相关论文: An Optimal Energy Estimator to Reduce Correlated N…
EXO-200 is an experiment designed to search for double beta decay of $^{136}$Xe with a single-phase, liquid xenon detector. It uses an active mass of 110 kg of xenon enriched to 80.6% in the isotope 136 in an ultra-low background time…
The development prospects of a scintillator-photodiode type detector with an improved energy resolution attaining few per cent, R from 1 to 2%, are considered. The main resolution components have been analyzed theoretically, their…
Liquid xenon (LXe) is employed in a number of current and future detectors for rare event searches. We use the EXO-200 experimental data to measure the absolute scintillation and ionization yields generated by $\gamma$ interactions from…
A search for neutrinoless double-beta decay ($0\nu\beta\beta$) in $^{136}$Xe is performed with the full EXO-200 dataset using a deep neural network to discriminate between $0\nu\beta\beta$ and background events. Relative to previous…
Results from a search for neutrinoless double-beta decay $0\nu\beta\beta$ of $^{136}$Xe are presented using the first year of data taken with the upgraded EXO-200 detector. Relative to previous searches by EXO-200, the energy resolution of…
The development prospects have been considered of a scintillator-photodiode type detector with improved energy resolution attaining several per cent ($R=1-2%$). The main contributions to the scintielectron detector energy resolution have…
Searches for double beta decay of $^{134}$Xe were performed with EXO-200, a single-phase liquid xenon detector designed to search for neutrinoless double beta decay of $^{136}$Xe. Using an exposure of $29.6\text{ kg}\!\cdot\!\text{yr}$, the…
In a neutrinoless double-beta decay ($0\nu\beta\beta$) experiment, energy resolution is important to distinguish between $0\nu\beta\beta$ and background events. CAlcium fluoride for studies of Neutrino and Dark matters by Low Energy…
A photon-counting silicon strip detector with two energy thresholds was investigated for spectral X-ray imaging in a mammography system. Preliminary studies already indicate clinical benefit of the detector, and the purpose of the present…
The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber…
Xenon dual-phase time projection chambers designed to search for Weakly Interacting Massive Particles have so far shown a relative energy resolution which degrades with energy above $\sim$200 keV due to the saturation effects. This has…
The possibilty of performing high-rate calorimetry with a slow scintillator crystal is studied. In this experimental situation, to avoid pulse pile-up, it can be necessary to base the energy measurement on only a fraction of the emitted…
EXO is a search for neutrinoless double beta decay in 136Xe. An active R&D program for a 10 ton, enriched 136Xe liquid phase detector is now underway. Current research projects are: decay product extraction, Xe purity studies, energy…
A new search for two-neutrino double-beta ($2\nu\beta\beta$) decay of $^{136}\rm Xe$ to the $0^+_1$ excited state of $^{136}\rm Ba$ is performed with the full EXO-200 dataset. A deep learning-based convolutional neural network is used to…
Liquid xenon detectors such as XENON10 and XENON100 obtain a significant fraction of their sensitivity to light (<10 GeV) particle dark matter by looking for nuclear recoils of only a few keV, just above the detector threshold. Yet in this…
NEXT-100 is a high-pressure xenon time projection chamber with electroluminescent amplification, designed to operate with up to approximately 70.5 kg at 13.5 bar. It is the most recent detector developed by the NEXT collaboration to search…
The CUPID-0 experiment searches for neutrinoless double beta decay ($0\nu\beta\beta$) using the first array of enriched Zn$^{82}$Se scintillating bolometers with double (heat and light) read-out. To further enhance the CUPID-0 detector…
EXO-200 is a single phase liquid xenon detector designed to search for neutrinoless double-beta decay of $^{136}$Xe to the ground state of $^{136}$Ba. We report here on a search for the two-neutrino double-beta decay of $^{136}$Xe to the…
EXO-200 is the first phase of the Enriched Xenon Observatory (EXO) experiment, which searches for neutrinoless double beta decay in 136Xe to measure the mass and probe the Majorana nature of the neutrino. EXO-200 consists of 200 kg of…
The Enriched Xenon Observatory (EXO) will search for double beta decays of 136Xe. We report the results of a systematic study of trace concentrations of radioactive impurities in a wide range of raw materials and finished parts considered…