologies have been developed to reduce the Kr…

仪器与探测器 · 物理学 2017-04-26 D. Yu. Akimov , A. I. Bolozdynya , A. A. Burenkov , C. Hall , A. G. Kovalenko , V. V. Kuzminov , G. E. Simakov

The KATRIN experiment will determine the effective electron anti-neutrino mass with a sensitivity of 200 meV/c$^2$ at 90% CL. The energy analysis of tritium $\beta$-decay electrons will be performed by a tandem setup of electrostatic…

Radioactive noble gas radon ($\mathrm{^{222}Rn}$) is one of the major background sources below the MeV region in rare event search experiments. To precisely measure radon concentration in purified gases, a radon detector with an…

仪器与探测器 · 物理学 2021-12-14 K. Okamoto , Y. Nakano , G. Pronost , H. Sekiya , S. Tasaka , Y. Takeuchi , M. Nakahata
‹ 上一页 1 2 3 10 下一页 ›