中文
相关论文

相关论文: Attention Guided Metal Artifact Correction in MRI …

200 篇论文

Metal artefact reduction (MAR) techniques aim at removing metal-induced noise from clinical images. In Computed Tomography (CT), supervised deep learning approaches have been shown effective but limited in generalisability, as they mostly…

计算机视觉与模式识别 · 计算机科学 2020-04-21 Marta B. M. Ranzini , Irme Groothuis , Kerstin Kläser , M. Jorge Cardoso , Johann Henckel , Sébastien Ourselin , Alister Hart , Marc Modat

The presence of metallic implants often introduces severe metal artifacts in the X-ray CT images, which could adversely influence clinical diagnosis or dose calculation in radiation therapy. In this work, we present a novel…

图像与视频处理 · 电气工程与系统科学 2021-09-29 Lequan Yu , Zhicheng Zhang , Xiaomeng Li , Hongyi Ren , Wei Zhao , Lei Xing

Purpose To develop and evaluate a deep learning-based method (MC-Net) to suppress motion artifacts in brain magnetic resonance imaging (MRI). Methods MC-Net was derived from a UNet combined with a two-stage multi-loss function. T1-weighted…

图像与视频处理 · 电气工程与系统科学 2022-10-26 Lei Zhang , Xiaoke Wang , Michael Rawson , Radu Balan , Edward H. Herskovits , Elias Melhem , Linda Chang , Ze Wang , Thomas Ernst

Many studies have been conducted so far on image restoration, the problem of restoring a clean image from its distorted version. There are many different types of distortion which affect image quality. Previous studies have focused on…

计算机视觉与模式识别 · 计算机科学 2019-04-09 Masanori Suganuma , Xing Liu , Takayuki Okatani

Cardiovascular Magnetic Resonance (CMR) plays an important role in the diagnoses and treatment of cardiovascular diseases while motion artifacts which are formed during the scanning process of CMR seriously affects doctors to find the exact…

计算机视觉与模式识别 · 计算机科学 2019-03-01 Yunxuan Zhang , Weiliang Zhang , Qinyan Zhang , Jijiang Yang , Xiuyu Chen , Shihua Zhao

Metal implants can heavily attenuate X-rays in computed tomography (CT) scans, leading to severe artifacts in reconstructed images, which significantly jeopardize image quality and negatively impact subsequent diagnoses and treatment…

医学物理 · 物理学 2021-08-11 Tao Wang , Wenjun Xia , Yongqiang Huang , Huaiqiang Sun , Yan Liu , Hu Chen , Jiliu Zhou , Yi Zhang

In computed tomography (CT), metal implants increase the inconsistencies between the measured data and the linear attenuation assumption made by analytic CT reconstruction algorithms. The inconsistencies give rise to dark and bright bands…

计算机视觉与模式识别 · 计算机科学 2018-08-07 Sungsoo Ha , Klaus Mueller

Motion artifacts in Magnetic Resonance Imaging (MRI) are one of the frequently occurring artifacts due to patient movements during scanning. Motion is estimated to be present in approximately 30% of clinical MRI scans; however, motion has…

图像与视频处理 · 电气工程与系统科学 2024-05-29 Zhifeng Chen , Kamlesh Pawar , Kh Tohidul Islam , Himashi Peiris , Gary Egan , Zhaolin Chen

In-scanner motion degrades the quality of magnetic resonance imaging (MRI) thereby reducing its utility in the detection of clinically relevant abnormalities. We introduce a deep learning-based MRI artifact reduction model (DMAR) to…

图像与视频处理 · 电气工程与系统科学 2020-11-03 Yijun Zhao , Jacek Ossowski , Xuming Wang , Shangjin Li , Orrin Devinsky , Samantha P. Martin , Heath R. Pardoe

Motion artifacts caused by prolonged acquisition time are a significant challenge in Magnetic Resonance Imaging (MRI), hindering accurate tissue segmentation. These artifacts appear as blurred images that mimic tissue-like appearances,…

