中文
相关论文

相关论文: A Textured Silicon Calorimetric Light Detector

200 篇论文

We summarize the recent activity of our group in the calibration, monitoring and gain stabilization of photodetectors, primarily silicon photomultipliers, in calorimeters using scintillator as active medium. The task originally solved for…

仪器与探测器 · 物理学 2015-03-25 J. Cvach , M. Janata , M. Kovalcuk , J. Kvasnicka , I. Polak , J. Smolik

We have combined two low-threshold detector technologies to develop a large-mass, low-threshold detector system that simultaneously measures the athermal phonons in a sapphire detector while an adjacent silicon high-voltage detector detects…

When heated, micro-resonators present a shift of their resonance frequencies. We study specifically silicon cantilevers heated locally by laser absorption, and evaluate theoretically and experimentally their temperature profile and its…

材料科学 · 物理学 2021-06-02 Basile Pottier , Felipe Aguilar , Mickaël Geitner , Francisco Melo , Ludovic Bellon

We report on the simulation results for the angular resolution of an electromagnetic (EM) sampling calorimeter with photons in the range of 100~MeV to 2~GeV. The simulation model of the EM calorimeter consists of alternating layers of a…

仪器与探测器 · 物理学 2023-04-26 Junlee Kim , Eun-Joo Kim , YoungJun Kim , JungKeun Ahn , GeiYoub Lim

X-ray detectors made of crystalline silicon have several advantages including low dark currents, fast charge collection and high energy resolution. For high-energy x-rays, however, silicon suffers from its low atomic number, which might…

仪器与探测器 · 物理学 2021-01-26 Moa Yveborg , Cheng Xu , Erik Fredenberg , Mats Danielsson

We measured a considerable increase of the emitted radiation by 120 GeV/c electrons in an axially oriented lead tungstate scintillator crystal, if compared to the case in which the sample was not aligned with the beam direction. This…

Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work presents systematic reflectivity studies of Silicon…

仪器与探测器 · 物理学 2021-09-01 M. Wagenpfeil , T. Ziegler , J. Schneider , A. Fieguth , M. Murra , D. Schulte , L. Althueser , C. Huhmann , C. Weinheimer , T. Michel , G. Anton , G. Adhikari , S. Al Kharusi , E. Angelico , I. J. Arnquist , I. Badhrees , J. Bane , D. Beck , V. Belov , T. Bhatta , A. Bolotnikov , P. A. Breur , J. P. Brodsky , E. Brown , T. Brunner , E. Caden , G. F. Cao , C. Chambers , B. Chana , S. A. Charlebois , D. Chernyak , M. Chiu , B. Cleveland , A. Craycraft , T. Daniels , L. Darroch , A. Der Mesrobian-Kabakian , A. de St Croix , K. Deslandes , R. DeVoe , M. L. Di Vacri , M. J. Dolinski , J. Echevers , M. Elbeltagi , L. Fabris , D. Fairbank , W. Fairbank , J. Farine , S. Ferrara , S. Feyzbakhsh , G. Gallina , P. Gautam , G. Giacomini , C. Gingras , D. Goeldi , A. Gorham , R. Gornea , G. Gratta , E. V. Hansen , C. A. Hardy , K. Harouaka , M. Heffner , E. W. Hoppe , A. House , M. Hughes , A. Iverson , A. Jamil , M. Jewell , A. Karelin , L. J. Kaufman , R. Krücken , A. Kuchenkov , K. S. Kumar , Y. Lan , A. Larson , K. G. Leach , D. S. Leonard , G. Li , S. Li , Z. Li , C. Licciardi , R. Lindsay , R. MacLellan , P. Martel-Dion , N. Massacret , T. McElroy , M. Medina Peregrina , B. Mong , D. C. Moore , K. Murray , J. Nattress , C. R. Natzke , R. J. Newby , F. Nolet , O. Nusair , J. C. Nzobadila Ondze , K. Odgers , A. Odian , J. L. Orrell , G. S. Ortega , I. Ostrovskiy , C. T. Overman , S. Parent , A. Piepke , A. Pocar , J. -F. Pratte , E. Raguzin , G. J. Ramonnye , H. Rasiwala , S. Rescia , F. Retière , C. Richard , M. Richman , J. Ringuette , A. Robinson , T. Rossignol , P. C. Rowson , N. Roy , R. Saldanha , S. Sangiorgio , A. K. Soma , F. Spadoni , V. Stekhanov , T. Stiegler , M. Tarka , S. Thibado , A. Tidball , J. Todd , T. Totev , S. Triambak , R. Tsang , F. Vachon , V. Veeraraghavan , S. Viel , C. Vivo-Vilches , M. Walent , U. Wichoski , M. Worcester , S. X. Wu , Q. Xia , W. Yan , L. Yang , O. Zeldovich

CryoCsI, the proposed prototype, is a cryogenic undoped CsI scintillating detector, which has a much lower energy threshold potentially down to 0.5 keV$_{nr}$ compared to the doped CsI. This enhanced sensitivity of CryoCsI allows for the…

仪器与探测器 · 物理学 2024-05-31 Keyu Ding

Single-photon imaging spectrometers of high quantum efficiency in the infrared to ultraviolet wavelength range, with good timing resolution and with a vanishing dark count rate are on top of the wish list in earth-bound astronomy, material…

仪器与探测器 · 物理学 2007-06-13 Miha Furlan , Eugenie Kirk , Alex Zehnder

The photosensitivity of silicon is inherently very low in the visible electromagnetic spectrum, and it drops rapidly beyond 800 nm in near-infrared wavelengths. Herein, we have experimentally demonstrated a technique utilizing…

