中文
相关论文

相关论文: Study experimental time resolution limits of recen…

200 篇论文

This work presents the 8-channel FastIC+, a low-power consumption and highly configurable multi-channel front-end ASIC with internal digitization, for the readout of photo-sensors with picosecond time resolution and intrinsic gain. This…

The detector of TRopIcal DEep-sea Neutrino Telescope (TRIDENT) will use large-area silicon photomultiplier (SiPM) arrays combined with photomultiplier tubes to boost photon detection efficiency and pointing capability. An…

仪器与探测器 · 物理学 2025-02-06 M. X. Wang , Y. Liu , Y. Q. Tan , J. N. Tang , W. H. Wu , D. L. Xu , W. Zhi , Z. Z. Zhou

The potential of photon detectors to achieve precise timing information is of increasing importance in many domains, PET and CT scanners in medical imaging and particle physics detectors, amongst others. The goal to increase by an order of…

仪器与探测器 · 物理学 2021-01-11 S. Enoch , A. Gola , P. Lecoq , A. Rivetti

The aim of this work is to show the potential capabilities of monolithic crystals coupled to large SiPM arrays, to be considered as detector blocks for PET scanners enabling Time Of Flight (TOF) capabilities. Monolithic blocks allow one to…

Aiming to measure the difference in arrival times of two coincident gamma-photons with an accuracy in the order of 200 ps, time-of-flight positron emission tomography systems commonly employ silicon photomultipliers (SiPMs) and…

医学物理 · 物理学 2021-02-11 Vanessa Nadig , David Schug , Bjoern Weissler , Volkmar Schulz

Coincidence time resolution (CTR) in time-of-flight positron emission tomography (TOF-PET) has significantly improved with advancements in scintillators, photodetectors, and readout electronics. Achieving a CTR of 100 ps remains challenging…

仪器与探测器 · 物理学 2024-12-25 Yuya Onishi , Ryosuke Ota

For a first characterization, we used the two KETEK-PM3325-WB SiPMs each equipped with a 3x3x5 mm${}^3$ LYSO scintillation crystal provided with the PETsys TOFPET2 ASIC Evaluation Kit. We changed the lower of two discriminator thresholds…

仪器与探测器 · 物理学 2018-12-05 David Schug , Vanessa Nadig , Bjoern Weissler , Pierre Gebhardt , Volkmar Schulz

TRopIcal DEep-sea Neutrino Telescope (TRIDENT) plans to incorporate silicon photomultipliers (SiPMs) with superior time resolution in addition to photomultiplier tubes (PMTs) into its detection units, namely hybrid Digital Optical Modules…

仪器与探测器 · 物理学 2024-06-10 Wei Zhi , Ruike Cao , Jiannan Tang , Mingxin Wang , Yongqi Tan , Weihao Wu , Donglian Xu

The time resolution of the second monolithic silicon pixel prototype produced for the MONOLITH H2020 ERC Advanced project was studied using a femtosecond laser. The ASIC contains a matrix of hexagonal pixels with 100 {\mu}m pitch, readout…

PARISROC is a complete read out chip, in AMS SiGe 0.35 micron technology [1], for photomultipliers array. It allows triggerless acquisition for next generation neutrino experiments and it belongs to an R&D program funded by the French…

Recent tests of a single module of the Jagiellonian Positron Emission Tomography system (J-PET) consisting of 30 cm long plastic scintillator strips have proven its applicability for the detection of annihilation quanta (0.511 MeV) with a…

This paper describes the characterization of crystal matrices and silicon photomultiplier arrays for a novel Positron Emission Tomography (PET) detector, namely the external plate of the EndoTOFPET-US system. The EndoTOFPET-US collaboration…

This work explores the combination of liquid xenon as a scintillating medium and silicon photomultipliers as a readout in Positron Emission Tomography (PET) for enhanced Time-Of-Flight resolution. We present the results of our first…

An ASIC named CATIROC (Charge And Time Integrated Read Out Chip) has been developed for the next-generation neutrino experiments using a large number of photomultiplier tubes (PMTs). Each CATIROC provides the time and the charge…

This paper presents the design, implementation, and performance evaluation of LUCAS, a low-power, ultra-low jitter ASIC optimized for SiPM readout in Time-of-Flight Computed Tomography (ToF-CT) applications. Leveraging a novel preamplifier…

信号处理 · 电气工程与系统科学 2025-02-06 Seyed Arash Katourani

In recent years, SiPM photoelectric devices have drawn much attention in the domain of time-of-flight-based positron emission tomography (TOF-PET). Using them to construct PET detectors with excellent coincidence time resolution (CTR) is…

仪器与探测器 · 物理学 2018-06-08 Liwei Wang , Yonggang Wang , Qiang Cao , Yong Xiao , Chong Liu

PARISROC is a complete read out chip, in AMS SiGe 0.35 !m technology, for photomultipliers array. It allows triggerless acquisition for next generation neutrino experiments and it belongs to an R&D program funded by the French national…

This paper presents the design and characterisation of a front-end prototype ASIC for the ATLAS High Granularity Timing Detector, which is planned for the High-Luminosity phase of the LHC. This prototype, called ALTIROC1, consists of a…

The Large High Altitude Air Shower Observatory (LHAASO) project has been proposed for the survey and study of cosmic rays. In the LHAASO project, the Water Cherenkov Detector Array (WCDA) is one of major detectors for searching gamma ray…

仪器与探测器 · 物理学 2016-01-20 Weihao Wu , Lei Zhao , Yu Liang , Li Yu , Jianfeng Liu , Shubin Liu , Qi An

LaBr3:Ce crystals have good scintillation properties for X-ray spectroscopy. Initially, they were introduced for radiation imaging in medical physics with either a photomultiplier or SiPM readout, and they found extensive applications in…

仪器与探测器 · 物理学 2023-11-29 M. Bonesini , R. Bertoni , A. Abba , F. Caponio , M. C. Prata , M. Rossella
‹ 上一页 1 2 3 10 下一页 ›