图像与视频处理 · 电气工程与系统科学 2024-12-06 Sunyoung Jung , Yoonseok Choi , Mohammed A. Al-masni , Minyoung Jung , Dong-Hyun Kim

In MRI, motion artefacts are among the most common types of artefacts. They can degrade images and render them unusable for accurate diagnosis. Traditional methods, such as prospective or retrospective motion correction, have been proposed…

图像与视频处理 · 电气工程与系统科学 2020-12-01 Soumick Chatterjee , Alessandro Sciarra , Max Dünnwald , Steffen Oeltze-Jafra , Andreas Nürnberger , Oliver Speck

Motion artefacts created by patient motion during an MRI scan occur frequently in practice, often rendering the scans clinically unusable and requiring a re-scan. While many methods have been employed to ameliorate the effects of patient…

图像与视频处理 · 电气工程与系统科学 2020-06-30 Michael Rotman , Rafi Brada , Israel Beniaminy , Sangtae Ahn , Christopher J. Hardy , Lior Wolf

CT images have been used to generate radiation therapy treatment plans for more than two decades. Dual-energy CT (DECT) has shown high accuracy in estimating electronic density or proton stopping-power maps used in treatment planning.…

图像与视频处理 · 电气工程与系统科学 2022-02-02 Tao Ge , Maria Medrano , Rui Liao , Jeffrey F. Williamson , David G. Politte , Bruce R. Whiting , Joseph A. O'Sullivan

Metallic implants introduce severe artifacts in CT images, which degrades the image quality. It is an effective method to reduce metal artifacts by replacing the metal affected projection with the forward projection of a prior image. How to…

医学物理 · 物理学 2014-09-05 Yanbo Zhang , Xuanqian Mou

Current deep neural network based approaches to computed tomography (CT) metal artifact reduction (MAR) are supervised methods which rely heavily on synthesized data for training. However, as synthesized data may not perfectly simulate the…

图像与视频处理 · 电气工程与系统科学 2019-12-02 Haofu Liao , Wei-An Lin , Jianbo Yuan , S. Kevin Zhou , Jiebo Luo

In computed tomography (CT), the presence of metallic implants in patients often leads to disruptive artifacts in the reconstructed images, hindering accurate diagnosis. Recently, a large amount of supervised deep learning-based approaches…

图像与视频处理 · 电气工程与系统科学 2024-06-21 Xinquan Yang , Guanqun Zhou , Wei Sun , Youjian Zhang , Zhongya Wang , Jiahui He , Zhicheng Zhang

Purpose: Deep learning-based MRI artifact correction methods often demonstrate poor generalization to clinical data. This limitation largely stems from the inability of deep learning models in reliably distinguishing motion artifacts from…

计算机视觉与模式识别 · 计算机科学 2026-04-21 Ziheng Guo , Danqun Zheng , Shuai Li , Chengwei Chen , Boyang Pan , Xuezhou Li , Ziqin Yu , Langdi Zhong , Chenwei Shao , Yun Bian , Nan-Jie Gong

Magnetic Resonance Imaging generally requires long exposure times, while being sensitive to patient motion, resulting in artifacts in the acquired images, which may hinder their diagnostic relevance. Despite research efforts to decrease the…

图像与视频处理 · 电气工程与系统科学 2025-02-04 Paolo Angella , Vito Paolo Pastore , Matteo Santacesaria

During X-ray computed tomography (CT) scanning, metallic implants carrying with patients often lead to adverse artifacts in the captured CT images and then impair the clinical treatment. Against this metal artifact reduction (MAR) task, the…

图像与视频处理 · 电气工程与系统科学 2022-12-27 Hong Wang , Qi Xie , Yuexiang Li , Yawen Huang , Deyu Meng , Yefeng Zheng

Metal artifacts, caused by high-density metallic implants in computed tomography (CT) imaging, severely degrade image quality, complicating diagnosis and treatment planning. While existing deep learning algorithms have achieved notable…

计算机视觉与模式识别 · 计算机科学 2025-08-15 Farid Tasharofi , Fuxin Fan , Melika Qahqaie , Mareike Thies , Andreas Maier
‹ 上一页 1 2 3 10 下一页 ›