中文
相关论文

相关论文: Deep Sinogram Completion with Image Prior for Meta…

200 篇论文

The presence of metallic implants often introduces severe metal artifacts in the X-ray CT images, which could adversely influence clinical diagnosis or dose calculation in radiation therapy. In this work, we present a novel…

图像与视频处理 · 电气工程与系统科学 2021-09-29 Lequan Yu , Zhicheng Zhang , Xiaomeng Li , Hongyi Ren , Wei Zhao , Lei Xing

Metal artifact reduction (MAR) in computed tomography (CT) is a notoriously challenging task because the artifacts are structured and non-local in the image domain. However, they are inherently local in the sinogram domain. Thus, one…

图像与视频处理 · 电气工程与系统科学 2021-03-09 Yuanyuan Lyu , Wei-An Lin , Haofu Liao , Jingjing Lu , S. Kevin Zhou

Computed tomography (CT) is an imaging modality widely used for medical diagnosis and treatment. CT images are often corrupted by undesirable artifacts when metallic implants are carried by patients, which creates the problem of metal…

图像与视频处理 · 电气工程与系统科学 2019-07-02 Wei-An Lin , Haofu Liao , Cheng Peng , Xiaohang Sun , Jingdan Zhang , Jiebo Luo , Rama Chellappa , Shaohua Kevin Zhou

Metal implants can heavily attenuate X-rays in computed tomography (CT) scans, leading to severe artifacts in reconstructed images, which significantly jeopardize image quality and negatively impact subsequent diagnoses and treatment…

医学物理 · 物理学 2021-08-11 Tao Wang , Wenjun Xia , Yongqiang Huang , Huaiqiang Sun , Yan Liu , Hu Chen , Jiliu Zhou , Yi Zhang

Metal artifact reduction (MAR) is a challenging problem in computed tomography (CT) imaging. A popular class of MAR methods replace sinogram measurements that are corrupted by metal with artificial data. While these ``projection…

医学物理 · 物理学 2021-01-27 T. Humphries , J. Wang

A conventional approach to computed tomography (CT) or cone beam CT (CBCT) metal artifact reduction is to replace the X-ray projection data within the metal trace with synthesized data. However, existing projection or sinogram completion…

图像与视频处理 · 电气工程与系统科学 2022-03-24 Haofu Liao , Wei-An Lin , Zhimin Huo , Levon Vogelsang , William J. Sehnert , S. Kevin Zhou , Jiebo Luo

Filtered back projection (FBP) is the most widely used method for image reconstruction in X-ray computed tomography (CT) scanners. The presence of hyper-dense materials in a scene, such as metals, can strongly attenuate X-rays, producing…

计算机视觉与模式识别 · 计算机科学 2019-08-02 Muhammad Usman Ghani , W. Clem Karl

Metal artifacts caused by the presence of metallic implants tremendously degrade the reconstructed computed tomography (CT) image quality, affecting clinical diagnosis or reducing the accuracy of organ delineation and dose calculation in…

During the computed tomography (CT) imaging process, metallic implants within patients often cause harmful artifacts, which adversely degrade the visual quality of reconstructed CT images and negatively affect the subsequent clinical…

图像与视频处理 · 电气工程与系统科学 2022-12-27 Hong Wang , Yuexiang Li , Haimiao Zhang , Deyu Meng , Yefeng Zheng

Recent CT Metal Artifacts Reduction (MAR) methods are often based on image-to-image convolutional neural networks for adjustment of corrupted sinograms or images themselves. In this paper, we are exploring the capabilities of a multi-domain…

计算机视觉与模式识别 · 计算机科学 2020-05-12 Artem Pimkin , Alexander Samoylenko , Natalia Antipina , Anna Ovechkina , Andrey Golanov , Alexandra Dalechina , Mikhail Belyaev

Current deep neural network based approaches to computed tomography (CT) metal artifact reduction (MAR) are supervised methods which rely heavily on synthesized data for training. However, as synthesized data may not perfectly simulate the…

图像与视频处理 · 电气工程与系统科学 2019-12-02 Haofu Liao , Wei-An Lin , Jianbo Yuan , S. Kevin Zhou , Jiebo Luo

In the presence of metal implants, metal artifacts are introduced to x-ray CT images. Although a large number of metal artifact reduction (MAR) methods have been proposed in the past decades, MAR is still one of the major problems in…

医学物理 · 物理学 2018-04-23 Yanbo Zhang , Hengyong Yu

An X-ray computed tomography (CT), metal artifact reduction (MAR) remains a major challenge because metallic implants violate standard CT forward-model assumptions, producing severe streaking and shadowing artifacts that degrade diagnostic…

图像与视频处理 · 电气工程与系统科学 2026-03-17 Hyoung Suk Park , Kiwan Jeon

Metal implants and other high-density objects in patients introduce severe streaking artifacts in CT images, compromising image quality and diagnostic performance. Although various methods were developed for CT metal artifact reduction over…

图像与视频处理 · 电气工程与系统科学 2024-01-10 Zilong Li , Qi Gao , Yaping Wu , Chuang Niu , Junping Zhang , Meiyun Wang , Ge Wang , Hongming Shan

During X-ray computed tomography (CT) scanning, metallic implants carrying with patients often lead to adverse artifacts in the captured CT images and then impair the clinical treatment. Against this metal artifact reduction (MAR) task, the…

图像与视频处理 · 电气工程与系统科学 2022-12-27 Hong Wang , Qi Xie , Yuexiang Li , Yawen Huang , Deyu Meng , Yefeng Zheng

During the process of computed tomography (CT), metallic implants often cause disruptive artifacts in the reconstructed images, impeding accurate diagnosis. Several supervised deep learning-based approaches have been proposed for reducing…

图像与视频处理 · 电气工程与系统科学 2024-01-08 Xuan Liu , Yaoqin Xie , Songhui Diao , Shan Tan , Xiaokun Liang

Computed tomography (CT) images are often severely corrupted by artifacts in the presence of metals. Existing supervised metal artifact reduction (MAR) approaches suffer from performance instability on known data due to their reliance on…

计算机视觉与模式识别 · 计算机科学 2025-12-11 Jie Wen , Chenhe Du , Xiao Wang , Yuyao Zhang

Metallic implants introduce severe artifacts in CT images, which degrades the image quality. It is an effective method to reduce metal artifacts by replacing the metal affected projection with the forward projection of a prior image. How to…

医学物理 · 物理学 2014-09-05 Yanbo Zhang , Xuanqian Mou

Computed tomography (CT) metal artifact reduction (MAR) aims to reduce the severe streaking artifacts induced by metallic implants and other high-density objects. Effective MAR generally requires both accurate artifact localization and…

计算机视觉与模式识别 · 计算机科学 2026-05-19 Zilong Li , Chenglong Ma , Yiming Lei , Yuanlin Li , Jing Han , Jiannan Liu , Huidong Xie , Junping Zhang , Yi Zhang , Hongming Shan

In computed tomography (CT), metal implants increase the inconsistencies between the measured data and the linear attenuation assumption made by analytic CT reconstruction algorithms. The inconsistencies give rise to dark and bright bands…

计算机视觉与模式识别 · 计算机科学 2018-08-07 Sungsoo Ha , Klaus Mueller
‹ 上一页 1 2 3 10 下一页 ›