相关论文: The Development and Study of High-Position Resolut…
The paper summarizes our latest progress in the development of newly introduced micro pattern gaseous detectors with resistive electrodes. These resistive electrodes protect the detector and the front-end electronics in case of occasional…
We developed a new front-end application specific integrated circuit (ASIC) for the upgrade of the Maia x-ray microprobe. The ASIC instruments 32 configurable front-end channels that perform either positive or negative charge amplification,…
We present recent results of an extensive aging test, performed at the CERN Gamma Irradiation Facility on two single--gap RPC prototypes, developed for the LHCb Muon System. With a method based on a model describing the behaviour of an RPC…
Developed right at the beginning of the space age in the 1940s, the proportional counter was the first detector used in X-ray astronomy and stayed its workhorse for almost four decades. Although the principle of such a detector seems to be…
We report on a new technique of a Multi-Cathode Counter (MCC) developed to search for hidden photon (HP) cold dark matter (CDM) with a mass from 5 to 500 eV. The method suggested in the assumption that hidden photons of the mass greater…
The Time Projection Chamber (TPC) for the International Linear Collider will need to measure about 200 track points with a resolution close to 100 $\mu$m. A Micro Pattern Gas Detector (MPGD) readout TPC could achieve the desired resolution…
A new type of resistive plate chamber with thin-film electrodes based on diamond-like carbon is under development for background identification in the MEG II experiment. Installed in a low-momentum and high-intensity muon beam, the detector…
This note describes a study on the momentum resolution of the TPC-based central tracker design which will be included in the ECFA/DESY conceptual design report (CDR) for the proposed DESY 500 GeV electron-positron linear collider. The study…
The phase-out of hydro-fluorocarbons, owing to their high Global Warming Power, affecting the main gas used in Resistive Plate Chambers (RPCs), tetrafluoroethane C$_2$H$_2$F$_4$, has increased operational difficulties on existing systems…
The POSiCS camera is a handheld, small field-of-view gamma camera developed for multipurpose use in radio-guided surgery (RGS), with sentinel lymph node biopsy (SLNB) as its benchmark application. This compact and lightweight detector…
This paper reports the latest developmental efforts for a position-sensitive glass-based Resistive Plate Chamber (RPC) and a multi-channel Data AcQuisition (DAQ) system tailored for muon tracking in muography applications. The designed…
Photon-number-resolving (PNR) detectors are a key enabling technology in photonic quantum information processing. Here, we demonstrate the PNR capacity of conventional superconducting nanowire single-photon detectors by performing…
Efficiently distinguishing photon numbers is a crucial yet challenging technology for various quantum information and quantum metrology applications. While superconducting transition edge sensors offer good photon-number-resolving (PNR)…
The resolution limits of classical spectroscopy can be surpassed by quantum-inspired methods leveraging the information contained in the phase of the complex electromagnetic field. Their counterpart in spatial imaging has been widely…
Muography (or muon radiography) is an imaging technique that relies on the use of cosmogenic muons as a free and safe radiation source. It can be applied in various fields such as archaeology, civil engineering, geology, nuclear reactor…
I discuss the status of MCP-based photo-detector amplification sections and Cherenkov light sources for precise timing measurements of charged particles and gamma rays. Sub-psec resolution is predicted for the large pulses such as those…
The development of Hybrid CMOS Detectors (HCDs) for X-Ray telescope focal planes will place them in con- tention with CCDs on future satellite missions due to their faster frame rates, flexible readout scenarios, lower power consumption,…
Optimization of spacer and gas distribution inside glass resistive plate chamber (RPC) is reported. Simulation studies demonstrate improvements on the gas flow velocity homogeneity and lower vorticity inside the gas chamber. The optimized…
Photon number resolving (PNR) measurements are beneficial or even necessary for many applications in quantum optics. Unfortunately, PNR detectors are usually large, slow, expensive, and difficult to operate. However, if the input signal is…
We have developed a position-sensitive scintillation camera with a large area absorber for use as an advanced Compton gamma-ray camera. At first we tested GSO(Ce) crystals. We compared light output from the GSO(Ce) crystals under various…