中文
相关论文

相关论文: A Model-Based Scatter Artifacts Correction for Con…

200 篇论文

We provide a fast and accurate scatter artifacts correction algorithm for cone beam CT (CBCT) imaging. The method starts with an estimation of coarse scatter profile for a set of CBCT images. A total-variation denoising algorithm designed…

医学物理 · 物理学 2015-01-20 Wei Zhao , Jun Zhu , Luyao Wang

This paper provides a fast and patient-specific scatter artifact correction method for cone-beam computed tomography (CBCT) used in image-guided interventional procedures. Due to increased irradiated volume of interest in CBCT imaging,…

医学物理 · 物理学 2015-01-20 Wei Zhao , Stephen Brunner , Kai Niu , Sebastian Schafer , Kevin Royalty , Guang-Hong Chen

In Cone-Beam CT (CBCT) imaging systems, the scattering phenomenon has a significant impact on the reconstructed image and is a long-lasting research topic on CBCT. In this paper, we propose a simple, novel and fast approach for mitigating…

医学物理 · 物理学 2016-04-07 Shi-peng Xie , Rui-ju Yan

Cone-beam CT (CBCT) employs a flat-panel detector to achieve three-dimensional imaging with high spatial resolution. However, CBCT is susceptible to scatter during data acquisition, which introduces CT value bias and reduced tissue contrast…

计算机视觉与模式识别 · 计算机科学 2025-10-29 Xu Jiang , Huiying Pan , Ligen Shi , Jianing Sun , Wenfeng Xu , Xing Zhao

Due to its wide field of view, cone-beam computed tomography (CBCT) is plagued by large amounts of scatter, where attenuated photons hit the detector, and corrupt the linear models used for reconstruction. Given that one can generate a good…

医学物理 · 物理学 2017-07-06 Jonathan Mason , Alessandro Perelli , William Nailon , Mike Davies

Purpose: Scatter artifacts drastically degrade the image quality of cone-beam computed tomography (CBCT) scans. Although deep learning-based methods show promise in estimating scatter from CBCT measurements, their deployment in mobile CBCT…

信号处理 · 电气工程与系统科学 2025-09-12 Harshit Agrawal , Ari Hietanen , Simo Särkkä

CBCT images suffer from acute shading artifacts primarily due to scatter. Numerous image-domain correction algorithms have been proposed in the literature that use patient-specific planning CT images to estimate shading contributions in…

计算机视觉与模式识别 · 计算机科学 2018-01-18 Awais Ashfaq , Jonas Adler

We present an effective post-processing method to reduce the artifacts from sparsely reconstructed cone-beam CT (CBCT) images. The proposed method is based on the state-of-the-art, image-to-image generative models with a perceptual loss as…

计算机视觉与模式识别 · 计算机科学 2018-12-11 Haofu Liao , Zhimin Huo , William J. Sehnert , Shaohua Kevin Zhou , Jiebo Luo

Deep learning based approaches have been used to improve image quality in cone-beam computed tomography (CBCT), a medical imaging technique often used in applications such as image-guided radiation therapy, implant dentistry or…

计算机视觉与模式识别 · 计算机科学 2024-03-28 Mohammadreza Amirian , Daniel Barco , Ivo Herzig , Frank-Peter Schilling

Scatter signals can degrade the contrast and resolution of computed tomography (CT) images and induce artifacts. How to effectively correct scatter signals in CT has always been a focal point of research for researchers. This work presents…

医学物理 · 物理学 2025-01-10 Guiyuan Lin , Shiwo Deng , Xiaoqun Wang , Xing Zhao

Recently, spectral CT has been drawing a lot of attention in a variety of clinical applications primarily due to its capability of providing quantitative information about material properties. The quantitative integrity of the reconstructed…

医学物理 · 物理学 2018-01-12 Shiyu Xu , Peter Prinsen , Jens Wiegert , Ravindra Manjeshwar

Background: Daily or weekly cone-beam computed tomography (CBCT) scans are commonly used for accurate patient positioning during the image-guided radiotherapy (IGRT) process, making it an ideal option for adaptive radiotherapy (ART)…

In this paper, an improved scatter correction with moving beam stop array (BSA) for x-ray cone beam (CB) CT is proposed. Firstly, correlation between neighboring CB views is deduced based on John's Equation. Then, correlation-based…

医学物理 · 物理学 2014-10-31 Hao Yan , Xuanqin Mou , Shaojie Tang , Qiong Xu

Cone Beam Computed Tomography (CBCT) is widely used in dentistry for diagnostics and treatment planning. CBCT Imaging has a long acquisition time and consequently, the patient is likely to move. This motion causes significant artifacts in…

计算机视觉与模式识别 · 计算机科学 2023-04-21 Abdul Salam Rasmi Asraf Ali , Andrea Fusiello , Claudio Landi , Cristina Sarti , Anneke Annassia Putri Siswadi

Cone-beam computed tomography (CBCT) images are problematic in clinical medicine because of their low contrast and high artifact content compared with conventional CT images. Although there are some studies to improve image quality, in…

图像与视频处理 · 电气工程与系统科学 2026-03-30 Naruki Murahashi , Mitsuhiro Nakamura , Megumi Nakao

This paper presents a two-stage method for beam hardening artifact correction of dental cone beam computerized tomography (CBCT). The proposed artifact reduction method is designed to improve the quality of maxillofacial imaging, where soft…

计算工程、金融与科学 · 计算机科学 2020-10-09 T. Bayaraa , C. M. Hyun , T. J. Jang , S. M. Lee , J. K. Seo

Cone-beam computed tomography (CBCT) is routinely collected during image-guided radiation therapy (IGRT) to provide updated patient anatomy information for cancer treatments. However, CBCT images often suffer from streaking artifacts and…

计算机视觉与模式识别 · 计算机科学 2023-11-02 Jiarui Zhu , Werxing Chen , Hongfei Sun , Shaohua Zhi , Jing Qin , Jing Cai , Ge Ren

During spinal fusion surgery, screws are placed close to critical nerves suggesting the need for highly accurate screw placement. Verifying screw placement on high-quality tomographic imaging is essential. C-arm Cone-beam CT (CBCT) provides…

计算机视觉与模式识别 · 计算机科学 2022-01-20 Mareike Thies , Jan-Nico Zäch , Cong Gao , Russell Taylor , Nassir Navab , Andreas Maier , Mathias Unberath

In computed tomography (CT) reconstruction, scattering causes server quality degradation of the reconstructed CT images by introducing streaks and cupping artifacts which reduce the detectability of low contrast objects. Monte Carlo (MC)…

图像与视频处理 · 电气工程与系统科学 2022-02-01 Ammar Alsaffar , Steffen Kieß , Kaicong Sun , Sven Simon

X-ray imaging dose from serial cone-beam CT (CBCT) scans raises a clinical concern in most image guided radiation therapy procedures. It is the goal of this paper to develop a fast GPU-based algorithm to reconstruct high quality CBCT images…

医学物理 · 物理学 2015-05-19 Xun Jia , Bin Dong , Yifei Lou , Steve B. Jiang
‹ 上一页 1 2 3 10 下一页 ›