中文
相关论文

相关论文: Self-Supervised Angular Deblurring in Photoacousti…

200 篇论文

In this article, we are concerned with a nonlinear inverse problem with a forward operator involving an unknown function. The problem arises in diverse applications and is challenging in the presence of an unknown function, which makes it…

数值分析 · 数学 2023-02-07 Gyeongha Hwang , Gihyeon Jeon , Sunghwan Moon

Image denoising is a prerequisite for downstream tasks in many fields. Low-dose and photon-counting computed tomography (CT) denoising can optimize diagnostic performance at minimized radiation dose. Supervised deep denoising methods are…

机器学习 · 计算机科学 2022-01-06 Chuang Niu , Mengzhou Li , Fenglei Fan , Weiwen Wu , Xiaodong Guo , Qing Lyu , Ge Wang

Photoacoustic computed tomography (PACT) is a non-invasive imaging modality, similar to ultrasound, with wide-ranging medical applications. Conventional PACT images are degraded by wavefront distortion caused by the heterogeneous speed of…

图像与视频处理 · 电气工程与系统科学 2025-08-05 Tianao Li , Manxiu Cui , Cheng Ma , Emma Alexander

Sparse-view computed tomography (CT) enables fast and low-dose CT imaging, an essential feature for patient-save medical imaging and rapid non-destructive testing. In sparse-view CT, only a few projection views are acquired, causing…

图像与视频处理 · 电气工程与系统科学 2024-02-28 Nadja Gruber , Johannes Schwab , Elke Gizewski , Markus Haltmeier

Limited-Angle Computed Tomography (LACT) is a challenging inverse problem where missing angular projections lead to incomplete sinograms and severe artifacts in the reconstructed images. While recent learning-based methods have demonstrated…

图像与视频处理 · 电气工程与系统科学 2025-07-09 Jiaqi Guo , Santiago López-Tapia

Self-supervised image denoising methods have traditionally relied on either architectural constraints or specialized loss functions that require prior knowledge of the noise distribution to avoid the trivial identity mapping. Among these,…

图像与视频处理 · 电气工程与系统科学 2026-03-30 Brayan Monroy , Jorge Bacca , Julián Tachella

Photoacoustic computed tomography (PACT) is an emerging computed imaging modality that exploits optical contrast and ultrasonic detection principles to form images of the absorbed optical energy density within tissue. When the imaging…

医学物理 · 物理学 2016-11-15 Qiwei Sheng , Kun Wang , Thomas P. Matthews , Jun Xia , Liren Zhu , Lihong V. Wang , Mark A. Anastasio

Photoacoustic tomography (PAT) enables non-invasive cross-sectional imaging of biological tissues, but it fails to map the spatial variation of speed-of-sound (SOS) within tissues. While SOS is intimately linked to density and elastic…

医学物理 · 物理学 2024-08-27 Yang Wang , Danni Wang , Liting Zhong , Yi Zhou , Qing Wang , Wufan Chen , Li Qi

Current 3D photoacoustic tomography (PAT) systems offer either high image quality or high frame rates but are not able to deliver high spatial and temporal resolution simultaneously, which limits their ability to image dynamic processes in…

Photoacoustic tomography (PAT) is an emerging imaging modality that aims at measuring the high-contrast optical properties of tissues by means of high-resolution ultrasonic measurements. The interaction between these two types of waves is…

偏微分方程分析 · 数学 2021-07-27 Giovanni S. Alberti , Paolo Campodonico , Matteo Santacesaria

We discuss several methods for image reconstruction in compressed sensing photoacoustic tomography (CS-PAT). In particular, we apply the deep learning method of [H. Li, J. Schwab, S. Antholzer, and M. Haltmeier. NETT: Solving Inverse…

Photoacoustic (PA) computed tomography (PACT) shows great potentials in various preclinical and clinical applications. A great number of measurements are the premise that obtains a high-quality image, which implies a low imaging rate or a…

计算机视觉与模式识别 · 计算机科学 2021-06-01 Hengrong Lan , Juze Zhang , Changchun Yang , Fei Gao

When taking photos under an environment with insufficient light, the exposure time and the sensor gain usually require to be carefully chosen to obtain images with satisfying visual quality. For example, the images with high ISO usually…

计算机视觉与模式识别 · 计算机科学 2022-11-15 Zhilu Zhang , Rongjian Xu , Ming Liu , Zifei Yan , Wangmeng Zuo

Photoacoustic imaging is an emerging imaging modality that is based upon the photoacoustic effect. In photoacoustic tomography (PAT), the induced acoustic pressure waves are measured by an array of detectors and used to reconstruct an image…

计算机视觉与模式识别 · 计算机科学 2019-04-26 Steven Guan , Amir Khan , Siddhartha Sikdar , Parag V. Chitnis

Among all tissue imaging modalities, photo-acoustic tomography (PAT) has been getting increasing attention in the recent past due to the fact that it has high contrast, high penetrability, and has capability of retrieving high resolution.…

图像与视频处理 · 电气工程与系统科学 2021-05-20 Nadaparambil Aravindakshan Rejesh , Muthuvel Arigovindan

Photoacoustic tomography (PAT) is a hybrid medical imaging technique that offer high contrast and a high spatial resolution. One challenging mathematical problem associated with PAT is reconstructing the initial pressure of the wave…

数值分析 · 数学 2024-07-16 Gyeongha Hwang , Gihyeon Jeon , Sunghwan Moon , Dabin Park

In this work, we present a novel self-supervised method for Low Dose Computed Tomography (LDCT) reconstruction. Reducing the radiation dose to patients during a CT scan is a crucial challenge since the quality of the reconstruction highly…

图像与视频处理 · 电气工程与系统科学 2023-12-21 Hang Xu , Alessandro Perelli

Dual-energy computed tomography (DECT) has shown great potential and promising applications in advanced imaging fields for its capabilities of material decomposition. However, image reconstructions and decompositions under sparse views…

医学物理 · 物理学 2016-08-01 Lei Li , Ailong Cai , Linyuan Wang , Bin Yan , Hanming Zhang , Zhizhong Zheng , Wenkun Zhang , Wanli Lu , Guoen Hu

Photoacoustic tomography (PAT) is a newly emerged imaging modality which enables both high optical contrast and acoustic depth of penetration. Reconstructing images of photoacoustic tomography from limited amount of senser data is among one…

计算机视觉与模式识别 · 计算机科学 2023-06-27 Shangqing Tong , Hengrong Lan , Liming Nie , Jianwen Luo , Fei Gao

Curvelet frame is of special significance for photoacoustic tomography (PAT) due to its sparsifying and microlocalisation properties. We derive a one-to-one map between wavefront directions in image and data spaces in PAT which suggests…

计算机视觉与模式识别 · 计算机科学 2021-08-09 Bolin Pan , Simon R. Arridge , Felix Lucka , Ben T. Cox , Nam Huynh , Paul C. Beard , Edward Z. Zhang , Marta M. Betcke