相关论文: The Development and Study of High-Position Resolut…
The latest HV-CMOS pixel sensor developed by the former CERN-RD50-CMOS group, known as the \mpw, demonstrates competitive radiation tolerance, spatial granularity, and timing resolution -- key requirements for future high-energy physics…
Digital signal processing techniques were employed to investigate the joint use of charge division and risetime analyses for the resistive anode (RA) coupled to a microchannel plate detector (MCP). In contrast to the typical approach of…
For precise start time determination a Beam Fragmentation T$_0$ Counter (BFTC) is under development for the Time-of-Flight Wall of the Compressed Baryonic Matter Spectrometer (CBM) at the Facility for Antiproton and Ion Research (FAIR) at…
Muography is finding applications in various domains such as volcanology, archaeology, civil engineering, industry, mining, and nuclear waste surveys. To simplify transportation and installation in remote locations after laboratory testing,…
A prototype of a position sensitive photo-detector with 5.6 x 5.6 cm2 detection area readout with 64 Hamamatsu MPPCs (S10931-100P) with 3 x 3 mm2 active area each has been built and tested. The photo-sensors are arranged in a 8 x 8 array…
The low cost and high resolution Multi-gap Resistive Plate Chamber (MRPC) opens up a new possibility to find an efficient alternative detector for the Time of Flight (TOF) based Positron Emission Tomography, where the sensitivity of the…
In this study we report the results of a systematic study of the gain, rate and the position resolution limits of various micropattern gaseous detectors. It was found that at low rates (<1 Hz/mm^2) each detector has it own gain limit, which…
During Phase-2 of the LHC, known as the High Luminosity LHC (HL-LHC), the accelerator will increase its instantaneous luminosity to 5 $\times$ 10$^{34}$ cm$^{-2}$ s$^{-1}$, delivering an integrated luminosity of 3000 fb$^{-1}$ over 10 years…
The potential of photon detectors to achieve precise timing information is of increasing importance in many domains, PET and CT scanners in medical imaging and particle physics detectors, amongst others. The goal to increase by an order of…
A Multi-gap Resistive Plate Chamber (MRPC) equipped with heaters to improve the counting rate capability was designed for the BM@N experiment in Dubna. The measurements were performed using a muon beam at IHEP U-70 accelerator in Protvino.…
New developments in Thin Gap Chambers (TGC) detectors to provide fast trigger and high precision muon tracking under sLHC conditions are presented. The modified detectors are shown to stand a high total irradiation dose equivalent to 6…
Position resolution is a key property of the innermost layer of the upgraded ATLAS and CMS pixel detectors for determining track reconstruction and flavor tagging performance. The 11 GeV electron beam at the SLAC End Station A was used to…
CMOS Monolithic Active Pixel Sensors (CPS) are ultra-light and highly granular silicon pixel detectors suited for highly sensitive charged particle tracking. Being manufactured with cost efficient standard CMOS processes, CPS may integrate…
Micro-TPC, a time projection chamber(TPC) with micro pixel chamber($\mu$-PIC) readout was developed for the detection of the three-dimensional fine(sub-m illimeter) tracks of charged particles. We developed a two-dimensional position…
A photon-number-resolving detector based on a four-element superconducting nanowire single photon detector is demonstrated to have sub-30-ps resolution in measuring the arrival time of individual photons. This detector can be used to…
Nowadays RPCs are in a booming phase: they are successfully used in many experiments, including LHC; there are ambitious plans to use them in several upgrade detectors and in some new experiments as well as in various applications. The aim…
The radiation hardness of passive CMOS pixel sensors fabricated in 150 nm LFoundry technology is investigated. CMOS process lines are especially of interest for large-scale silicon detectors as they offer high production throughput at…
A MHz frame rate X-ray area detector (LPD - Large Pixel Detector) is under development by the Rutherford Appleton Laboratory for the European XFEL. The detector will have 1 million pixels and allows analogue storage of 512 images taken at…
A strip-readout parallel-plate avalanche counter (SR-PPAC) has been developed aiming at the high detection efficiency and good position resolution in high-intensity heavy-ion measurements. The performance was evaluated using 115 MeV/u…
We have developed a position response calibration method for a micro-channel plate (MCP) detector with a delay-line anode position readout scheme. Using an {\em in situ} calibration mask, an accuracy of 8~$\mu$m and a resolution of…