相关论文: Study experimental time resolution limits of recen…
The design and evaluation on the NSLS-II beamline of the 3FI application specific integrated circuit (ASIC) bump-bonded to a simply, planar, two-dimensionally segmented silicon sensor is presented. The ASIC was developed for Full-Field…
The light yield, the time resolution and the efficiency of different types of scintillating tiles with direct Silicon Photomultiplier readout and instrumented with a customised front-end electronics have been measured at the Beam Test…
Objective: This paper introduces a novel PET imaging methodology called 3-dimensional positron imaging (3D{\pi}), which integrates total-body (TB) coverage, time-of-flight (TOF) technology, ultra-low dose imaging capabilities, and…
The Low Gain Avalanche Diodes (LGADs) are promising particle detectors for timing resolution better than $50$ ps under a high radiation environment. This study investigates n-in-p LGAD architecture, focusing on ultra-thin sensors of…
Inverse synthetic aperture radar (ISAR) super-resolution imaging technology is widely applied in space target imaging. However, the performance limits of super-resolution imaging algorithms remain a rarely explored issue. This paper…
Silicon Photo-Multipliers (SiPM) are becoming the photo-detector of choice for increasingly more particle detection applications, from fundamental physics to medical and societal applications. One major consideration for their use at…
SiGe BiCMOS technology can be used to produce ultra-fast, low-power silicon pixel sensors that provide state-of-the-art time resolution even without an internal gain mechanism. The development of such sensors requires the identification of…
In order to test the performance of detector/prototype in environment of laboratory, we design and build a larger area ($90\times52$ $cm^2$) test platform of cosmic ray based on well-designed Multi-gap Resistive Plate Chamber (MRPC) with an…
We address the determination of the time resolution for the $\rm 100~\mu m$ 4H-SiC PIN detectors fabricated by Nanjing University (NJU). The time response to $\rm \beta$ particles from a $\rm ^{90}$Sr source is investigated for the…
A front end ASIC has been designed to equip the {\mu}TPC prototype developed for the MIMAC project, which requires 3D reconstruction of low energy particle tracks in order to perform directional detection of galactic Dark Matter. Each ASIC…
We investigate novel strategies to extend the sensitivity of dark matter direct detection experiments to energy deposits well below the thresholds of conventional detectors. In liquid-argon time-projection chambers equipped with silicon…
This paper presents a small-area monolithic pixel detector ASIC designed in 130 nm SiGe BiCMOS technology for the upgrade of the pre-shower detector of the FASER experiment at CERN. The purpose of this prototype is to study the integration…
Biological tissue imaging by secondary ion mass spectrometry has seen rapid development with the commercial availability of polyatomic primary ion sources. Endogenous lipids and other small bio-molecules can now be routinely mapped on the…
The TT-PET collaboration is developing a small animal TOF-PET scanner based on monolithic silicon pixel sensors in SiGe BiCMOS technology. The demonstrator chip, a small-scale version of the final detector ASIC, consists of a 3 x 10 pixel…
Verification of patient specific proton stopping powers obtained in the patient treatment position can be used to reduce the distal margins needed in particle beam planning. Proton radiography can be used as a pre-treatment instrument to…
This review traces the evolution of precision timing in particle physics experiments, from the first large-scale applications of scintillator and photomultiplier tube (PMT) systems in the 1990s to the picosecond-precision detectors of…
High-granularity homogeneous electromagnetic calorimeters based on scintillating crystals and silicon photomultipliers (SiPMs) are a promising option for future $e^{+}e^{-}$ Higgs factories, where both excellent energy resolution and a very…
A front-end readout electronics system has been developed for silicon strip detectors. The system uses an application specific integrated circuit (ASIC) ATHED to realize multi-channel E&T measurement. The slow control of ASIC chips is…
In order to improve the particle identification capability of the Beijing Spectrometer III (BESIII),t is proposed to upgrade the current endcap time-of-flight (ETOF) detector with multi-gap resistive plate chamber (MRPC) technology. Aiming…
We theoretically propose a new method in cavity- and surface-enhanced Raman spectroscopy (SERS) with improved temporal resolution in the measurement of stochastic Raman spectral fluctuations. Our approach combines Fourier spectroscopy and…