相关论文: A cryogenic test-mass suspension with flexures ope…
Thermal noise from the suspension fibres used in the mirror pendulums in current gravitational wave detectors is a critical noise source. Future detectors will require improved suspension performance with the specific ability to suspend…
We report the mirror suspension design for Large-scale Cryogenic Gravitational wave Telescope, KAGRA, during bKAGRA Phase 1. Mirror thermal noise is one of the fundamental noises for room-temperature gravitational-wave detectors such as…
We present the design and commissioning of a cryogenic low-vibration test facility that measures displacement noise from a gram-scale silicon cantilever at the level of 10$^{-16}\, \mathrm{m/\sqrt{Hz}}$ at 1kHz. A volume of $\sim$36 litres…
The next generation of gravitational-wave detectors, such as the Einstein Telescope, is designed to reduce noise in a wide band of frequencies compared to the current generation, through the use of new technologies. ETpathfinder, designed…
The use of fused-silica ribbons as suspensions in gravitational wave interferometers can result in significant improvements in pendulum mode thermal noise. Surface loss sets a lower bound to the level of noise achievable, at what level…
The suspension noise in interferometric gravitational wave detectors is caused by losses at the top and the bottom attachments of each suspension fiber. We use the Fluctuation-Dissipation theorem to argue that by careful positioning of the…
Recent observations made with Advanced LIGO and Advanced Virgo have initiated the era of gravitational-wave astronomy. The number of events detected by these "2nd Generation" (2G) ground-based observatories is partially limited by noise…
Spring-antispring systems have been investigated as possible low-frequency seismic isolation in high-precision optical experiments. These systems provide the possibility to tune the fundamental resonance frequency to, in principle,…
The thermal noise is expected to be one of the main limiting factors on the sensitivity of interferometric gravitational-wave detectors like LIGO and VIRGO. Thermal fluctuations of internal modes of the interferometer's test masses and of…
Pulse-tube based dilution refrigerators are massively employed in low temperature physics. They allow to reduce the running costs and to be operated with unprecedented easiness. However, the main drawback of this technology is the…
A system providing an optical frequency with an instability comparable to that of a hydrogen maser is presented. It consists of a $5$ $\mathrm{cm}$ long, vertically oriented silicon optical resonator operated at temperatures between $1.5$…
Next-generation gravitational wave observatories are expected to use cryogenically cooled, pendulum-suspended 200 kg test mass mirrors from a crystalline material such as crystalline silicon. During operation of the observatories, these…
We describe a liquid-cryogen free cryostat with ultra-low vibration levels which allows for continuous operation of a torsion balance at cryogenic temperatures. The apparatus uses a commercially available two-stage pulse-tube cooler and…
The Einstein Telescope (ET) is a third generation gravitational wave detector that includes a room-temperature high-frequency (ET-HF) and a cryogenic low-frequency laser interferometer (ET-LF). The cryogenic ET-LF is crucial for exploiting…
Crystalline silicon has been proposed as a new test mass material in third generation gravitational wave detectors such as the Einstein Telescope (ET). Birefringence can reduce the interferometric contrast and can produce dynamical…
The thermal fluctuation of mirror surfaces is the fundamental limitation for interferometric gravitational wave (GW) detectors. Here, we experimentally demonstrate for the first time a reduction in a mirror's thermal fluctuation in a GW…
We present the design, control system, and noise analysis of a 6-axis seismometer comprising a mass suspended by a single fused silica fibre. We utilise custom-made, compact Michelson interferometers for the readout of the mass motion…
The sensitivity of future gravitational wave (GW) observatories will be limited by thermal noise in a wide frequency band. To reduce thermal noise, the European GW observatory Einstein GW Telescope (ET) is suggested to use crystalline…
Future gravitational wave detectors (GWDs) such as Advanced LIGO upgrades and the Einstein Telescope are planned to operate at cryogenic temperatures using crystalline silicon (cSi) test-mass mirrors at an operation wavelength of 1550 nm.…
We report on the cryogenic properties of a low-contraction silicon-aluminum composite, namely Japan Fine Ceramics SA001, to use as a packaging structure for cryogenic silicon devices. SA001 is a silicon--aluminum composite material (75%…