相关论文: Study experimental time resolution limits of recen…
The timing performance of the Timepix4 application-specific integrated circuit (ASIC) bump-bonded to a $100\;\mu\textrm{m}$ thick n-on-p silicon sensor is presented. A picosecond pulsed infrared laser was used to generate electron-hole…
The first generation of Single electron Sensitive Read Out (SiSeRO) amplifiers, employed as on-chip charge detectors for charge-coupled devices (CCDs) have demonstrated excellent noise and spectral performance: a responsivity of around 800…
Significant progress has been made to develop silicon pixel technologies for use in the vertex and tracker regions of the proposed Compact Linear Collider (CLIC) detector design. The electron-positron collisions generated by this linear…
Fourier transform spectroscopy (FTS) has been widely used in a variety of fields in research, industry, and medicine due to its high signal-to-noise ratio, simultaneous acquisition of signals in a broad spectrum, and versatility for…
Positron Annihilation Lifetime Spectroscopy (PALS) is a non-destructive radiological technique widely used in material science studies. PALS typically relies on an analog coincidence measurement setup and allows the estimate of the positron…
The NEXT-White detector, a high-pressure gaseous xenon time projection chamber, demonstrated the excellence of this technology for future neutrinoless double beta decay searches using photomultiplier tubes (PMTs) to measure energy and…
We study the potential of the MCP-PMT read-out to detect single photo-electron using transmission lines. Such a solution limits the number of read-out channels, has a uniform time resolution across the PMT surface and provides…
We present the set-up and test-measurements of a waveguide-integrated heterodyne diagnostic for coherent transition radiation (CTR) in the AWAKE experiment. The goal of the proof-of-principle experiment AWAKE is to accelerate a witness…
Recent clinical evidence shows a correlation between linear energy transfer (LET) and tumor control in carbon ion radiotherapy. This prompts the direct inclusion of LET into the treatment planning. Currently, LET is mainly extracted from…
The high energy physics community has recently identified an $e^+e^-$ Higgs factory as one of the next-generation collider experiments, following the completion of the High Luminosity LHC program at CERN.The moderate radiation levels…
The ABCStar is a mixed-signal front-end readout ASIC for the strips sensor portion of the ATLAS ITk detector being developed as part of the High-Luminosity LHC upgrade. In pre-production testing, a subtle design flaw was uncovered in the…
The Forward Silicon Tracker (FST) is a pivotal component of the forward upgrade of the Solenoidal Tracker at RHIC (STAR), designed to discern hadron charge signs with a momentum resolution better than 30% for $0.2 < p_T < 2$ GeV/c in the…
The Large High Altitude Air Shower Observatory (LHAASO) is designed for high energy gamma ray and cosmic ray detection. A Water Cherenkov Detector Array which is sensitive to gamma ray showers above a few hundred GeV is proposed to survey…
Currently, there is a high interest in Lu-177 targeted radionuclide therapies, which could be attributed to favourable results obtained from Lu-177 compounds targeting neuroendocrine and prostate tumours. Generally, it has been recognized…
To cope with environments with high levels of radiation, non-silicon semiconductors such as silicon carbide detectors are being proposed for instrumentation. 4H-SiC diodes for radiation detection have been fabricated in the IMB-CNM Clean…
We recently proposed a new approach for the real-time monitoring of particle therapy treatments with the goal of achieving high sensitivities on the particle range measurement already at limited counting statistics. This method extends the…
In this article we explore the angular resolution limits attainable in small FDIRC designs taking advantage of the new highly pixelated detectors that are now available. Since the basic FDIRC design concept attains its particle separation…
A 100um thick silicon detector with 1mm2 pad readout optimized for sub-nanosecond time resolution has been developed and tested. Coupled to a purposely developed amplifier based on SiGe HBT technology, this detector was characterized at the…
A front-end readout system with a large dynamic range is required for the high-granularity crystal electromagnetic calorimeter (ECAL) at future Higgs factories. A new commercially available ASIC, MPT2321, which offers a significantly large…
We present LUCAS (Low power Ultra-low jitter Compact ASIC for SiPM), an analog front-end for Silicon Photomultipliers (SiPM) targeting fast timing detectors in Time-of-Flight Computed Tomography (ToF-CT). LUCAS features a very low input…