中文
相关论文

相关论文: Diffusion Model Regularized Implicit Neural Repres…

200 篇论文

Metal artifacts in computed tomography (CT) images can significantly degrade image quality and impede accurate diagnosis. Supervised metal artifact reduction (MAR) methods, trained using simulated datasets, often struggle to perform well on…

图像与视频处理 · 电气工程与系统科学 2025-01-28 Chenglong Ma , Zilong Li , Yuanlin Li , Jing Han , Junping Zhang , Yi Zhang , Jiannan Liu , Hongming Shan

Computed tomography (CT) is an imaging modality widely used for medical diagnosis and treatment. CT images are often corrupted by undesirable artifacts when metallic implants are carried by patients, which creates the problem of metal…

图像与视频处理 · 电气工程与系统科学 2019-07-02 Wei-An Lin , Haofu Liao , Cheng Peng , Xiaohang Sun , Jingdan Zhang , Jiebo Luo , Rama Chellappa , Shaohua Kevin Zhou

For the task of metal artifact reduction (MAR), although deep learning (DL)-based methods have achieved promising performances, most of them suffer from two problems: 1) the CT imaging geometry constraint is not fully embedded into the…

图像与视频处理 · 电气工程与系统科学 2021-09-14 Hong Wang , Yuexiang Li , Haimiao Zhang , Jiawei Chen , Kai Ma , Deyu Meng , Yefeng Zheng

Metal artifacts in Dental CBCT severely obscure anatomical structures, hindering diagnosis. Current deep learning for Metal Artifact Reduction (MAR) faces limitations: supervised methods suffer from spectral blurring due to…

计算机视觉与模式识别 · 计算机科学 2026-01-05 Zhi Li , Yaqi Wang , Bingtao Ma , Yifan Zhang , Huiyu Zhou , Shuai Wang

Metal implants can heavily attenuate X-rays in computed tomography (CT) scans, leading to severe artifacts in reconstructed images, which significantly jeopardize image quality and negatively impact subsequent diagnoses and treatment…

医学物理 · 物理学 2021-08-11 Tao Wang , Wenjun Xia , Yongqiang Huang , Huaiqiang Sun , Yan Liu , Hu Chen , Jiliu Zhou , Yi Zhang

Implicit Neural Representations (INRs) are a learning-based approach to accelerate Magnetic Resonance Imaging (MRI) acquisitions, particularly in scan-specific settings when only data from the under-sampled scan itself are available.…

图像与视频处理 · 电气工程与系统科学 2024-12-11 Yamin Arefeen , Brett Levac , Zach Stoebner , Jonathan Tamir

Artifacts pose a significant challenge in medical imaging, impacting diagnostic accuracy and downstream analysis. While image-based approaches for detecting artifacts can be effective, they often rely on preprocessing methods that can lead…

图像与视频处理 · 电气工程与系统科学 2025-08-08 Caner Özer , Patryk Rygiel , Bram de Wilde , İlkay Öksüz , Jelmer M. Wolterink

Since the invention of modern CT systems, metal artifacts have been a persistent problem. Due to increased scattering, amplified noise, and insufficient data collection, it is more difficult to suppress metal artifacts in cone-beam CT,…

医学物理 · 物理学 2023-10-27 Tianling Lyu , Zhan Wu , Gege Ma , Chen Jiang , Xinyun Zhong , Yan Xi , Yang Chen , Wentao Zhu

Computed tomography (CT) metal artifact reduction (MAR) aims to reduce the severe streaking artifacts induced by metallic implants and other high-density objects. Effective MAR generally requires both accurate artifact localization and…

计算机视觉与模式识别 · 计算机科学 2026-05-19 Zilong Li , Chenglong Ma , Yiming Lei , Yuanlin Li , Jing Han , Jiannan Liu , Huidong Xie , Junping Zhang , Yi Zhang , Hongming Shan

Recent deep learning-based methods have achieved promising performance for computed tomography metal artifact reduction (CTMAR). However, most of them suffer from two limitations: (i) the domain knowledge is not fully embedded into the…

网络与互联网体系结构 · 计算机科学 2022-11-15 Baoshun Shi , Ke Jiang , Shaolei Zhang , Qiusheng Lian , Yanwei Qin

Magnetic Resonance Imaging generally requires long exposure times, while being sensitive to patient motion, resulting in artifacts in the acquired images, which may hinder their diagnostic relevance. Despite research efforts to decrease the…

图像与视频处理 · 电气工程与系统科学 2025-02-04 Paolo Angella , Vito Paolo Pastore , Matteo Santacesaria

Although sparse-view computed tomography (CT) has significantly reduced radiation dose, it also introduces severe artifacts which degrade the image quality. In recent years, deep learning-based methods for inverse problems have made…

图像与视频处理 · 电气工程与系统科学 2024-01-02 Shuo Xu , Yucheng Zhang , Gang Chen , Xincheng Xiang , Peng Cong , Yuewen Sun

Computed tomography (CT) involves a patient's exposure to ionizing radiation. To reduce the radiation dose, we can either lower the X-ray photon count or down-sample projection views. However, either of the ways often compromises image…

图像与视频处理 · 电气工程与系统科学 2023-10-12 Wenjun Xia , Yongyi Shi , Chuang Niu , Wenxiang Cong , Ge Wang

Metal artifact correction is a challenging problem in cone beam computed tomography (CBCT) scanning. Metal implants inserted into the anatomy cause severe artifacts in reconstructed images. Widely used inpainting-based metal artifact…

图像与视频处理 · 电气工程与系统科学 2023-10-10 Harshit Agrawal , Ari Hietanen , Simo Särkkä

Cone Beam Computed Tomography (CBCT) plays a key role in dental diagnosis and surgery. However, the metal teeth implants could bring annoying metal artifacts during the CBCT imaging process, interfering diagnosis and downstream processing…

图像与视频处理 · 电气工程与系统科学 2024-04-19 Yuxuan Shi , Jun Xu , Dinggang Shen

High-quality imaging in photoacoustic computed tomography (PACT) usually requires a high-channel count system for dense spatial sampling around the object to avoid aliasing-related artefacts. To reduce system complexity, various image…

图像与视频处理 · 电气工程与系统科学 2024-09-24 Bowei Yao , Shilong Cui , Haizhao Dai , Qing Wu , Youshen Xiao , Fei Gao , Jingyi Yu , Yuyao Zhang , Xiran Cai

Metallic implants introduce severe artifacts in CT images, which degrades the image quality. It is an effective method to reduce metal artifacts by replacing the metal affected projection with the forward projection of a prior image. How to…

医学物理 · 物理学 2014-09-05 Yanbo Zhang , Xuanqian Mou

Metal artifacts caused by the presence of metallic implants tremendously degrade the reconstructed computed tomography (CT) image quality, affecting clinical diagnosis or reducing the accuracy of organ delineation and dose calculation in…

The reduction of metal artifacts in computed tomography (CT) images, specifically for strong artifacts generated from multiple metal objects, is a challenging issue in medical imaging research. Although there have been some studies on…

图像与视频处理 · 电气工程与系统科学 2020-08-24 Megumi Nakao , Keiho Imanishi , Nobuhiro Ueda , Yuichiro Imai , Tadaaki Kirita , Tetsuya Matsuda

The presence of metal implants within CT imaging causes severe attenuation of the X-ray beam. Due to the incomplete information recorded by CT detectors, artifacts in the form of streaks and dark bands would appear in the resulting CT…