中文
相关论文

相关论文: Radio-frequency impedance measurements using a tun…

200 篇论文

A vertical resonant tunneling diode (RTD) based on the paramagnetic Zn1-x-yMnyCdxSe system has been fabricated with a pillar diameter down to ~ 6 micron. The diode exhibits high quality resonant tunneling characteristics through the…

介观与纳米尺度物理 · 物理学 2009-11-13 Z. L. Fang , P. Wu , N. Kundtz , A. M. Chang , X. Y. Liu , J. K. Furdyna

For TOF positron emission tomography (TOF PET) detectors, time-to-digital converters (TDCs) are essential to resolve the coincidence time of the photon pairs. Recently, an efficient TDC structure called ring-oscillator-based (RO-based)…

仪器与探测器 · 物理学 2017-06-12 Ke Cui , Xiangyu Li , Zongkai Liu , Rihong Zhu

The traditional transmission coefficient present in the original Landauer formulation, which is valid for quasi-static scenarios with working frequencies below the inverse of the electron transit time, is substituted by a novel…

介观与纳米尺度物理 · 物理学 2021-03-24 Matteo Villani , Simone Clochiatti , Werner Prost , Nils Weimann , Xavier Oriols

Time-reversal symmetry breaking (TRSB) has been central to detecting exotic phases of matter. Here, we leverage the circuit electrodynamics capabilities of superconducting devices to propose a novel scheme based on a multimode…

Strong nonlinearity of a self-resonant radio frequency superconducting quantum interference device (rf-SQUID) meta-atom is explored via intermodulation (IM) measurements. Previous work in zero dc magnetic flux showed a sharp onset of IM…

We demonstrate a highly sensitive real-time magnetometry method at two measurement points. This magnetometry method is based on the frequency-division multiplexing of continuous-wave optically detected magnetic resonance. We use two…

Despite the high measurement fidelity that can now be reached, the dispersive qubit readout of circuit quantum electrodynamics is plagued by a loss of its quantum nondemolition character and a decrease in fidelity with increased measurement…

We report the bias voltage controlled inversions of tunneling magnetoresistance (TMR) in magnetic tunnel junctions composed of Fe3GaTe2 electrodes and hBN tunneling barrier, observed at room temperature. The polarity reversal of TMR occurs…

介观与纳米尺度物理 · 物理学 2025-01-13 Lihao Zhang , Miao He , Xiaoyu Wang , Haodong Zhang , Keying Han , Yonglai Liu , Lei Zhang , Yingchun Cheng , Jie Pan , Zhe Qu , Zhe Wang

Impedance measurements provide a useful probe of the physics of bolometers and calorimeters. We describe a method for measuring the complex impedance of these devices. In previous work, stray impedances and readout electronics of the…

We have developed a transient thermoreflectance technique using picosecond pulsed and cw laser to study thermal conductivity and interface conductance in both thin-films and bulk materials. A real time-resolved system observes a thermal…

The article explores the ion flux response of a capacitor configuration to an alternating voltage. The model system comprises a symmetric binary electrolyte confined between plan-parallel capacitor plates. The AC response is investigated…

化学物理 · 物理学 2018-10-03 Sonja Babel , Michael Eikerling , Hartmut Löwen

Capacitance measurements are crucial for probing the electrical properties of materials. In this study, we develop and implement a capacitance measurement technique optimized for pulsed magnetic fields. Our approach employs an…

Radio frequency magneto-impedance measurements clearly reveal a pronounced anomaly at 260K besides the main MI transition at 125K in the double perovskite material $La_{1.2}Sr_{1.8}Mn_{2}O_{7}$. This feature is not seen clearly in static…

Impedance measurement is a common technique to characterize and detect the electrical properties of biological cells. However, to decode the underlying physical processes, it requires complex electrical models alongside prior knowledge of…

We report on magneto-oscillations in differential resistivity of a two-dimensional electron system subject to intense microwave radiation. The period of these oscillations is determined not only by microwave frequency but also by its…

介观与纳米尺度物理 · 物理学 2010-05-31 M. Khodas , H. -S. Chiang , A. T. Hatke , M. A. Zudov , M. G. Vavilov , L. N. Pfeiffer , K. W. West

Nonlinear magnetotransport of a microwave-irradiated high mobility two-dimensional electron system under a finite direct current excitation is analyzed using a dc-controlled scheme with photon-assisted transition mechanism. The predicted…

介观与纳米尺度物理 · 物理学 2008-08-27 X. L. Lei , S. Y. Liu

Dynamic properties of NiFe thin films on PMN-PT piezoelectric substrate are investigated using the spin-diode method. Ferromagnetic resonance (FMR) spectra of microstrips with varying width are measured as a function of magnetic field and…

We report on the first measurement of the Seebeck coefficient in a tunnel-contacted and gate-tunable individual single-quantum dot junction in the Kondo regime, fabricated using the electromigration technique. This fundamental…

介观与纳米尺度物理 · 物理学 2019-01-31 B. Dutta , D. Majidi , A. Garcia Corral , P. Erdman , S. Florens , T. Costi , H. Courtois , C. B. Winkelmann

A cavity optomechanical magnetometer is demonstrated where the magnetic field induced expansion of a magnetostrictive material is transduced onto the physical structure of a highly compliant optical microresonator. The resulting motion is…

Levitated ferromagnetic systems are expected to have significant potential in precision magnetic field sensing by leveraging mechanical isolation to minimize mechanical contact and associated noise. Here, we report the implementation of a…

量子物理 · 物理学 2026-03-03 Ren Yichong , Wu Lielie , Broer Wijnand , Xue Fei , Huang Pu , Du JiangFeng