相关论文: An Optimal Energy Estimator to Reduce Correlated N…
This paper describes the energy scale procedures and germanium detectors performance in the LEGEND-200 experiment, a critical component for the first unblinding in the search for neutrinoless double beta decay. We detail the digital signal…
Noble liquid detectors have become an attractive option for exploring physics beyond the standard model. Current experiments are using these detectors to search for dark matter interactions, neutrinoless double beta decay, and other…
Scintillation light from gamma ray irradiation in liquid xenon is detected by two Hamamatsu R9288 photomultiplier tubes (PMTs) immersed in the liquid. UV light reflector material, PTFE, is used to optimize the light collection efficiency.…
The efficiency and energy resolution of the MAST neutron camera detectors, based on liquid scintillator of the EJ-301 type, is lower than cylindrical detector of similar size. An experimental investigation has identified light attenuation…
Discrimination of fast neutrons, thermal neutrons, and $\gamma$ rays in mixed radiation fields is important for radiation monitoring, reactor-related measurements, and background suppression in nuclear experiments. In this work, we…
Continued improvement of the energy resolution of resonant inelastic x-ray scattering (RIXS) spectrometers is crucial for fulfilling the potential of this technique in the study of electron dynamics in materials of fundamental and…
Results of observations of low energy nuclear and electron recoil events in liquid xenon scintillator detectors are given. The relative scintillation efficiency for nuclear recoils is 0.22 +/- 0.01 in the recoil energy range 40 keV - 70…
We measure the liquid argon scintillation response to electronic recoils in the energy range of $2.82$ to $1274.6~{\rm keV}$ at null electric field. The single-phase detector with a large optical coverage used in this measurement yields…
Resonant Inelastic X-ray Scattering (RIXS) in the soft x-ray range is an element-specific energy-loss spectroscopy used to probe the electronic and magnetic excitations in strongly correlated solids. In the recent years, RIXS has been…
Visibility scintillation resulting from wave propagation through the turbulent ionosphere can be an important sources of noise at low radio frequencies ($\nu\lesssim 200$ MHz). Many low frequency experiments are underway to detect the power…
Large liquid-scintillator-based detectors have proven to be exceptionally effective for low energy neutrino measurements due to their good energy resolution and scalability to large volumes. The addition of directional information using…
We report on the position, timing, and energy resolution of a range of plastic scintillator bars and reflector treatments using dual-ended silicon photomultiplier readout. These measurements are motivated by the upcoming construction of an…
This study presents a denoising algorithm trained using machine learning to improve the energy resolution of a single-phase liquid xenon time projection chamber for neutrinoless double beta decay detection. Supervised, unsupervised, and…
Liquid xenon is an important detection medium in direct dark matter experiments, which search for low-energy nuclear recoils produced by the elastic scattering of WIMPs with quarks. The two existing measurements of the relative…
We present results of several measurements of CsI[Na] scintillation response to 3-60 keV energy nuclear recoils performed by the COHERENT collaboration using tagged neutron elastic scattering experiments and an endpoint technique. Earlier…
A general formula for current noise in a two-terminal ballistic nondegenerate conductor under the action of long-range Coulomb correlations has been derived. The noise reduction factor (in respect to the uncorrelated value) is obtained for…
We investigate the precision limits and optimal protocols for sensing single qubit signals in the presence of erasure noise. We study a hierarchy of precision limits achievable with metrological strategies of differing complexity, and…
In a recent publication Larson \textit{et al.} reported remarkably clear $d$-$d$ excitations for NiO and CoO measured with x-ray energies well below the transition metal $K$ edge. In this letter we demonstrate that we can obtain an accurate…
Scintillators have been widely used in X-ray imaging due to their ability to convert high-energy radiation into visible light, making them essential for applications such as medical imaging and high-energy physics. Recent advances in the…
Energy nonlinearity and resolution in liquid scintillator (LS) detectors are correlated and particle-dependent. A unified energy response model for liquid scintillator detectors has been presented in details. This model has advanced a…