相关论文: Study experimental time resolution limits of recen…
The time resolution (TR) is one of the most important characteristic of a detector. For the case of a scintillator, the collection of light also is important, it depends of the effective area of the photo-sensor (\textit{Scorer}). The…
The design of a detector system comprised of four silicon sensors bump-bonded to Timepix4 ASICs is described together with its data acquisition system, operational infrastructure, and dedicated software. The spatial and temporal performance…
Silicon photomultipliers are increasingly replacing photomultiplier tubes in Cherenkov telescope cameras, but achieving single-photoelectron resolution with nanosecond timing in a low-noise, scalable detector system remains challenging. We…
The Cherenkov Imaging Telescope Integrated Read Out Chip, CITIROC, is a chip adopted as the front-end of the camera at the focal plane of the imaging Cherenkov ASTRI dual-mirror small size telescope (ASTRI SST-2M) prototype. This paper…
LaB$_3$:Ce crystals have been introduced for radiation imaging in medical physics, with photomultiplier or single SiPM readout. An R-D was pursued with 1/2" and 1" LaBr3:Ce crystals, from different producers, to realize compact large area…
The measurement of the time of flight of the two 511 keV gammas recorded in coincidence in a PET scanner provides an effective way of reducing the random background and therefore increases the scanner sensitivity, provided that the…
We present the final results from a novel Cherenkov imaging detector called the Focusing DIRC (FDIRC). This detector was designed as a full-scale prototype of the particle identification system for the SuperB experiment [1], and comprises…
The MIP Timing Detector will provide additional timing capabilities for detection of minimum ionizing particles (MIPs) at CMS during the High Luminosity LHC era, improving event reconstruction and pileup rejection. The central portion of…
This work presents the first measurements performed on the Timespot1 ASIC. As the second prototype developed for the TimeSPOT project, the ASIC features a 32x32 channels hybrid-pixel matrix. Targeted to space-time tracking applications in…
We developed a new front-end application specific integrated circuit (ASIC) for the upgrade of the Maia x-ray microprobe. The ASIC instruments 32 configurable front-end channels that perform either positive or negative charge amplification,…
The main challenges posed by the design of future Positron Emission Tomography machines are the improvement of the spatial and timing resolution and the combined operation with magnetic resonance. The Micro Pixel Photon Counter by Hamamatsu…
A monolithic silicon pixel prototype produced for the MONOLITH ERC Advanced project was irradiated with 70 MeV protons up to a fluence of 1 x 10^16 1 MeV n_eq/cm^2. The ASIC contains a matrix of hexagonal pixels with 100 {\mu}m pitch,…
The Circular Electron-Positron Collider (CEPC), a next-generation high-luminosity collider, employs a crab waist scheme to achieve ultrahigh $5 \times 10^{34} \, \text{cm}^{-2}\text{s}^{-1}$ luminosity at Higgs mode. Owing to the extremely…
A high-granularity crystal calorimeter (HGCCAL) has been proposed for the future Circular Electron Positron Collider (CEPC). This study investigates the time resolution of various crystal - Silicon Photomultiplier (SiPM) detection units for…
We report on the design and performance of a mixed-signal application specific integrated circuit (ASIC) dedicated to avalanche photodiodes (APDs) in order to detect hard X-ray emissions in a wide energy band onboard the International Space…
The proven radiation hardness of silicon 3D devices up to fluences of $1 {\times} 10^{17}$ $n_{eq}/cm^{2}$ makes them an excellent choice for next generation trackers, providing < 10 ${\mu}m$ position resolution at a high multiplicity…
Purpose: Radiotherapy commonly relies on CT, but there is growing interest in using hybrid PET/MR. Therefore, dedicated hardware setups have been proposed for PET/MR systems which enable imaging in radiotherapy treatment position. These…
The SAMpler for PICosecond time (SAMPIC) chip has been designed by a collaboration including CEA/IRFU/SEDI, Saclay and CNRS/LAL/SERDI, Orsay. It benefits from both the quick response of a time to digital converter and the versatility of a…
A second monolithic silicon pixel prototype was produced for the MONOLITH project. The ASIC contains a matrix of hexagonal pixels with 100 {\mu}m pitch, readout by a low-noise and very fast SiGe HBT frontend electronics. Wafers with 50…
Plastic scintillators are widely used in particle detectors when precise timing information is required. As a basis for comparing different detectors we use such a characteristic as the time resolution per 1MeV detected energy, i.e. the…