中文
相关论文

相关论文: Photo-acoustic tomographic image reconstruction fr…

200 篇论文

In photoacoustic tomography (PAT), a hybrid imaging modality that is based on the acoustic detection of optical absorption from biological tissue exposed to a pulsed laser, a short pulse laser generates an initial pressure proportional to…

数值分析 · 数学 2026-03-27 Sunghwan Moon , Anwesa Dey , Souvik Roy

Motion, e.g., due to patient movement or improper device calibration, is inevitable in many imaging modalities such as photoacoustic tomography (PAT) by a rotating system and can lead to undesirable motion artifacts in image…

数值分析 · 数学 2016-09-28 Julianne Chung , Linh Nguyen

We describe and examine an algorithm for tomographic image reconstruction where prior knowledge about the solution is available in the form of training images. We first construct a nonnegative dictionary based on prototype elements from the…

计算机视觉与模式识别 · 计算机科学 2015-08-18 Sara Soltani , Martin S. Andersen , Per Christian Hansen

We consider image reconstruction in full-field photoacoustic tomography, where 2D projections of the full 3D acoustic pressure distribution at a given time T>0 are collected. We discuss existing results on the stability and uniqueness of…

数值分析 · 数学 2024-12-20 Markus Haltmeier , Gerhard Zangerl , Robert Nuster , Linh V. Nguyen

The development of fast and accurate image reconstruction algorithms is a central aspect of computed tomography. In this paper, we investigate this issue for the sparse data problem in photoacoustic tomography (PAT). We develop a direct and…

计算机视觉与模式识别 · 计算机科学 2018-08-31 Stephan Antholzer , Markus Haltmeier , Johannes Schwab

In photoacoustic tomography (PAT), the computation of the initial pressure distribution within an object from its time-dependent boundary measurements over time is considered. This problem can be approached from two well-established points…

数值分析 · 数学 2025-07-04 Jaakko Kultima , Ronny Ramlau , Teemu Sahlström , Tanja Tarvainen

Photoacoustic computed tomography (PACT) is an emerging computed imaging modality that exploits optical contrast and ultrasonic detection principles to form images of the absorbed optical energy density within tissue. If the object…

医学物理 · 物理学 2017-09-08 Joemini Poudel , Thomas P. Matthews , Lei Li , Mark A. Anastasio , Lihong V. Wang

Regularization methods are commonly used in X-ray CT image reconstruction. Different regularization methods reflect the characterization of different prior knowledge of images. In a recent work, a new regularization method called a…

医学物理 · 物理学 2017-04-18 Wenxiang Cong , Ge Wang , Qingsong Yang , Jiang Hsieh , Jia Li , Rongjie Lai

Current 3D photoacoustic tomography (PAT) systems offer either high image quality or high frame rates but are not able to deliver high spatial and temporal resolution simultaneously, which limits their ability to image dynamic processes in…

Photoacoustic tomography is a hybrid biomedical technology, which combines the advantages of acoustic and optical imaging. However, for the conventional image reconstruction method, the image quality is affected obviously by artifacts under…

图像与视频处理 · 电气工程与系统科学 2024-06-26 Bowei Yao , Yi Zeng , Haizhao Dai , Qing Wu , Youshen Xiao , Fei Gao , Yuyao Zhang , Jingyi Yu , Xiran Cai

Photoacoustic tomography (PAT) is an emerging imaging modality that combines the complementary strengths of optical contrast and ultrasonic resolution. A central task is image reconstruction, where measured acoustic signals are used to…

计算机视觉与模式识别 · 计算机科学 2026-04-20 Markus Haltmeier , Nadja Gruber , Gyeongha Hwang

This work is concerned with the recovery of piecewise constant images from noisy linear measurements. We study the noise robustness of a variational reconstruction method, which is based on total (gradient) variation regularization. We show…

数值分析 · 数学 2025-07-08 Yohann De Castro , Vincent Duval , Romain Petit

Photoacoustic computed tomography (PACT) is an emerging computed imaging modality that exploits optical contrast and ultrasonic detection principles to form images of the absorbed optical energy density within tissue. When the imaging…

医学物理 · 物理学 2016-11-15 Qiwei Sheng , Kun Wang , Thomas P. Matthews , Jun Xia , Liren Zhu , Lihong V. Wang , Mark A. Anastasio

Photo-acoustic tomography (PAT) aims to leverage the photo-acoustic coupling between optical absorption of light sources and ultrasound (US) emission to obtain high contrast reconstructions of optical parameters with the high resolution of…

偏微分方程分析 · 数学 2016-09-21 Guillaume Bal , Amir Moradifam

Proper regularization is crucial in inverse problems to achieve high-quality reconstruction, even with an ill-conditioned measurement system. This is particularly true for three-dimensional photoacoustic tomography, which is computationally…

最优化与控制 · 数学 2024-09-26 Chao Wang , Alexandre H. Thiery

Non-smooth regularization is widely used in image reconstruction to eliminate the noise while preserving subtle image structures. In this work, we investigate the use of proximal Newton (PN) method to solve an optimization problem with a…

信号处理 · 电气工程与系统科学 2019-12-05 Tao Ge , Umberto Villa , Ulugbek S. Kamilov , Joseph A. O'Sullivan

Photoacoustic (PA) imaging technology combines the advantages of optical imaging and ultrasound imaging, showing great potential in biomedical applications. Many preclinical studies and clinical applications urgently require fast,…

图像与视频处理 · 电气工程与系统科学 2024-08-13 Yuwei Zheng , Zijian Gao , Yuting Shen , Jiadong Zhang , Daohuai Jiang , Fengyu Liu , Feng Gao , Fei Gao

Curvelet frame is of special significance for photoacoustic tomography (PAT) due to its sparsifying and microlocalisation properties. We derive a one-to-one map between wavefront directions in image and data spaces in PAT which suggests…

计算机视觉与模式识别 · 计算机科学 2021-08-09 Bolin Pan , Simon R. Arridge , Felix Lucka , Ben T. Cox , Nam Huynh , Paul C. Beard , Edward Z. Zhang , Marta M. Betcke

Photoacoustic computed tomography (PACT) is a non-invasive imaging modality, similar to ultrasound, with wide-ranging medical applications. Conventional PACT images are degraded by wavefront distortion caused by the heterogeneous speed of…

图像与视频处理 · 电气工程与系统科学 2025-08-05 Tianao Li , Manxiu Cui , Cheng Ma , Emma Alexander

Photoacoustic tomography (PAT) is a rapidly-evolving medical imaging modality that combines optical absorption contrast with ultrasound imaging depth. One challenge in PAT is image reconstruction with inadequate acoustic signals due to…