相关论文: Characterisation of SiC radiation detector technol…
A MHz frame rate X-ray area detector (LPD - Large Pixel Detector) is under development by the Rutherford Appleton Laboratory for the European XFEL. The detector will have 1 million pixels and allows analogue storage of 512 images taken at…
Muon scattering tomography is a non-destructive technique used to image different materials by utilizing natural cosmic ray muons. Typically it requires position-sensitive detectors with a sub-millimeter resolution to effectively…
High-granularity homogeneous electromagnetic calorimeters based on scintillating crystals and silicon photomultipliers (SiPMs) are a promising option for future $e^{+}e^{-}$ Higgs factories, where both excellent energy resolution and a very…
Strip and pixels sensors, fabricated on high resistivity silicon substrate, normally of p-type, are used in detectors for High Energy Physics (HEP) typically in a hybrid detector assembly. Furthermore, and owing to their inherent advantages…
While designed primarily for X-ray imaging applications, the Medipix3 ASIC can also be used for charged-particle tracking. In this work, results from a beam test at the CERN SPS with irradiated and non-irradiated sensors are presented and…
Color-center defects in silicon carbide promise opto-electronic quantum applications in several fields, such as computing, sensing and communication. In order to scale down and combine these functionalities with the existing silicon device…
A double-layer silicon detector consisting of two 500micron-thick silicon PIN photodiodes with independent readouts was mounted in a vacuum chamber and tested with X-ray sources. The detector is sensitive from 1-30 keV with an effective…
The demonstration of universal quantum logic operations near the fault-tolerance threshold establishes ion-implanted near-surface donor atoms as a plausible platform for scalable quantum computing in silicon. The next technological step…
Silicon strip sensors have long been a reliable technology for particle detection. Here, we push the limits of silicon tracking detectors by targeting an unprecedentedly low material budget of 2%-7% $X_0$ in an 8-layer 4 m$^2$ detector…
The Advanced X-ray Imaging Satellite (AXIS) is a NASA probe class mission concept designed to deliver arcsecond resolution with an effective area ten times that of Chandra (at launch). The AXIS focal plane features an MIT Lincoln Laboratory…
Silicon Photomultipliers (SiPMs) are considered as a solid-state sensor alternative to photomultiplier tubes in experiments using liquid xenon (LXe) as a radiation detection medium. The main requirements are single-photon detection of the…
Amorphous silicon carbide (a-SiC) has emerged as a compelling candidate for applications in integrated photonics, known for its high refractive index, high optical quality, high thermo-optic coefficient, and strong third-order…
The planned HL-LHC (High Luminosity LHC) in 2025 is being designed to maximise the physics potential through a sizable increase in the luminosity up to 6*10^34 cm^-2 s^-1. A consequence of this increased luminosity is the expected radiation…
The realization of ultrahigh quality (Q) resonators regardless of the underpinning material platforms has been a ceaseless pursuit, because the high Q resonators provide an extreme environment of storage of light to enable observations of…
Silicon's bandgap inherently restricts its photodetection to wavelengths below 1100 nm, necessitating the integration of costly III-V semiconductors for short-wave infrared applications. Hyperdoping silicon beyond the solid solubility limit…
Silicon-based photosensors (SiPMs) working in the Geiger-mode represent an elegant solution for the readout of particle detectors working at low-light levels like Cherenkov detectors. Especially the insensitivity to magnetic fields makes…
A laser multicharged ion source was used to perform interfacial treatment of the 4H-SiC/ SiO2 interface using B and Ba ions. A Q-switched Nd:YAG laser (wavelength {\lambda} = 1064 nm, pulse width {\tau} = 7 ns, and fluence F = 135 J/cm2)…
The characteristics of a hydrogenated amorphous silicon (a-Si:H) detector are presented here for monitoring in space solar flares and the evolution of large energetic proton events up to hundreds of MeV. The a-Si:H presents an excellent…
A new silicon-strip-type detector was developed for precise charged-particle tracking in the central rapidity region of heavy ion collisions. A new detector and collaboration at the Relativistic Heavy Ion Collider at Brookhaven National…
Compact X-rays detectors made of 1/2" or 1" :LaBr3:Ce crystals of cubic shape with SiPM array readout have been developed for the FAMU experiment at RIKEN-RAL. The aim is a precise measurement of the proton Zemach radius with incoming…