中文
相关论文

相关论文: Characterization of a scintillating lithium glass …

200 篇论文

This paper summarizes the results from measurements aiming to characterize ultracold neutron detection with 6Li-doped glass scintillators. Single GS10 or GS20 scintillators, with a thickness of 100-200 micrometer, fulfill the ultracold…

A novel composite, scintillating material intended for neutron detection and composed of small (1.5 mm) cubes of KG2-type lithium glass embedded in a matrix of scintillating plastic has been developed in the form of a 2.2 in.-diameter, 3.1…

仪器与探测器 · 物理学 2015-05-27 G. C. Rich , K. Kazkaz , H. P. Martinez , T. Gushue

Ultracold neutron (UCN) detectors using two visually very similar, to the microscopic level, pieces of optically contacted Cerium doped lithium glasses have been proposed for high rate UCN experiments. The chief difference between the two…

仪器与探测器 · 物理学 2015-05-11 Blair Jamieson , Lori Rebenitsch

We report on a comparison study of the $^{3}$He gas proportional tube and the $^{6}$Li incorporated scintillation glasses on thermal neutron detection efficiency. Both $^{3}$He and $^{6}$Li are used commonly for thermal neutron detection…

仪器与探测器 · 物理学 2015-06-15 Ming Xu , Zhi-Cheng Tang , Guo-Ming Chen , Jun-Quan Tao

The response of a position-sensitive Li-glass scintillator detector being developed for thermal-neutron detection with 6 mm position resolution has been investigated using collimated beams of thermal neutrons. The detector was moved…

In order to develop a high spatial resolution (micron level) thermal neutron detector, a detector assembly composed of cerium doped lithium glass microfibers, each with a diameter of 1\,$\mu$m, is proposed, where the neutron absorption…

仪器与探测器 · 物理学 2016-06-14 Song Yushou , Joseph Conner , Xiaodong Zhang , Jason P. Hayward

A construction of a thermal neutron testing detector with a thin [ZnS(Ag)+$^6$LiF] scintillator is described. Results of an investigation of sources of the detector pulse origin and the pulse features in a ground and underground conditions…

The characterization of a liquid scintillator incorporating an aqueous solution of enriched lithium chloride to produce a scintillator with 0.40% Li-6 is presented, including the performance of the scintillator in terms of its optical…

仪器与探测器 · 物理学 2013-04-23 C. D. Bass , E. J. Beise , H. Breuer , C. R. Heimbach , T. Langford , J. S. Nico

A thermal neutron detector based on ZnS(Ag)/6LiF scintillator, wavelength-shifting fibers (WLS) and silicon photomultipliers (SiPM) is under development at the Paul Scherrer Institute (PSI) for upgrading the POLDI instrument, a…

仪器与探测器 · 物理学 2015-06-17 J. -B. Mosset , A. Stoykov , V. Davydov , M. Hildebrandt , H. Van Swygenhoven , W. Wagner

The neutron detection efficiency of a sampling calorimeter made of 1 mm diameter scintillating fibers embedded in a lead/bismuth structure has been measured at the neutron beam of the The Svedberg Laboratory at Uppsala. A significant…

The next generation of very-short-baseline reactor experiments will require compact detectors operating at surface level and close to a nuclear reactor. This paper presents a new detector concept based on a composite solid scintillator…

We report on the development of a fast neutron detector using a liquid scintillator doped with enriched Li-6. The lithium was introduced in the form of an aqueous LiCl micro-emulsion with a di-isopropylnaphthalene-based liquid scintillator.…

Thermal detectors have recently achieved a leading position in the fields of neutrinoless double beta decay and dark matter searches thanks to excellent energy resolution and numerous absorber material choices. These detectors operate at…

仪器与探测器 · 物理学 2011-03-29 Carlo Bucci , Paolo Gorla , Wolfgang Seidel

The demand for new thermal neutron detectors as an alternative to 3He tubes in research, industrial, safety and homeland security applications, is growing. These needs have triggered research and development activities about new generations…

仪器与探测器 · 物理学 2018-01-09 Paolo Finocchiaro , Luigi Cosentino , Sergio Lo Meo , Ralf Nolte , Desiree Radeck

This Thesis present the process of development very low sensitivity to background radiation n-g scintillation detectors with close to 100% efficiency to corpuscular diagnostic of thermonuclear plasma. The detectors developed using this…

仪器与探测器 · 物理学 2018-01-08 F. Garcia

We present the new spectrometer for the neutron electric dipole moment (nEDM) search at the Paul Scherrer Institute (PSI), called n2EDM. The setup is at room temperature in vacuum using ultracold neutrons. n2EDM features a large UCN double…

A pixel detector with high spatial resolution and temporal information for ultra-cold neutrons is developed based on a commercial CCD on which a neutron converter is attached. 10B and 6Li are tested for the neutron converter and 10B is…

仪器与探测器 · 物理学 2010-02-03 S. Kawasaki , G. Ichikawa , M. Hino , Y. Kamiya , M. Kitaguchi , S. Komamiya , T. Sanuki , S. Sonoda

The alpha decay of $\n{{}^{210}Po}$ is a dangerous background to rare event searches. Here, we describe observations related to this alpha decay in the Cryogenic Rare Event Search with Superconducting Thermometers (CRESST). We find that…

Two single channel detection units for thermal neutron detection are investigated in a neutron beam. They consist of two ZnS/${}^6$LiF scintillating layers sandwiching an array of WLS fibers. The pattern of this units can be repeated…

仪器与探测器 · 物理学 2015-06-19 J. -B. Mosset , A. Stoykov , U. Greuter , M. Hildebrandt , N. Schlumpf , H. Van Swygenhoven
‹ 上一页 1 2 3 10 下一页 ›