相关论文: Multi-Objective PMU Allocation for Resilient Power…
Phasor Measurement Units (PMUs) are essential measuring devices for monitoring, control and protection of power systems. The objective of the optimal PMU placement (OPP) problem is to minimize the number of PMUs and select the bus locations…
To provide real-time visibility of physics-based states, phasor measurement units (PMUs) are deployed throughout power networks. PMU data enable real-time grid monitoring and control -- and are essential in transitioning to smarter grids.…
In this paper, phasor measurement unit (PMU) placement for power grid state estimation under different degrees of observability is studied. Observability degree is the depth of the buses' reachability by the placed PMUs and thus constitutes…
Phasor measurement units (PMUs) are important devices for protection, monitoring, and control of modern power systems. Unlike the supervisory control and data acquisition (SCADA) system which only measure the magnitude, PMUs can provide a…
Phasor measurement units (PMUs) provide accurate and high-fidelity measurements in order to monitor the state of the power grid and support various control and planning tasks. However, PMUs have a high installation cost prohibiting their…
This paper presents an information-theoretic approach to address the phasor measurement unit (PMU) placement problem in electric power systems. Different from the conventional 'topological observability' based approaches, this paper…
Due to the potentially severe consequences of coordinated cyber-physical attacks (CCPA), the design of defenses has gained significant attention. A popular approach is to eliminate the existence of attacks by either securing existing…
A tri-objective optimal Micro Phasor Measurement Units ({\mu}-PMUs) Placement method is presented, with a focus on minimizing the following three parameters: i) the total number of {\mu}-PMU channels, (ii) the maximum state estimation…
The phasor measurement unit (PMU) placement problem is revisited by taking into account a stronger characterization of the electrical connectedness between various buses in the grid. To facilitate this study, the placement problem is…
This paper introduces an algorithm able to detect and localize the occurrance of a fault in an Active Distribution Network, using the measurements collected by Phasor Measurement Units (PMUs). First, a basic algorithm that works under the…
For the purpose of addressing the multi-objective optimal reactive power dispatch (MORPD) problem, a two-step approach is proposed in this paper. First of all, to ensure the economy and security of the power system, the MORPD model aiming…
In this paper, we compare four measures of the empirical observability gramian, including the determinant, the trace, the minimum eigenvalue, and the condition number, which can be used to quantify the observability of system states and to…
In this paper the empirical observability Gramian calculated around the operating region of a power system is used to quantify the degree of observability of the system states under specific phasor measurement unit (PMU) placement. An…
The Phasor measurement unit (PMU) measurements are mandatory to monitor the power system's voltage stability margin in an online manner. Monitoring is key to the secure operation of the grid. Traditionally, online monitoring of voltage…
Deep learning has emerged as an effective solution for addressing the challenges of short-term voltage stability assessment (STVSA) in power systems. However, existing deep learning-based STVSA approaches face limitations in adapting to…
Phasor Measurement Unit (PMU) technology is increasingly used for real-time monitoring applications, especially line outage detection and identification (D&I) in the power system. Current outage D&I schemes either assume a full PMU…
This paper presents an innovative approach to micro-phasor measurement unit (micro-PMU) placement in unbalanced distribution networks. The methodology accounts for the presence of single-and-two-phase laterals and acknowledges the fact that…
We consider the problem of identifying a single line outage in a power grid by using data from phasor measurement units (PMUs). When a line outage occurs, the voltage phasor of each bus node changes in response to the change in network…
Fast dynamics and transient events are becoming more and more frequent in power systems, due to the high penetration of renewable energy sources and the consequent lack of inertia. In this scenario, Phasor Measurement Units (PMUs) are…
In this paper, we study the placement of Phasor Measurement Units (PMU) for enhancing hybrid state estimation via the traditional Gauss-Newton method, which uses measurements from both PMU devices and Supervisory Control and Data…