相关论文: Time resolution of silicon pixel sensors
In typical nuclear physics experiments with radioactive ion beams (RIBs) selected by the in-flight separation technique, Si detectors or ionization chambers are usually equipped for the charge determination of RIBs. The obtained charge…
Resistive Plate Chamber (RPC) is a gaseous detector, known for its good spatial resolution and excellent time resolution. Due to its fast response and excellent time resolution, it is used for both triggering and timing purpose. But the…
Three-dimensional (3D) pixel sensors are a promising technology for implementing the 4D-tracking paradigm in high-radiation environments. Despite their advantages in radiation tolerance, 3D pixel sensors exhibit non-uniform electric and…
Photon number resolving detectors are needed for a variety of applications including linear-optics quantum computing. Here we describe the use of time-multiplexing techniques that allows ordinary single photon detectors, such as silicon…
This contribution investigates a prototype of a TPC readout with a highly pixelated CMOS ASIC, which is an option for charged particles tracking of the ILC. A triple GEM stack was joined with a TimePix and MediPix2 chip (pixel size of…
We characterized the front-end electronics used to process high-frequency signals from low-gain avalanche diodes (LGADs) at the Fermilab Test Beam Facility. LGADs are silicon detectors employed for charged particle tracking, offering…
The possibilty of performing high-rate calorimetry with a slow scintillator crystal is studied. In this experimental situation, to avoid pulse pile-up, it can be necessary to base the energy measurement on only a fraction of the emitted…
A high-precision charge measurement can be achieved by the area integration of a digitized quasi-Gaussian signal after the signal passes through the shaper and analog-to-digital converter (ADC). The charge measurement contains an error due…
The energy loss of charged particles in silicon can be approximated by a simple analytical model. With help of measured charge deposits in individual channels of hit clusters their position and energy can be estimated. Deposits below…
A readout electronic with high time and energy resolution performance is designed for the SDD (Silicon Drift Detector) signals readout, which is aimed for X-ray pulsar based navigation (XNAV). For time measurement, the input signal is fed…
A photon-counting silicon strip detector with two energy thresholds was investigated for spectral X-ray imaging in a mammography system. Preliminary studies already indicate clinical benefit of the detector, and the purpose of the present…
Silicon tracking detectors provide excellent spatial resolution, and so can provide excellent momentum resolution for energetic charged particles, even in compact detectors. However, at lower momenta, multiple scattering in the silicon…
In this work we attempt to establish the best time resolution attainable with a scintillation counter consisting of a plastic scintillator read out by a Geiger-mode Avalanche Photodiode. The measured time resolution is inversely…
A technique for improving the momentum resolution for low momentum charged particles in few layer silicon based trackers is presented. The particle momenta are determined from the measured Landau dE/dx distribution and the Bethe-Bloch…
Using multi-channel time-resolved current measurements (multi TCT), the charge collection of p+n silicon strip sensors for electron-hole pairs produced close to the Si-SiO2 interface by a focussed sub-nanosecond laser with a wavelength of…
In this work we investigated a method to determine time walk in an active silicon pixel sensor prototype using Edge-TCT with infrared laser charge injection. Samples were investigated before and after neutron irradiation to 5e14 neq/cm2.…
The Time Projection Chamber (TPC) can identify particle species using the energy loss (dE/dx) measured by the readout pad rows. The dE/dx resolution for the ILD (International Large Detector) -TPC for the International Linear Collider…
The performance of novel n-in-p planar pixel detectors, designed for future upgrades of the ATLAS Pixel system is presented. The n-in-p silicon sensors technology is a promising candidate for the pixel upgrade thanks to its radiation…
Novel event-based electron detector platforms provide an avenue to extend the temporal resolution of electron microscopy into the ultrafast domain. Here, we characterize the timing accuracy of a detector based on a TimePix3 architecture…
We have developed a neutron imaging sensor based on an INTPIX4-SOI pixelated silicon device. Neutron irradiation tests are performed at several neutron facilities to investigate sensor's responses for neutrons. Detection efficiency is…