中文
相关论文

相关论文: Image Quality Assessment for Rigid Motion Compensa…

200 篇论文

Incorporating computed tomography (CT) reconstruction operators into differentiable pipelines has proven beneficial in many applications. Such approaches usually focus on the projection data and keep the acquisition geometry fixed. However,…

Deep-neural-network-based image reconstruction has demonstrated promising performance in medical imaging for under-sampled and low-dose scenarios. However, it requires large amount of memory and extensive time for the training. It is…

计算机视觉与模式识别 · 计算机科学 2019-06-12 Dufan Wu , Kyungsang Kim , Quanzheng Li

The cone beam computed tomography (CBCT) technique was first inserted in dental imaging 15 years ago. Due to this technique 3D imaging in dentistry has been excessively changed. The purpose beyond using CBCT instead of computed tomography…

医学物理 · 物理学 2018-12-11 Kaspar Höschel , Janos Juhasz

Motion-compensated MR reconstruction (MCMR) is a powerful concept with considerable potential, consisting of two coupled sub-problems: Motion estimation, assuming a known image, and image reconstruction, assuming known motion. In this work,…

图像与视频处理 · 电气工程与系统科学 2022-09-09 Jiazhen Pan , Daniel Rueckert , Thomas Küstner , Kerstin Hammernik

Computed tomography (CT) is a widely used medical imaging technique to scan internal structures of a body, typically involving collimation and mechanical rotation. Compton scatter tomography (CST) presents an interesting alternative to…

图像与视频处理 · 电气工程与系统科学 2024-06-06 Ishak Ayad , Cécilia Tarpau , Javier Cebeiro , Maï K. Nguyen

Motion artifacts often spoil the radiological interpretation of MR images, and in the most severe cases the scan needs be repeated, with additional costs for the provider. We discuss the application of a novel 3D retrospective rigid motion…

图像与视频处理 · 电气工程与系统科学 2023-01-04 Gabrio Rizzuti , Tim Schakel , Niek R. F. Huttinga , Jan Willem Dankbaar , Tristan van Leeuwen , Alessandro Sbrizzi

In this paper, an automatic algorithm aimed at volumetric segmentation of acute ischemic stroke lesion in non-contrast computed tomography brain 3D images is proposed. Our deep-learning approach is based on the popular 3D U-Net…

图像与视频处理 · 电气工程与系统科学 2023-10-31 A. V. Dobshik , S. K. Verbitskiy , I. A. Pestunov , K. M. Sherman , Yu. N. Sinyavskiy , A. A. Tulupov , V. B. Berikov

Motion artifacts can compromise the diagnostic value of computed tomography (CT) images. Motion correction approaches require a per-scan estimation of patient-specific motion patterns. In this work, we train a score-based model to act as a…

计算机视觉与模式识别 · 计算机科学 2024-04-24 Mareike Thies , Noah Maul , Siyuan Mei , Laura Pfaff , Nastassia Vysotskaya , Mingxuan Gu , Jonas Utz , Dennis Possart , Lukas Folle , Fabian Wagner , Andreas Maier

Magnetic Resonance Imaging allows high resolution data acquisition with the downside of motion sensitivity due to relatively long acquisition times. Even during the acquisition of a single 2D slice, motion can severely corrupt the image.…

数值分析 · 数学 2024-04-12 Mathias S. Feinler , Bernadette N. Hahn

We present an effective post-processing method to reduce the artifacts from sparsely reconstructed cone-beam CT (CBCT) images. The proposed method is based on the state-of-the-art, image-to-image generative models with a perceptual loss as…

计算机视觉与模式识别 · 计算机科学 2018-12-11 Haofu Liao , Zhimin Huo , William J. Sehnert , Shaohua Kevin Zhou , Jiebo Luo

Contrast resolution beyond the limits of conventional cone-beam CT (CBCT) systems is essential to high-quality imaging of the brain. We present a deep learning reconstruction method (dubbed DL-Recon) that integrates physically principled…

X-ray computed tomographic infrastructures are medical imaging modalities that rely on the acquisition of rays crossing examined objects while measuring their intensity decrease. Physical measurements are post-processed by mathematical…

图像与视频处理 · 电气工程与系统科学 2022-01-25 Attila Juhos

Reconstructing a dynamic object with affine motion in computerized tomography (CT) leads to motion artifacts if the motion is not taken into account. In most cases, the actual motion is neither known nor can be determined easily. As a…

数值分析 · 数学 2024-03-14 Gesa Sarnighausen , Anne Wald , Alexander Meaney

Optical coherence tomography (OCT) is a micrometer-scale, volumetric imaging modality that has become a clinical standard in ophthalmology. OCT instruments image by raster-scanning a focused light spot across the retina, acquiring…

图像与视频处理 · 电气工程与系统科学 2022-09-16 Stefan Ploner , Siyu Chen , Jungeun Won , Lennart Husvogt , Katharina Breininger , Julia Schottenhamml , James Fujimoto , Andreas Maier

Intravital X-ray microscopy (XRM) in preclinical mouse models is of vital importance for the identification of microscopic structural pathological changes in the bone which are characteristic of osteoporosis. The complexity of this method…

The purpose of this study is to develop a deep learning based method that can automatically generate segmentations on cone-beam CT (CBCT) for head and neck online adaptive radiation therapy (ART), where expert-drawn contours in planning CT…

医学物理 · 物理学 2021-02-02 Xiao Liang , Howard Morgan , Dan Nguyen , Steve Jiang

In conventional 2D DCE-US, motion correction algorithms take advantage of accompanying side-by-side anatomical Bmode images that contain time-stable features. However, current commercial models of 3D DCE-US do not provide side-by-side Bmode…

Reconstructing dynamic, time-varying scenes with computed tomography (4D-CT) is a challenging and ill-posed problem common to industrial and medical settings. Existing 4D-CT reconstructions are designed for sparse sampling schemes that…

图像与视频处理 · 电气工程与系统科学 2021-04-26 Albert W. Reed , Hyojin Kim , Rushil Anirudh , K. Aditya Mohan , Kyle Champley , Jingu Kang , Suren Jayasuriya

Current state-of-the-art motion-based dynamic computed tomography reconstruction techniques estimate the deformation by considering motion models in the entire object volume although occasionally the proper change is local. In this article,…

最优化与控制 · 数学 2023-09-06 Anh-Tuan Nguyen , Jens Renders , Jan Sijbers , Jan De Beenhouwer

Circular cone-beam (CCB) Computed Tomography (CT) has become an integral part of industrial quality control, materials science and medical imaging. The need to acquire and process each scan in a short time naturally leads to trade-offs…

图像与视频处理 · 电气工程与系统科学 2020-10-02 Marinus J. Lagerwerf , Daniel M Pelt , Willem Jan Palenstijn , K Joost Batenburg