相关论文: Development of a two-dimensional virtual pixel X-r…
We present the results of our recent studies on a Thick Gas Electron Multiplier (THGEM)-based imaging detector prototype. It consists of two 100x100 mm^2 THGEM electrodes in cascade, coupled to a resistive anode. The event location is…
The long-term stability in terms of gain and energy resolution of a prototype triple Gas Electron Multiplier (GEM) detector has been investigated with high rate X-ray irradiation. Premixed Ar/CO2 (80:20) and (90:10) gases have been used for…
The European X-ray Free Electron Laser (XFEL.EU) will provide unprecedented peak brilliance and ultra-short and spatially coherent X-ray pulses in an energy range of 0.25 to 25 keV . The pulse timing structure is unique with a burst of 2700…
We demonstrate experimentally the ability to use a single pixel detector for two-dimensional high-speed and high-resolution x-ray imaging. We image the rotation of a spinning chopper at 100-kHz at spatial resolution of about 15 microns by…
A high-pressure xenon gas time projection chamber, with a unique cellular readout structure based on electroluminescence, has been developed for a large-scale neutrinoless double-beta decay search. In order to evaluate the detector…
Optical readout of GEM based devices by means of high granularity and low noise CMOS sensors allows to obtain very interesting tracking performance. Space resolution of the order of tens of $\mu$m were measured on the GEM plane along with…
An X-ray detector based on the combination of an integrated Micromegas stage with a pixel chip has been built in order to be installed at the CERN Axion Solar Telescope. Due to its high granularity and spatial resolution this detector…
We have developed a prototype time-resolved neutron imaging detector employing the micro-pixel chamber (muPIC), a micro-pattern gaseous detector, coupled with a field programmable gate array-based data acquisition system for applications in…
The design and tests of Timing Counter elements for the upgrade of the MEG experiment, MEG II,is presented. The detector is based on several small plates of scintillator with a Silicon PhotoMultipliers dual-side readout. The optimisation of…
Photosensitive gaseous detectors with a simple photoelectron multiplication mechanism as resistive plate chambers are expected to offer both large photo coverage and excellent time resolution while keeping costs low. We have developed a…
The Liquid Xenon Gamma-Ray Imaging Telescope (LXeGRIT) is the first realization of a liquid xenon time projection chamber for Compton imaging of MeV gamma-ray sources in astrophysics. By measuring the energy deposit and the three spatial…
Xenon, in both its gaseous and liquid phase, offers excellent scintillation and ionization properties, making it an ideal target medium for rare event searches. We report on measurements performed with a dual-phase xenon time projection…
The construction of low mass vertex detectors with a high level of system integration is of great interest for next generation collider experiments. Radiation length images with a sufficient spatial resolution can be used to measure and…
We report on the systematic study of a single-gas-electron-multiplication (GEM) loaded gaseous detector developed for precision measurements of high-energy particle beams and dose-verification measurements. In the present study, a…
The spectrum of laser-plasma generated X-rays is very important, it characterizes electron dynamics in plasma and is basic for applications. However, the accuracies and efficiencies of existing methods to diagnose the spectrum of…
In this work, we present a novel approach to photothermal super resolution based thermographic resolution of internal defects using two-dimensional pixel pattern-based active photothermal laser heating in conjunction with subsequent…
The micropattern gaseous detector Micromegas has been developed for several years in Saclay and presents good performance for neutron detection. A prototype for neutron imaging has been designed and new results obtained in thermal neutron…
A series of beam tests were conducted at the KEK AR test beamline in ordet to investigate the performance of a prototype detector for instrumentation in the low-E beamline at the CERN H2 line. For the silicon strip detector, the…
The performance of several trigger counters based on plastic scintillators with silicon photomultiplier readout is investigated with cosmic rays. Efficiency and time resolution are measured using digital waveform analysis. The obtained…
Gas Electron Multiplier (GEM) is a cutting edge Micro Pattern Gaseous detector (MPGD) technology suitable as tracking device in high rate Heavy-Ion (HI) experiments for their good spatial resolution and most importantly high rate handling…