相关论文: Development of a two-dimensional virtual pixel X-r…
The VOXES project's goal is to realize the first prototype of a high resolution and high precision X-ray spectrometer for diffused sources, using Highly Annealed Pyrolitic Graphite (HAPG) crystals combined with precision position detectors.…
AXEL is a high pressure xenon gas TPC detector being developed for neutrinoless double-beta decay search. We use the proportional scintillation mode with a new electroluminescence light detection system to achieve high energy resolution in…
NEXT-DEMO is a large-scale prototype of the NEXT-100 detector, an electroluminescent time projection chamber that will search for the neutrinoless double beta decay of Xe-136 using 100 to 150 kg of enriched xenon gas. NEXT-DEMO was built to…
For reconstruction of the spatial structure of many-component objects, it is proposed to use multi-radiography with detection of X-ray by combined detector arrays using detectors of ``scintillator-photodiode'' type. A theoretical model has…
This works reports on gaseous detectors developments made in the frame of the EXO double-beta decay experiment. LEM (Large Electron Multiplication) are electron amplification grids based on GEM. They were developed in Neuchatel and showed…
The use of structured ultrashort pulses with coupled spatiotemporal properties is emerging as a key tool for ultrafast manipulation. Ultrafast vector beams are opening exciting opportunities in different fields such as microscopy,…
Detector developments are currently enabling new capabilities in the field of transmission electron microscopy (TEM). We have investigated the limits of a hybrid pixel detector, Medipix3, to record dynamic, time varying, electron signals.…
AXEL is a high-pressure xenon gas time projection chamber for neutrinoless double-beta decay (0n2b) search. The AXEL has a unique readout system called ELCC which has a cellular structure and photosensors to detect electroluminescence light…
Position sensitive detectors based on gaseous scintillation proportional counters with Anger-type readout are being used in several research areas such as neutron detection, search for dark matter and neutrinoless double beta decay. Design…
The performance of hybrid GaAs pixel detectors as X-ray imaging sensors were investigated at room temperature. These hybrids consist of 300 mu-m thick GaAs pixel detectors, flip-chip bonded to a CMOS Single Photon Counting Chip (PCC). This…
The High Energy Physics group of the University of Texas at Arlington Physics Department has been developing Gas Electron Multiplier (GEM) detectors for use as the sensitive gap detector in digital hadron calorimeters (DHCAL) for the future…
Study of the stability of gain and energy resolution for a triple GEM detector has been performed under continuous radiation of X-ray with high rate, using premixed gas of Argon and CO$_2$ in 70/30 ratio and conventional NIM electronics. A…
When an X-ray area detector based on a single crystalline material, for instance, a state of the art hybrid pixel detector, is illuminated from a point source by monochromatic radiation, a pattern of lines appears which overlays the…
Ghost tomography using single-pixel detection extends the emerging field of ghost imaging to three dimensions, with the use of penetrating radiation. In this work, a series of spatially random x-ray intensity patterns is used to illuminate…
We assess the performance of different protocols for simulating excited-state X-ray absorption spectra. We consider three different protocols based on equation-of-motion coupled-cluster singles and doubles, two of them combined with the…
We report on the development of a large-volume, wide field-of-view time projection chamber (TPC) for X-ray polarimetry, featuring a triple-GEM amplification stage and optical readout. Originally developed within the CYGNO program for…
In order to fully exploit the Physics potential of future e+ e- linear collider, a Vertex Detector providing high resolution track reconstruction is required. Hybrid Silicon pixel detectors are an attractive option for the sensor technology…
The gas gain and energy resolution of single and double THGEM detectors (5{\times}5cm2 effective area) with mini-rims (rim is less than 10{\mu}m) were studied. The maximum gain can reach 5{\times}103 and 2{\times}105 for single and double…
This experimental particle-physics thesis reports the latest developments on the GasPM, a novel gaseous photodetector aimed at suppressing beam-induced backgrounds in the electromagnetic calorimeter for a potential upgrade of the Belle~II…
The continuing improvement in quantum efficiency (above 90% for single visible photons), reduction in noise (below 1 electron per pixel), and shrink in pixel pitch (less than 1 micron) motivate billion-pixel X-ray cameras (BiPC-X) based on…