ATLAS 阻性板室在 X5-GIF 的老化测试
仪器与探测器
2009-11-10 v2
摘要
在 CERN 辐照设施 X5-GIF,正对三个 ATLAS 量产 RPC 站进行老化测试。利用由闪烁体描迹仪触发的宇宙线监测室效率。当 X5 μ 子束可用时进行更高统计量的测量。我们在此报道不同源强下效率随工作电压的变化测量,最高计数率约为 700Hz/cm^2。我们描述了测试期间室的性能,直至总体老化达 4 个 ATLAS 等效年,对应 0.12C/cm^2 的积分电荷,其中包含 5 倍安全系数。
引用
@article{arxiv.physics/0410264,
title = {Ageing test of the ATLAS RPCs at X5-GIF},
author = {G. Aielli and M. Alviggi and V. Ammosov and M. Biglietti and P. Camarri and V. Canale and M. Caprio and R. Cardarelli and G. Carlino and G. Cataldi and G. Chiodini and F. Conventi and R. de Asmundis and M. Della Pietra and D. Della Volpe and A. Di Ciaccio and A. Di Simone and L. Di Stante and E. Gorini and F. Grancagnolo and P. Iengo and B. Liberti and A. Nisati and Fr. Pastore and E. Pastori and S. Patricelli and R. Perrino and M. Primavera and R. Santonico and G. Sekhniaidze and S. Spagnolo and Yu. Sviridov and R. Vari and S. Veneziano and V. Zaets},
journal= {arXiv preprint arXiv:physics/0410264},
year = {2009}
}
备注
4 pages. Presented at the VII Workshop on Resistive Plate Chambers and Related Detectors; Clermont-Ferrand October 20th-22nd, 2003