We have developed a custom amplifier board coupled to a large-format 16-channel Hamamatsu silicon photomultiplier device for use as the light sensor for the electromagnetic calorimeters in the Muon g-2 experiment at Fermilab. The…

The photon trapping nano-structures help to enhance quantum efficiency and reduce reflection for MSM photodetector that allows fast Si photodetectors at wavelength 800-950nm. The nanostructure consist of micro holes reduces reflection and…

By patterning a freestanding dielectric membrane into a photonic crystal reflector (PCR), it is possible to resonantly enhance its normal-incidence reflectivity, thereby realizing a thin, single-material mirror. In many PCR applications,…

The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the hadronic calorimeter, one option is a highly granular sampling…

仪器与探测器 · 物理学 2012-08-08 C. Adloff , J. Blaha , J. -J. Blaising , C. Drancourt , A. Espargilière , R. Gaglione , N. Geffroy , Y. Karyotakis , J. Prast , G. Vouters , K. Francis , J. Repond , J. Smith , L. Xia , E. Baldolemar , J. Li , S. T. Park , M. Sosebee , A. P. White , J. Yu , Y. Mikami , N. K. Watson T. Goto , G. Mavromanolakis , M. A. Thomson , D. R. Ward W. Yan , M. Benyamna , C. Cârloganu , F. Fehr , P. Gay , S. Manen , L. Royer , G. C. Blazey , A. Dyshkant , J. G. R. Lima , V. Zutshi , J. -Y. Hostachy , L. Morin , U. Cornett , D. David , R. Fabbri , G. Falley , K. Gadow , E. Garutti , P. Göttlicher , C. Günter , S. Karstensen , F. Krivan , A. -I. Lucaci-Timoce , S. Lu , B. Lutz , I. Marchesini , N. Meyer , S. Morozov , V. Morgunov , M. Reinecke , F. Sefkow , P. Smirnov , M. Terwort , A. Vargas-Trevino , N. Wattimena , O. Wendt , N. Feege , J. Haller , S. Richter , J. Samson P. Eckert , A. Kaplan , H. -Ch. Schultz-Coulon , W. Shen , R. Stamen , A. Tadday , B. Bilki , E. Norbeck , Y. Onel , G. W. Wilson , K. Kawagoe , S. Uozumi , J. A. Ballin , P. D. Dauncey , A. -M. Magnan , H. S. Yilmaz , O. Zorba , V. Bartsch , M. Postranecky , M. Warren , M. Wing , F. Salvatore , E. Calvo Alamillo , M. -C. Fouz , J. Puerta-Pelayo , V. Balagura , B. Bobchenko , M. Chadeeva , M. Danilov , A. Epifantsev , O. Markin , R. Mizuk , E. Novikov , V. Rusinov , E. Tarkovsky , Y. Soloviev , V. Kozlov , P. Buzhan , B. Dolgoshein , A. Ilyin , V. Kantserov , V. Kaplin , A. Karakash , E. Popova , S. Smirnov , A. Frey , C. Kiesling , K. Seidel , F. Simon , C. Soldner , L. Weuste , J. Bonis , B. Bouquet , S. Callier , P. Cornebise , Ph. Doublet , F. Dulucq , M. Faucci Giannelli , J. Fleury , G. Guilhem , H. Li , G. Martin-Chassard , F. Richard , Ch. de la Taille , R. Pöschl , L. Raux , N. Seguin-Moreau , F. Wicek , M. Anduze , V. Boudry , J-C. Brient , D. Jeans , P. Mora de Freitas , G. Musat , M. Reinhard , M. Ruan , H. Videau , B. Bulanek , J. Zacek , J. Cvach , P. Gallus , M. Havranek , M. Janata , J. Kvasnicka , D. Lednicky , M. Marcisovsky , I. Polak , J. Popule , L. Tomasek , M. Tomasek , P. Ruzicka , P. Sicho , J. Smolik , V. Vrba , J. Zalesak , B. Belhorma , H. Ghazlane , K. Kotera , M. Nishiyama , T. Takeshita , S. Tozuka , T. Buanes , G. Eigen

In nuclear, particle and astroparticle physics experiments, calorimeters are used to measure the properties of particles with kinetic energies that range from a fraction of 1 eV to 10^20 eV or more. These properties are not necessarily…

仪器与探测器 · 物理学 2018-10-17 Richard Wigmans

A prototype for a sampling calorimeter made out of cerium fluoride crystals interleaved with tungsten plates, and read out by wavelength-shifting fibres, has been exposed to beams of electrons with energies between 20 and 150 GeV, produced…

By photothermomodulatoin method the comparative study of thermal diffusivity of absorbing coating for sensitive elements of pyroelectric detectors of radiation formed from metal dispersion layer blacks, dielectric paint blacks and carbon…

Dark matter direct detection experiments are designed to look for the scattering of dark matter particles that are assumed to move with virial velocities $\sim 10^{-3}$. At these velocities, the energy deposition in the detector is large…

高能物理 - 唯象学 · 物理学 2022-08-12 Julien Billard , Matt Pyle , Surjeet Rajendran , Harikrishnan Ramani

We present the results of a test beam campaign on a capillary-tube fibre-based dual-readout calorimeter, designed for precise hadronic and electromagnetic energy measurements in future collider experiments. The calorimeter prototype…

In order to assess the performance of liquid xenon detectors for use in positron emission tomography we studied the scintillation light and ionization charge produced by 511 keV photons in a small prototype detector. Scintillation light was…

仪器与探测器 · 物理学 2009-09-24 P. Amaudruz , D. Bryman , L. Kurchaninov , P. Lu , C. Marshal , J. P. Martin , A. Muennich , F. Retiere , A. Sher