相关论文: Low Radon Concentration Measurement with a Radon-D…
The removal of Radon induced Lead from liquid scintillator was extensively studied in preparation for KamLAND's low background phase. This work presents the results from laboratory experiments performed at the University of Alabama and…
Measuring slow neutrons is difficult when the radiation field also contains charged particles and fast neutrons, especially when the radiation composition is not known in advance. In this work, we present a tested method to measure slow…
RED-100 is a two-phase detector for study of coherent elastic scattering of reactor electron antineutrinos off xenon atomic nuclei. The detector contains a total of 200 kg of liquid xenon in a titanium cryostat with 160 kg of xenon in…
The next generation low-background detectors operating underground aim for unprecedented low levels of radioactive backgrounds. Although the radioactive decays of airborne radon (particularly Rn-222) and its subsequent progeny present in an…
A one-year monitoring study was conducted in a pilot house with high radon levels to investigate the ability and efficiency of radon mitigation by soil depressurisation (SD) both active and passive. The study included monitoring of radon…
Organic liquid scintillators are used in a wide variety of applications in experimental nuclear and particle physics. Boron-loaded scintillators are particularly useful for detecting neutron captures, due to the high thermal neutron capture…
The selection of low-radioactive construction materials is of utmost importance for the success of low-energy rare event search experiments. Besides radioactive contaminants in the bulk, the emanation of radioactive radon atoms from…
The feasibility of an ultra-low energy nuclear-recoil measurement in liquid xenon using neutron capture is investigated for a small (sub-kilogram) liquid xenon detector that is optimized for a high scintillation gain, and a pulsed neutron…
We carried out a study of neutrino detection at the experimental fast reactor JOYO using a 0.76 tons gadolinium loaded liquid scintillator detector. The detector was set up on the ground level at 24.3m from the JOYO reactor core of 140MW…
At high luminosity areas, beam loss monitor with fast response and high radiation resistance is crucial for accelerator operation. In this article, we report the design and test results of a fast response and radiation-resistant…
Liquid xenon detectors such as XENON10 and XENON100 obtain a significant fraction of their sensitivity to light (<10 GeV) particle dark matter by looking for nuclear recoils of only a few keV, just above the detector threshold. Yet in this…
We present a detector apparatus, DireXeno (DIRectinal Xenon), designed to measure the spatial and temporal properties of scintillation in liquid xenon to very high accuracy. The properties of scintillation are of primary importance for dark…
We describe the purification of xenon from traces of the radioactive noble gas radon using a cryogenic distillation column. The distillation column is integrated into the gas purification loop of the XENON100 detector for online radon…
The China Dark Matter Experiment (CDEX) is located at the China Jinping underground laboratory (CJPL) and aims to directly detect the WIMP flux with high sensitivity in the low mass region. Here we present a study of the predicted photon…
The Scintillating Bubble Chamber (SBC) Collaboration is designing a new generation of low background, noble liquid bubble chamber experiments with sub-keV nuclear recoil threshold. These experiments combine the electronic recoil blindness…
Liquid nitrogen is commonly used in cryogenic applications and is a promising medium for the direct immersion cooling of sensors used for nuclear and particle physics experiments. The scintillation properties of gaseous nitrogen are…
Neutrino experiments often use large volumes of water, organic scintillators or noble liquids as active detection material. Due to the large hydrostatic and buoyancy forces involved, precise knowledge of the liquid levels inside the…
The Jiangmen Underground Neutrino Observatory (JUNO), a 20 kton multi-purpose low background liquid scintillator detector, was proposed primarily to determine the neutrino mass ordering. To mitigate radioactivity from surrounding rock and…
We report on the measurements of the fluxes and spectra of the environmental fast neutron background at the China Jinping Underground Laboratory (CJPL) with a rock overburden of about 6700 meters water equivalent, using a liquid…
The Jiangmen Underground Neutrino Observatory(JUNO) is a state-of-the-art liquid scintillator-based neutrino physics experiment under construction in South China. To reduce the background from external radioactivities, a water Cherenkov…