相关论文: Automated Instrumentation for High-Temperature See…
A simple apparatus for the measurement of Seebeck coefficient ($\alpha$) in the temperature range 300-620 K has been fabricated. Our design is appropriate for the characterization of samples with different geometries like disk and rod…
A Seebeck coefficient measurement apparatus has been designed and developed, which is very effective for accurate characterization of different type of samples in a wide temperature range (80 - 650K) simultaneously covering low as well as…
In this work, we report the fabrication of a high temperature measurement setup to measure Figure of merit (ZT). This setup facilitates the simultaneous measurement of Seebeck coefficient ({\alpha}), thermal conductivity (\kappa), and…
Fabrication and characterization of instrument for high-temperature simultaneous measurement of Seebeck coefficient (S) and thermal conductivity ($\kappa$) has been carried out with python automation. The steady-state based Fourier's law of…
A setup is designed for measuring the Seebeck coefficient (S) of materials in form of thin film, bar and wire. The main feature of this setup is control in heating and cooling cycles. In this setup heat pulse is used to generate the…
An in-house Seebeck coefficient measurement system has been developed which can measure the thermoemf (Seebeck coefficient) of the sample, under large temperature difference, in the temperature range 300-600 K. Unlike majority of reported…
In this work, we interface high temperature Z-meter setup to automize the whole measurement process. A program is built on open source programming language Python which convert the manual measurement process into fully automated process…
In this work, we report the fabrication of experimental setup for high temperature thermal conductivity ($\kappa$) measurement. It can characterize samples with various dimensions and shapes. Steady state based axial heat flow technique is…
We present the design and construction of an apparatus that measures the Seebeck coefficient of single crystals under in-situ tunable strain at cryogenic temperatures. A home-built three piezostack apparatus applies uni-axial stress to a…
This study presents a novel thermocouple instrument designed for precise temperature monitoring within biological tissues and cells, addressing a significant gap in biological research. Constructed on a Silicon-On-Insulator (SOI) substrate,…
This work builds on the previous introduction [1] of a coupled experimental-computational system devised to fully characterize the thermal behavior of complex 3D submicron electronic devices. The new system replaces the laser-based surface…
Seebeck coefficient is a widely-studied semiconductor property. Conventional Seebeck coefficient measurements are based on DC voltage measurement. Normally this is performed on samples with low resistances below a few Mohm level. Meanwhile,…
Thermoelectric materials can convert thermal energy into electricity, making them promising candidates for harvesting waste heat, an increasingly important challenge in the energy-intensive modern world. The search for improved…
The temperature dependence of the Seebeck coefficient of homoepitaxial metal organic vapor phase (MOVPE) grown, silicon doped $\beta$-Ga$_2$O$_3$ thin films was measured relative to aluminum. For room temperature we found the relative…
Heavily doped semiconductors are by far the most studied class of materials for thermoelectric applications in the past several decades. They have Seebeck coefficient values which are 2-3 orders of magnitude higher than metals, making them…
This is the report on new development of an automated precision load-based measurement setup for thermoelectric power of different types of samples in the temperature range 5 - 330 K. The problems in the old spring-based setup have been…
We have developed a method to probe the temperature of surface state electrons (SSE) above a superfluid Helium-4 surface using the Seebeck effect. In contrast to previously used SSE thermometry, this technique does not require detailed…
A simple and low cost apparatus has been designed and built to measure the electrical resistivity, ($\rho$), of metal and semiconductors in 300-620 K temperature range. The present design is suitable to do measurement on rectangular bar…
Precise temperature measurement at micro/nanoscale is crucial across various domains including physical sciences, chemical processes, industrial production, medical diagnosis, weather forecasting, electronics, and biology. Micro/nanoscale…
In a recent article [Phys. Rev. Applied 5, 024005 (2016)], Gibelli and coworkers proposed a method to determine the thermopower, i.e. the Seebeck coefficient, using photoluminescence measurements. The photoluminescence spectra are used to…