中文

钨-氟化铈取样量能器在高能电子束测试中的性能

仪器与探测器 2015-12-09 v1 高能物理 - 实验

摘要

一个由氟化铈晶体与钨板交替排列、并通过波长位移光纤读出的取样量能器原型,已暴露在由 CERN 超级质子同步加速器复合体产生的能量在 20 至 150 GeV 之间的电子束中。介绍了该原型的性能,并与该装置的 Geant4 模拟进行了比较。特别强调了通道前表面的响应均匀性以及原型的能量分辨率。

关键词

引用

@article{arxiv.1506.02604,
  title  = {Performance of a Tungsten-Cerium Fluoride Sampling Calorimeter in High-Energy Electron Beam Tests},
  author = {R. Becker and L. Bianchini and G. Dissertori and L. Djambazov and M. Donegà and W. Lustermann and A. C. Marini and F. Nessi-Tedaldi and F. Pandolfi and M. Peruzzi and M. Schönenberger and F. Cavallari and I. Dafinei and M. Diemoz and C. Jorda Lope and P. Meridiani and M. Nuccetelli and R. Paramatti and F. Pellegrino and F. Micheli and G. Organtini and S. Rahatlou and L. Soffi and L. Brianza and P. Govoni and A. Martelli and T. Tabarelli de Fatis and V. Monti and N. Pastrone and P. P. Trapani and V. Candelise and G. Della Ricca},
  journal= {arXiv preprint arXiv:1506.02604},
  year   = {2015}
}

备注

6 pages, 6 figures, Submitted to NIM A