相关论文: Triple GEM operation in compressed He and Kr
At present, part of the forward RPC muon system of the CMS detector at the CERN LHC remains uninstrumented in the high-\eta region. An international collaboration is investigating the possibility of covering the 1.6 < |\eta| < 2.4 region of…
The idea of implementing electroluminescence-based amplification through transparent multi-hole structures (FAT-GEMs) has been entertained for some time. Arguably, for such a technology to be attractive it should perform at least at a level…
We present new measurements of the energy spectra of cosmic-ray (CR) nuclei from the second flight of the balloon-borne experiment Cosmic Ray Energetics And Mass (CREAM). The instrument included different particle detectors to provide…
Gaseous PhotoMultipliers (GPM) are a very promising alternative of vacuum PMTs especially for large-size noble-liquid detectors in the field of Functional Nuclear Medical Imaging and Direct Dark Matter Detection. We present recent…
The Gas Electron Multiplier (GEM) foil is an amplification stage that has been introduced to overcome the problem of discharges observed in gaseous detectors. There are two major production techniques of GEM foils: double-mask and…
Many experiments are currently using or proposing to use large area GEM foils in their detectors, which is creating a need for commercially available GEM foils. Currently CERN is the only main distributor of large GEM foils, however with…
Although they are rare elements in the Earth's mantle, noble gases (NG) owe to their strongly varying masses contrasting physical behaviors making them important geochemical tracers. When partial melting occurs at depth, the partitioning of…
A database of DIII-D plasmas without ELMs compares the operating space and plasma performance of stationary no-ELM regimes: RMP-ELM suppression, QH-mode, I-mode, EDA H-mode, L-mode, and negative triangularity L-mode (Neg-D). Operational…
The CYGNO experiment aims to build a large ($\mathcal{O}(10)$ m$^3$) directional detector for rare event searches, such as nuclear recoils (NRs) induced by dark matter (DM), such as weakly interactive massive particles (WIMPs). The detector…
The new beam profile measurement for the Antiproton Decelerator (AD) at CERN is based on a single Gas Electron Multiplier (GEM) with a 2D readout structure. This detector is very light, ~0.4% X0, as required by the low energy of the…
We report on the properties of thick GEM-like (THGEM) electron multipliers made of 0.4 mm thick double-sided Cu-clad G-10 plates, perforated with a dense hexagonal array of 0.3 mm diameter drilled holes. Photon detectors comprising THGEMs…
We present net gain measurements at room temperature in Al$_{0.07}$Ga$_{0.93}$N/GaN 10-period multi-quantum well emitting at 367 nm, using the variable stripe length method. Measurements were conducted at two different positions on the…
The performance and long term stability of an optically readout Time Projection Chamber with an electron amplification structure based on three Gas Electron Multipliers was studied. He/CF$_4$ based gas mixtures were used in two different…
A new observation is presented that the densities and temperatures at the critical and triple points ($n_{cr}$, $n_{tp}$, $T_{cr}$, and $T_{tp}$) of neon, argon, krypton, and xenon are such that $T_{cr}/T_{tp}=1.803\pm 0.5\%$ and…
Low pressure gaseous Time Projection Chambers (TPCs) are a viable technology for directional Dark Matter (DM) searches and have the potential for exploring the parameter space below the neutrino fog. Gases like CF4 are advantageous because…
The performance of a two-phase Ar avalanche detector in a single electron counting mode was studied, with regard to potential application in coherent neutrino-nucleus scattering and dark matter search experiments. The detector comprised of…
We present the results of the operation of an array of avalanche photodiodes (APDs) for the readout of an electroluminescence detector. The detector contains 24 APDs with a pitch of 15 mm between them allowing energy and position…
The construction of a micro-pattern gas detector of dimensions 40x10 cm**2 is described. Two gas electron multiplier foils (GEM) provide the internal amplification stages. A two-layer readout structure was used, manufactured in the same…
Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the $1.5 < \mid\eta\mid < 2.2$ region of…
Working gas components significantly impact the performance of gaseous detectors. A fast-timing Micromegas detector with two-stage amplification is prone to notable deterioration of uniformity when scaled up. This paper presents a…