相关论文: A beam monitor using silicon pixel sensors for had…
Particle therapy is a well established clinical treatment of tumors. More than one hundred particle therapy centers are in operation world wide. The advantage of using hadrons like protons or carbon ions as particles for tumor irradiation…
A prototype plastic scintillating fibre based beam profile monitor was tested at the Heidelberg Ion Therapy Centre / \textit{Heidelberg Ionenstrahl Therapiezentrum} (HIT) in 2016 to determine its beam property reconstruction performance and…
A gaseous beam monitor utilizing gas electron multiplier (GEM) and pixel sensors is being developed for the Cooling Storage Ring (CSR) External-target Experiment (CEE) at Heavy Ion Research Facility in Lanzhou (HIRFL). The beam monitor is…
In ion cancer therapy, high-intensity ion beams are used to treat tumors by taking advantage of the Bragg-Peak. Typical ion therapy centers use particle rates up to $10^{10}$ ions/second for treatment. On the other hand, such intensities…
Particle therapy is a well-established clinical treatment of tumors and so far, more than one hundred centers are in operation around the world. High accuracy on position and dose rate in beam monitoring are major cornerstones of clinical…
A compact beam-profile monitor was constructed using a linear contact image sensor attached to a plastic scintillator and tested using a 230 MeV proton beam. The results indicate that the beam distribution can be obtained in real-time, and…
Building on the demonstrated sensitivity of the Heavy Ion Monitor on a Chip (HIMoC) presented in Part I of this work, we performed additional irradiation exposures using 24.8 MeV/u beams of $^{14}$N, $^{22}$Ne, and $^{40}$Ar at the Texas…
Accurate control and monitoring of the beam is essential for precise dose delivery to tumor tissues during radiotherapy. Real-time monitoring of ion beam profiles and positions improves beam control, patient safety, and treatment…
\textit{Topmetal-${II}^-$} is a highly pixelated direct charge sensor that contains a 72${\times}$72 pixel array of 83${\mu}$m pitch size. The key feature of \textit{Topmetal-${II}^-$} is that it can directly collect charges via metal nodes…
The performance of a particle detector derived from nitride read-only memory (NROM) technology is evaluated, with immediate applications in space-based heavy ion radiation monitoring and detection. Irradiation exposures are performed using…
We present an innovative charge detector with high resolution and wide dynamic range designed to fulfill the requirements of a monitoring system for a high energy ion beam. The detector prototype, constructed using Si photodiodes and a…
In this paper, we study how pixel size influences energy resolution for a proposed pixelated detector---a high sensitivity, low cost, and real-time radon monitor based on \textit{Topmetal-${II}^-$} time projection chamber (TPC). Using…
A high-performance Scintillator Ion Beam Monitor (SIBM) provides diagnostics across a range of isotopes, energies, and intensities employing a machine-vision camera with two novel scintillator targets movable into/out of the beam without…
Synchrotron radiation with the characteristic of high brilliance, high level of polarization, high collimation, low emittance and wide tunability in energy has been used as a standard source in metrology(1, 2). For a decade, lots of…
Charged Particle Therapy is a technique for cancer treatment that exploits hadron beams, mostly protons and carbons. A critical issue is the monitoring of the dose released by the beam to the tumor and to the surrounding tissues. We present…
A high precision beam monitor system based on silicon carbide PIN sensor is designed for China Spallation Neutron Source 1.6 GeV proton beam to monitor the proton beam fluence.The concept design of the beam monitor system is finished…
We report the design and characterization of a CMOS pixel direct charge sensor, Topmetal-II-, fabricated in a standard 0.35um CMOS Integrated Circuit process. The sensor utilizes exposed metal patches on top of each pixel to directly…
In superconducting linear accelerators (linacs), accurately monitoring beam dynamics is essential for minimizing beam losses and ensuring stable operations. However, destructive diagnostics must be avoided in superconducting sections to…
Using industrial standard 0.35{\mu}m CMOS Integrated Circuit process, we realized a highly pixelated sensor that directly collects charge via metal nodes placed on the top of each pixel and forms two dimensional images of charge cloud…
For the purpose of withstanding very high radiation doses, silicon pixel sensors with a 3D electrode geometry are being developed. Detectors of this kind are highly interesting for harch radiation environments such as expected in the High…